![DIGIVISION STREAMERH264 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/digivision/streamerh264/streamerh264_user-manual_2502213036.webp)
www.digivision.it StreamerH264 User Manual
Distributore per l’Italia :
http://www.digivision.it
_
DIGIVISION srl - Viale Piave 3 - 20129 MILANO Italy
te+39 02 7600 7932 - fax ++39 02 7601 6305
Ufficio vendite e-mail : [email protected]
-35-
There are two serial ports, (COM1 and COM2) in STREAMERH264. While
COM1 port is fixed to RS-232C, COM2 port can be set to RS-422 or RS-485
protocol.
The serial ports can be configured as follows.
Mode
Selection
Bitrate
2400, 4800, 9600, 19200, 38400, 57600,
115200 bps
Data Bits
5, 6, 7, 8 bits
Parity
NONE, EVEN, ODD bit
Stop Bit
1, 2 bit
Each of the serial ports configurations must be same as connecting device.
PTZ Configuration
PTZ Type
Select the type of PTZ camera or receiver.
PTZ ID
Since it is possible to control multiple PTZ cameras or receivers over
single control line, each camera or receiver will be assigned with unique
ID. Enter PTZ ID of a camera or receiver for control. The ID value range
can be between 0 and 255.
PTZ Port
Select the serial port used for PTZ camera control.
Sensor Type
There are two sensor input ports on STREAMERH264. Each of the sensor
ports can be configured to the following.