background image

Dimensions

(millimetres)

Installation and Operating Instructions

Dimplex Convector Heaters
Models : 3082S, 3087S, 3087ST and 3088T

INDCUK308R     Issue 10

Models

Specification

3082S

2.0kw

Heat Switch / Thermostat / Neon / 24hr Timer

3087S

3.0kw

Heat Switch / Thermostat / 24hr Timer

3087ST

3.0kw

On/Off Switch / Thermostat / Neon / 24hr Timer / Turbo

3088T

3.0kw

Heat Switch / Thermostat / Neon / Turbo

 

IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

432

230

777 - 3.0kW

MIN

140

230

450

357

MIN

MIN

Floor Mtd.

Wall Mtd.

657 - 2.0kW

Important Safety Advice

WARNING – THIS APPLIANCE MUST NOT BE USED IN A BATHROOM.
WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL.
WARNING – THIS HEATER MUST NOT BE LOCATED IMMEDIATELY
BELOW A FIXED SOCKET OUTLET.
DO NOT USE THE HEATER UNTIL THE FEET OR WALL BRACKETS
ARE FITTED CORRECTLY.
FOLLOW these instructions carefully.
NEVER cover or obstruct in any way the heat outlet slots at
the top of the heater or the air inlet slots in the base of the
heater.
The heater carries a warning ‘DO NOT COVER’ to alert the user
to the risk of fire that exists if the heater is accidentally
covered.
Timer models 3082S, 3087S and 3087ST can be set to switch
on automatically. Remember to observe all safety warnings
at all times.
Caution: In order to avoid a hazard due to inadvertent resetting
of the thermal cutout, this appliance must not be supplied
through an external switching device, such as a timer, or
connected to a circuit that is regularly switched on and off by
the utility.
This appliance is not intended for use by children or other
persons without assistance or supervision if their physical,
sensory or mental capabilities prevent them from using it
safely. Children should be supervised to ensure that they do
not play with the appliance.
If young children, the aged or infirm are likely to be left in the
vicinity of the heater, we advise that adequate precautions
should be taken. We recommend that a guard be fitted to
ensure contact with the heater is avoided and objects cannot
be inserted into the product.
If the mains lead is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid a hazard.
For further information, please contact our guard supplier
direct on Tel. No. 01603 667957, or in case of difficulty or for
further advice contact the Customer Helpline.

Electrical connection

WARNING – THIS APPLIANCE MUST BE EARTHED

This heater must be used on an ~ supply only and the voltage marked on
the heater must correspond to the supply voltage. This heater is fitted
with a rewireable plug incorporating a 13 amp fuse. In the event of
replacing the fuse in the plug supplied, a 13 amp fuse approved by ASTA
to BS 1362 must be used. If any other type of plug is used, a 15 amp fuse
must be fitted in the plug, the adaptor, or at the distribution board.
IMPORTANT : If the plug is not suitable for your socket, the 13 amp plug
should be removed. Before wiring the appropriate plug, please note that

the wires in this mains lead are coloured in accordance with the following
code :

GREEN AND YELLOW:

EARTH

BLUE :

NEUTRAL

BROWN :

LIVE

Connect the 

GREEN AND YELLOW

 wire to the terminal marked ‘

E

’ or by

the earth symbol 

 , or coloured 

GREEN

 or 

GREEN AND YELLOW

.

Connect the 

BROWN

 wire to the terminal marked ‘

L

’ or coloured 

RED

.

Connect the 

BLUE

 wire to the terminal marked ‘

N

’ or coloured 

BLACK.

Wall Mounting

Three identical wall mounting brackets are secured to the base of the
heater with a fixing screw. To wall mount appliance, first remove the
brackets as follows :
Lay the heater on its back.
Following the sequence in 

Fig. 1

 – identify and remove the fixing screw

securing the brackets located beside Mains Cable as shown in (a), then
pull out brackets and rotate them to disengage them from the slot (b).
Withdraw the brackets from the slot (c).

Select a suitable position on a wall, near to a mains power socket, making
sure that there is 

at least

  230 mm below the heater and 

at least

 450 mm

above the heater of unobstructed space. See also ‘Positioning the heater’.
Fix the two top retaining brackets to the wall, using suitable fixings, for
2kW models at 358mm centres and 3kW models at  478mm centres  – see

Fig. 2

.

Locate the heater on the top brackets and allow it to hang in place.
Fit the bottom bracket into the slot in the heater and then fix it to the wall.
Test that the heater is now securely fixed to the wall.

(a)

      (b)

(c)

Wall Mounting
Brackets

Fig. 1

3 No. Wall
Mounting
Brackets

shelf / 

ceiling

floor

520 mm
min.

526 mm
min.

bracket
slot

358mm centres - 2kW

478mm centres - 3kW

Fig. 2

Содержание 3082S

Страница 1: ...ilarly qualified person in order to avoid a hazard For further information please contact our guard supplier direct on Tel No 01603 667957 or in case of difficulty or for further advice contact the Customer Helpline Electrical connection WARNING THIS APPLIANCE MUST BE EARTHED This heater must be used on an supply only and the voltage marked on the heater must correspond to the supply voltage This ...

Страница 2: ...rates with low heat output III The heater operates with max heat output Foot fixing screw Wall mounting brackets b a 13 17 ON OFF ADVANCE AUTO MAN ON OFF P1 On model 3088T the switch is a 4 position switch with an Off position marked O and 3 possible heat settings as follows I The heater operates with 1kW output II The heater operates with 2kW output III The heater operates with full 3kW output ON...

Страница 3: ...round the room to help it reach the desired temperature more quickly On all turbo models with the heat selector switch at max setting 3kw operation the fan automatically switches on to override the operation of the Turbo On Off neon switch This permanent operation of the fan at maximum heat setting ensures more efficient operation and heat circulation around the room Model 3088T On this model you ...

Страница 4: ... accordance with these instructions Your rights under this guarantee are additional to your statutory rights which in turn are not affected by this guarantee Should you require after sales information or assistance with this product please go to www dimplex co uk where you will find our self help guide by clicking on After Sales or ring our helpdesk on 0845 600 5111 UK or 01 842 4833 R O I Spare p...

Отзывы: