Fig. 4 -
Model 3087ST controls shown

Fig. 3

Thermostat
Knob

Heat Selector
Switch

Digital Timer

Positioning the heater

Always ensure that the heater is stood on a firm, level base near to, but
not directly beneath, a suitable mains supply socket.
Ensure that curtains and furniture are not positioned close to the chosen
position, as this would create a potential fire hazard.
We recommend that the heater should be wall-mounted in rooms where
children may be left unattended.
See also ‘Important Safety Advice’.

Free standing use

NEVER USE THE HEATER FREE STANDING WITHOUT THE FEET FITTED.

Lay the heater on its back,
and locate the foot fixing
screw (see ‘a’ in 

Fig. 3

).

Remove the screw using  an
X–head screwdriver, then
align foot over slots and holes
in base (see ‘b’ in 

Fig. 3

) and

push into slots until the foot
clips into place. Finally take
the foot fixing screw, insert
and tighten using a
screwdriver to secure the
foot.
NOTE – The wall mounting
brackets indicated in 

Fig. 3

can be left secured to the
base if they are not required.

Using the heater

Plug in and switch on at the wall socket.
On models with a timer clock, the clock will operate all the time that the
heater is connected to the mains supply, regardless of the setting of the
heat selector switch. Set the timer control switch as required for OFF,
Manual or Automatic operation – see 

‘Timer Operations’

.

The heat output is controlled
by the thermostat - see

‘Thermostat’

.

Please note – the element has
been coated with a protective
film which will burn off during
the first few minutes of use
and may cause a small
amount of fuming. This is quite
normal – the fumes are non-
toxic and will quickly
disappear.
We recommend that you open
a window to ventilate the
room when using the heater
for the first time.

Controls

Thermostat

The thermostat controls the heat output according to the room temperature.
This ensures that the heater will not produce heat unnecessarily when
the room is warm.
To set the temperature you require, turn the thermostat knob clockwise
until the desired temperature is reached. Alternatively to heat a cold room
quickly, turn the thermostat knob up fully.
When the room has reached the desired temperature, turn the thermostat
knob anti-clockwise until the thermostat just clicks off.
The heater will now automatically operate at this temperature.
The thermostat also has a frost protection setting marked ‘*’. This setting
is useful in areas such as garages to prevent frost damage. If the
thermostat is set to its minimum setting ‘*’, the heater will cycle ON and
OFF to maintain a temperature of approximately 5°C to help protect against
frosty conditions.

Heat Selector Switch

Heat selection is available on both models as an economy feature.
On model 3088T  -  the switch is a 4 position switch with an 

Off

 position

marked 

‘O’

 and 3 possible heat settings as follows :

&

 II

- The heater operates with low heat output

III

- The heater operates with max. heat output

Foot
fixing
screw

Wall mounting
brackets

(b)

(a)

13 : 17

ON

OFF

ADVANCE

AUTO          MAN        ON        OFF

P1

On model 3088T  - the switch is a 4 position switch with an 

Off

 position

marked 

‘O’

 and 3 possible heat settings as follows :;

I

- The heater operates with 1kW output

II

- The heater operates with 2kW output

III

- The heater operates with full 3kW output

ON/OFF Switch

On model 3087ST – the switch operates as follows :

 

I

- The heater is off

 

I

 

I

- The heater operates with 2kW output

Note : The above description of the On/Off switch operation is with the
turbo neon switch in the off position – see also ‘Model 3087ST’ in the
‘Turbo Fan Models ..’ section.

Digital Timer Operation 

- see 

Fig. 5

IMPORTANT:

 Remember to observe all safety warnings when operating

the heater on auto setting, either attended or unattended.
The timer allows you to select ‘

AUTO

’ or ‘

MAN ON

’ by pressing the ‘MODE’

button until the required MODE appears at the bottom of the timer display.

