background image

2002 Dimension One Spas Export Owner’s Manual 

 

Using the Programmable Digital Controller 

To initiate the programming sequence at any time, push and hold the Program Pad for 3 seconds. If, within 10 
seconds, you do not proceed with the hot tub programming, the hot tub will automatically exit the programming 
sequence and revert to the pre-set factory default settings. To exit the programming sequence at any time, do not 
press any pad for 10 seconds. Any programming changes made up to that point is saved. 

Clock Set 

Push and hold the Program Pad for 3 seconds to engage the time setting mode. The time screen will appear with 
“hours” (__.00) flashing on and off. Push the Up Pad or Down Pad to increase or decrease the number until the 
desired hour appears in the Digital Display. When the desired number is displayed, push the Light Pad to accept 
the selection and change the flashing number to the “ten minute”  place (12:_0). Adjust the number with the Up or 
Down Pads in the same manner as the hour number. When the desired number is displayed, push the Light Pad to 
accept the selection and change the flashing number to the “minute” place (12:1_). Adjust this number with the Up 
or Down Pad in the same manner as the hour number. When the desired number is displayed, push the Light Pad 
to accept the selection and change the flashing number to a flashing AM or PM indicator. Adjust the indicator with 
the Up and Down Pads. When the desired indicator is displayed, push the Program Pad to accept the selection and 
enter the Filter Cycle Start Time programming mode.

 

Filter Cycle Start Time 

To adjust the filter cycle start time, push the Up or Down Pads and Light Pads as done in the Clock Set 
programming mode to choose a time. Once the desired time is displayed, push the Program Pad to accept the 
selection and move into the Filter Cycle Duration programming mode.

  

 

 

      Note 

You will be prompted later to set the filter cycle duration and the number of filter cycles. Be sure 
to keep this in mind when programming your filter cycle start time. During the filter cycle, JET 1 
will activate at high speed for the duration of the filter cycle. 

 

Filter Cycle Duration 

To adjust the filter cycle duration, push the Up or Down Pads to cycle through the choices of 60, 90, 120, 150 or 
180 minutes (the default is 60). Once the desired time is displayed, push the Program Pad to accept the selection 
and move into the Number of Filter Cycles programming mode.

 

 

 

  Caution 

Long and/or numerous filter cycles could cause overheating of the hot tub - especially in hot 
climates. 
 

Number of Filter Cycles 

To adjust the number of filter cycles per day, push the Up or Down Pad to cycle through the number of filter 
cycles - 1, 2, 3 or 4 (the default is 2). Once the desired number of cycles is displayed, push the Program Pad to 
accept the selection and move into the Temperature Unit Selection programming mode.

 

 

10

Содержание 2002 Arena

Страница 1: ...i...

Страница 2: ...2002 Dimension One Spas Export Owner s Manual ii...

Страница 3: ...HP CALIENTE AND TRIAD 7 Top Side Control 7 Digital Display Messages 9 OH Overheat Protection 9 Flashing LED on the Control Panel 9 Flashing Temperature on the Display 9 Summer Mode 9 Standby Mode 9 Us...

Страница 4: ...d the Triad II 18 Control Panel Description 18 Massage Zone Description 20 Operating the Dynamic Massage Sequencer 21 Initial Startup 21 ROUTINE EQUIPMENT MAINTENANCE 24 DRAINING YOUR EQUIPMENT 24 FIL...

Страница 5: ...f metal surfaces if each metal surface is permanently connected by a minimum No 8 AWG 8 4 mm2 solid copper conductor attached to the wire connector on the grounding lug inside the equipment compartmen...

Страница 6: ...re not covered under warranty Hyperthermia Prolonged immersion in hot water may induce hyperthermia A description of the causes symptoms and effects of hyperthermia are as follows Hyperthermia occurs...

Страница 7: ...maintenance of spa water is necessary to maintain safe water and prevent possible damage to spa components Caution Use the spa straps and clip tie downs to secure the cover when not in use This will...

Страница 8: ...with a Warning Sign and an Important Notice label This label outlines safety precautions This sign should be permanently placed in a location that is visible to the spa user Replacement signs can be o...

Страница 9: ...tile adds a distinctive touch Polyethylene floor completely seals the hot tub eliminating moisture or insect intrusion Built in automatic freeze protection Automatic high low speed filtration cycles...

Страница 10: ...be used in conjunction with your Ultra Pure or CrystalZone Water Management Systems The advantage of Vision over conventional halogens bromine and chlorine is that it will as a result of lower chemic...

Страница 11: ...is assured through design concepts and materials that meet or exceed CE rating Digital Control Figure 3 lets you relax and enjoy everything your hot tub has to offer Note Gain a thorough knowledge of...

Страница 12: ...al hot tub water temperature will again be indicated The hot tub will heat to the pre set temperature automatically 5 5 PROGRAM Pad The PROGRAM pad is used for several different functions including Cl...

