28
C8 Value
Meter Attribute
0
Meter uses LCD3 new version of communication protocol, compatible with
LCD1 and LCD3
1
Meter uses LCD1 and LCD2 old version communication protocol, it is not
compatible with LCD3
2
As data source for copying parameters, the meter transfers the new LCD3
parameter to other meters
The C12 parameter setting will display on the meter after C11 settings. The KT-LCD3 will
display as follows:
C12 Controller Minimal Voltage Setting
C12 Value
Minimum Voltage (V)
24V Controller
36V Controller
48V Controller
0
Default Value-2V
Default Value-2V
Default Value-2V
1
Default Value-1.5V
Default Value-1.5V
Default Value-1.5V
2
Default Value-1V
Default Value-1V
Default Value-1V
3
Default Value-0.5V
Default Value-0.5V
Default Value-0.5V
4
Default Value=20V
Default Value=30V
Default Value=40V
5
Default Value+0.5V
Default Value+0.5V
Default Value+0.5V
6
Default Value+1V
Default Value+1V
Default Value+1V
7
Default Value+1.5V
Default Value+1.5V
Default Value+1.5V
C12 Display
C12 parameters are settings for the controller's minimum operating voltage (voltage
shortage value). Refer to the following table to calculate the minimum voltage.
C13 Value
ABS Braking Strength
Energy Recovery Efficiency
0
None
None
1
Class 1 Braking Strength
Best energy recovery
2
Class 2 Braking Strength
General energy recovery
3
Class 3 Braking Strength
Weaker energy recovery
4
Class 4 Braking Strength
Poor energy recovery
5
Class 5 Braking Strength
Bad energy recovery