AUTO

’ MODE allows the heater to switch ON and OFF according to a set

24 Hour program period (see ‘Setting Programs’ section below).

MAN ON

’ MODE allows power to the heater uninterrupted by the program

settings.
Key Lock:
If ‘

ENTER

’ and ‘

MODE

’ are pressed within 1 second, the keys will be

locked. The user will know the keys are locked as the lock symbol ‘ ’ will
be displayed on the top left hand corner of the screen. To unlock the
keypad, press ‘

ENTER

’ and then ‘

MODE

’ within 1 second.

Initial Operation

For initial use, plug the heater into a regular household power point and
turn the power on.  The timer is now ready to be set up for use.

Setting Current Time

1. Press the ‘

PROGRAM

’ button ONCE.  The clock symbol 

 appears on

the top left hand side of the screen.  The user can now set the clock.
2. The hour digit will flash. To adjust the hour use the ‘

-

‘ & ‘

+

’ buttons.

Confirm the hour digit by pressing ‘

ENTER

’.

3. Once ‘ENTER’ has been pressed the minutes will flash.  To adjust the
minutes use the ‘-‘&‘+’ buttons. Confirm the minute digit by pressing ‘ENTER’.
4. The timer now returns to the default display.
5. To reset incorrect time, repeat previous steps.
Once the correct time is set, a total of four ON/OFF time programs can be
set for operation.  There are two program options.

Setting Programmes

Press the ‘

PROGRAM

’ key twice to set the programs.

You are now setting the programs starting with P1 ‘ON’.

SETTING P1 ON TIME:

1. To set the hour use the ‘

-

‘ & ‘

+

’ buttons. Confirm the hour digit by

pressing ‘

ENTER

’.

2. To set the minutes use the ‘

-

‘ & ‘

+

’ buttons. Confirm the minute digit by

pressing ‘

ENTER

’.

Note: The minutes can only be set in 10 minute blocks in programme

MODE

’.

SETTING P1 OFF TIME:

3. To set the hour use the ‘

-

‘ & ‘

+

’ buttons. Confirm the hour digit by

pressing ‘

ENTER

’.

4. To set the minutes use the ‘

-

‘ & ‘

+

’  buttons. Confirm the minute digit by

pressing ‘

ENTER

’.

Repeat steps 1 to 4 to programme P2, P3 & P4. After programming P4 ‘OFF’
you automatically exit to the default display.
At any time while programming the timer you can press the ‘

PROGRAM

button to exit to the default display.

13 : 17

ON

OFF

ADVANCE

AUTO          MAN        ON        OFF

P1

Fig.  5

Содержание 3082S

Страница 1: ...ilarly qualified person in order to avoid a hazard For further information please contact our guard supplier direct on Tel No 01603 667957 or in case of difficulty or for further advice contact the Customer Helpline Electrical connection WARNING THIS APPLIANCE MUST BE EARTHED This heater must be used on an supply only and the voltage marked on the heater must correspond to the supply voltage This ...

Страница 2: ...rates with low heat output III The heater operates with max heat output Foot fixing screw Wall mounting brackets b a 13 17 ON OFF ADVANCE AUTO MAN ON OFF P1 On model 3088T the switch is a 4 position switch with an Off position marked O and 3 possible heat settings as follows I The heater operates with 1kW output II The heater operates with 2kW output III The heater operates with full 3kW output ON...

Страница 3: ...round the room to help it reach the desired temperature more quickly On all turbo models with the heat selector switch at max setting 3kw operation the fan automatically switches on to override the operation of the Turbo On Off neon switch This permanent operation of the fan at maximum heat setting ensures more efficient operation and heat circulation around the room Model 3088T On this model you ...

Страница 4: ... accordance with these instructions Your rights under this guarantee are additional to your statutory rights which in turn are not affected by this guarantee Should you require after sales information or assistance with this product please go to www dimplex co uk where you will find our self help guide by clicking on After Sales or ring our helpdesk on 0845 600 5111 UK or 01 842 4833 R O I Spare p...

Отзывы: