-46-
recording data on it for normal operation.
-
Max File Size
is the menu for limitting the size of AVI file. If it is set a small
size, file is created in small size and but numbers of file will be increased. If
the recording time is over 10 minutes, new file will be created even though file
size is smaller than size of file set in
Max File Size
.
Event Type
-
Three recording modes are supported in STREAMERH264:
Full-time
,
Event
,
Disconnect
. In case of Event recording, event types can be selected among
several events. Selected event type is used for configuring the schedule table.
Up to 4 event types can be configured and each event type can be a
combination of sensor, video loss and motion event.
-
Pre / Post Event Time
specifies the duration of recording before and after an
event happens and they are applied to 4 event types commonly.
Schedule Table
-
Actual recording mode is determined by
Schedule Table
, where recording
mode configured by day(of a week) and time.
-
Each of recording mode configures the recording operation as follows:
•
Record off
: No recording
•
Continuous
: Records continuously
•
Disconnect
: Data is recorded when the system loses the connection to its
client(Decoder, CMS/NVR) etc. When one of its multiple clients system is
disconnected, this doesn’t happen.
•
Event Type
: Records when an event configured in
Event Type
setting
happens.