Aquatic Fitness System
Troubleshooting Guide
28
Water System
Symptom
Problem
Corrective Action
Pulsating jets
Water level too low
Fill with water to 1” to 2” above bottom of
the tile line
1.
HydroTherapy Jets closed
1. Open
Jets
2. Diverter
Valve
turned
2. Turn the Diverter Valve clockwise or
counter clockwise
3. Dirty
Filter
3. Clean
Filter
4. Air
lock
4. Loosen
pump union to allow air to
escape
No Jet Action, or action is poor
5.
Gate valve closed
5.
Open gate valve
3 Flashing Lights
Symptom
Problem
Corrective Action
If the temperature fails to drop, or the
heater or other outputs fail to stop as
indicated, call the dealer.
High Temperature Protection:
If the water temperature exceeds 112
°
F at
the
Temperature Sensor
, the heater and all
other outputs will shut off.
If the water temperature exceeds 119
°
F at
the
Hi-Limit Sensor
, only the heater will be
shut off. All other outputs will continue to
operate.
After the water has cooled down, power to
the Aquatic Fitness System must be cycled
on, then off, to reset the system.
If the temperature does not
seem to be elevated, the error
indication may have been
caused by poor water flow or
electrical line interference
(thunder storms, voltage
surges, etc.) Simply reset and
monitor the system.
No action necessary, unless the water
temperature continues to drop and the
systems fails to activate. If this happens, you
should manually activate the heater and
pumps, if freezing could be a problem, then
call the dealer for service.
Smart Winter Mode:
If the system detects conditions below
59
°
F, the system will automatically activate
the Smart Winter Mode for a period of
24
hours
. In this mode, if a pump has not
been powered up in the last two hours, the
system will turn it on for one minute to
prevent freezing. The
Filter Mode Light
indicator will flash while the pump is
running in this mode.
If the spa water temperature drops below
49
°
F, the pump and heater will be turned
on for a period of 2 minutes, or until the
water reaches 50
°
F. All functions (except
the alarms) will be disabled while the freeze
protection is active.
If you notice your pumps
coming on every 2 hours, this
is most likely the cause. This
will continue for a 24-hour
period. This is normal and is
the Systems protection against
freezing.
Temperature Sensors:
If 33
°
F appears constantly on the display, or
if the temperature displayed greatly differs
from the actual temperature of the water,
your temperature sensor may be in need of
service.
Call the dealer for service.
Содержание 2002 Aquatic Fitness System
Страница 1: ...Aquatic Fitness System 2002 Owner s Manual...
Страница 2: ...Aquatic Fitness System ii...
Страница 26: ...Aquatic Fitness System 2002 Owner s Manual 22...
Страница 30: ...Aquatic Fitness System Glossary of Terms 26...
Страница 34: ...Aquatic Fitness System Troubleshooting Guide 30...
Страница 35: ......
Страница 36: ...Part No 01510 517 Rev B 2002 Dimension One Spas Inc...