Страница 13: ...34 F 16 6 C or 134 F 56 6 C DO NOT ENTER THE WATER The system has detected a problem Contact your local Authorized Dimension One Spas Dealer or authorized service center Summer Mode The SUMMER MODE f...

Страница 14: ...o a flashing AM or PM indicator Adjust the indicator with the Up and Down Pads When the desired indicator is displayed push the Program Pad to accept the selection and enter the Filter Cycle Start Tim...

Страница 15: ...rora XLT Caliente HP Californian Chairman Chairman II Diplomat Nautilus and Triad II Advanced microprocessor technology has been utilized to produce the Scrolling Message Center The most technological...

Страница 16: ...GHT Pad 1 Push LIGHT pad once to activate the brightest setting A second push will activate medium setting and a third push will activate the dimmest setting A message indicating current light intensi...

Страница 17: ...enheit Pressing the logo for 5 seconds will place the spa in the Standby mode and allow the spa to be cleaned without turning off the power 8 8 Heat Status Light This Light is illuminated whenever the...

Страница 18: ...lay we recommend that you have your hot tub inspected by your dealer as a preventative maintenance measure To reset this message push and hold the Dimension One Spas ICON logo pad located at the right...

Страница 19: ...MODE feature temporarily disables the circulation pump Cool Off cycle During hot weather the spa can experience Heat Creep Heat creep is caused when the spa during normal maintenance operations canno...

Страница 20: ...xit the time setting mode You will then be prompted to set the filter start time Filter Cycle Start Time After setting the time of day the top line of the Digital Display will read SET FILTER CYCLE TI...

Страница 21: ...inside and outside the hot tub To invert the text simply push the ENTER pad three times To return the text to its original position repeat this process push the ENTER pad three times Control Panel Loc...

Страница 22: ...read RESET PROGRAMMING The bottom line of the Digital Display will read IF SO PUSH ICON 4 Push the Dimension One ICON pad to reset the entire control system to factory defaults or do not touch a pad...

Страница 23: ...particular moment during the sequence and wants to keep it for an extended period of time the user may press the Begin Pause pad and the system will remain in the specific configuration until the pad...

Страница 24: ...ntrollable and interchangeable with directional jets These jets can be adjusted to change the area of coverage and the speed of the rotational pattern Zone 3 This zone is designed to massage the middl...

Страница 25: ...ndicated by an illuminated SEQUENCE Indicator Light 1 through 6 Note If the time between sequence changes is too fast or too slow you can push the SPEED pad to increase or decrease the time between se...

Страница 26: ...screw the cap onto the end of the hose bib 6 Check the pump unions Figures 10 and 11 to be sure that they are tight to prevent the possibility of leakage in the equipment compartment 1 Typical Locatio...

Страница 27: ...properly Note Ozone bubbles will continue to release from the skimmer recess Ultra Pure bleeder valve as long as the valve remains open Once the pumps are primed be sure that the bleeder is closed tig...

Страница 28: ...s Then pulls the basket assembly straight up to remove Next remove the E Z Lock Filter cartridge by twisting the cartridge 1 4 turn counterclockwise to its stop Be careful not to overturn the filter T...

Страница 29: ...oughly rinse the shell After cleaning you will want to restore your hot tub shell s original luster by using Dimension One Spas Poli Gloss Caution Do not use 409 type cleaners or other caustic solutio...

Страница 30: ...he system has proper electrical power and water level Therefore a fully operational system is your number one defense against freeze damage If you find it completely necessary to drain your water duri...

Страница 31: ...h bleeder valves from the top of the filter canister area Place hose of a high pressure air blower into the rear most bleeder fitting first Confirm that water mist is blowing from one or both of the c...

Страница 32: ...t the cover from warping or breaking You can even tarp the system at this point for maximum protection Spring Time Startup In the spring or when your ready to start the system back up follow these ins...

Страница 33: ...irty or chemically unbalanced water and cleaning of the hot tub filter are also the responsibility of the hot tub owner 5 Hot tub shell or equipment damage caused by improper water maintenance Serious...

Страница 34: ...high speed Lower Control System The electronic control system that governs all of the electrically operated components of your spa utilizes an advanced microprocessor and solid state electronic devic...

Страница 35: ...erature sensor is used to control the spa heater and the temperature is displayed on the spa side control panel Top Side Control Panel Used to control temperature pumps for jets spa light system clock...

Страница 36: ...ptom Problem Corrective Action Will not turn on in any mode No power Check circuit breaker and or GFCI Turns on by itself Normal automatic daily power filtration or anti freeze cycle No action require...

Страница 37: ...ve turned 2 Turn the Diverter Valve clockwise or counter clockwise 3 Dirty Filter 3 Clean Filter 4 Air lock 4 Loosen pump union to allow air to bleed No Jet Action or action is poor 5 Gate valve close...

Страница 38: ...2002 Dimension One Spas Export Owner s Manual 34...

Страница 39: ...2002 Dimension One Spas Export Owner s Manual 35...

Страница 40: ...2002 Dimension One Spas Export Owner s Manual 36...