background image

 1

 

 
 

2SFP Port 10/100/1000Mbps 

Web Smart Ethernet Switch 

 

 

DN-80201

 

 

DN-80211-1 

 

DN-80221-1 

 

Manual 

DN-80201 

 DN-80211-1 

 DN-80221-1

 

 

Содержание DN-80201

Страница 1: ...1 2SFP Port 10 100 1000Mbps Web Smart Ethernet Switch DN 80201 DN 80211 1 DN 80221 1 Manual DN 80201 DN 80211 1 DN 80221 1 ...

Страница 2: ...ort 13 2 1 2 Rack mountable Installation in 19 inch Cabinet 8 port 13 2 1 3 Power on the Switch 8 port 14 2 1 4 Desktop Installation 16 port 14 2 1 5 Rack mountable Installation in 19 inch Cabinet 16 port 15 2 1 6 Power on the Switch 16 port 16 2 1 7 Desktop Installation 24 port 16 2 1 8 Rack mountable Installation in 19 inch Cabinet 24 port 17 2 1 9 Power on the Switch 24 port 18 2 2 Connect Comp...

Страница 3: ...Mac Address Table 48 4 4 1 Static Mac Setting 48 4 4 2 MAC Filtering 49 4 4 3 Dynamic Address Setting 49 4 4 4 Dynamic Learned 50 4 4 5 RMA MAC Address 50 4 5 Security 50 4 5 1 Storm Control 50 4 5 2 802 1X 51 4 5 3 DHCP Snooping 53 4 5 4 Port Security 57 4 5 5 AAA 58 4 5 6 Tacacs Server 61 4 5 7 Radius server 61 4 5 8 Access 62 4 6 ACL 65 4 6 1 MAC Based ACL 65 4 6 2 MAC Based ACE 65 4 6 3 IPv4 B...

Страница 4: ...9 1 System Status 84 4 9 2 Ping Test 84 4 9 3 Logging Setting 85 4 9 4 Factory Default 86 4 9 5 Reboot Switch 86 4 10 Maintenance 87 4 10 1 Backup Manager 87 4 10 2 Upgrade Manager 88 4 10 3 Configuration Manager 88 4 10 4 Account Manager 89 4 10 5 Enable Password 90 ...

Страница 5: ...figured by web based interface Including administrator port management VLAN setting port statistics trunking QoS setting security filter configuration backup recovery log out and so on 1 2 Features 8 port Complies with IEEE802 3 IEEE 802 3u IEEE 802 3ab standards 8 x 10 100 1000Mbps Auto Negotiation RJ45 ports supporting Auto MDI MDIX Support Console port management Supports IEEE802 3x flow contro...

Страница 6: ...icators for monitoring power link activity Web based Management Support Internal power adapter supply 1 2 2 Features 24 port Comply with IEEE802 3 IEEE802 3u IEEE802 3ab IEEE802 3x IEEE802 3z EEE802 3ad standards Supports IEEE802 3x flow control for Full duplex Mode and back pressure for Half duplex Mode Supports MAC address auto learning and auto aging Store and forward mode operates Support SNMP...

Страница 7: ...ponding 10 100 1000Mbps LED SFP ports SFP1 SFP2 Designed to install SFP module and connect to devices with a bandwidth of 1000Mbps Each has a corresponding 1000Mbps LED Console port Console Designed to connect with serial port of a computer or terminal for monitoring and configuring the Switch Reset button Reset Keep the device powered on and press down the button for about 5 seconds The system re...

Страница 8: ...nected to the port Off No device is connected to the port 1000Mbps Green Flashing Sending or receiving data SFP1 SFP2 Green On A device is connected to the port Off No device is connected to the port Flashing Sending or receiving data 1 3 2 Rear Panel 8 port The rear panel of the Switch contains AC power connector shown as below Figure 3 Rear Panel AC Power Connector Power is supplied through an e...

Страница 9: ...00 1000Mbps LED SFP ports SFP1 SFP2 Design to install the SFP module and connect to the device with a bandwidth of 1000Mbps Each has a corresponding 1000Mbps LED Console port Console Design to connect with the serial port of a computer or terminal for monitoring and configuring the Switch Reset button Reset Keep the device powered on and press down the button for about 5 seconds The system restore...

Страница 10: ...data SFP1 SFP2 Green On A device is connected to the port Off No device is connected to the port Flashing Sending or receiving data 1 3 5 Rear Panel 16 port The rear panel of the Switch contains AC power connector shown as below Figure 3 Rear Panel AC Power Connector Power is supplied through an external AC power adapter It supports AC 100 240V 50 60Hz Grounding Terminal The Switch already comes w...

Страница 11: ...00 1000Mbps LED SFP ports SFP1 SFP2 Design to install the SFP module and connect to the device with a bandwidth of 1000Mbps Each has a corresponding 1000Mbps LED Console port Console Design to connect with the serial port of a computer or terminal for monitoring and configuring the Switch Reset button Reset Keep the device powered on and press down the button for about 5 seconds The system restore...

Страница 12: ...vice is disconnected to the port Flashing Sending or receiving data 1 3 8 Rear Panel 24 port The rear panel of the Switch contains AC power connector and one marker shown as below Figure 3 Rear Panel AC Power Connector Power is supplied through an external AC power adapter It supports AC 100 240V 50 60Hz Grounding Terminal The Switch already comes with Lightning Protection Mechanism You can also g...

Страница 13: ...ntact your local agent immediately In addition make sure that you have the tools install switches and cables by your hands One Web Smart Ethernet Switch Four rubber feet two mounting ears and eights screws One AC power cord One User Manual 1 4 2 Package Contents 24 port Before installing the Switch make sure that the following the packing list listed OK If any part is lost and damaged please conta...

Страница 14: ... from and adequate ventilation around the Switch Make sure that the cabinet has enough back up for the weight of the Switch and its accessories 2 1 1 Desktop Installation 8 port Sometimes users are not equipped with the 19 inch standard cabinet So when installing the Switch on a desktop please attach these cushioning rubber feet provided on the bottom at each corner of the Switch in case of the ex...

Страница 15: ...ect the metal ground connector to the grounding source on the outlet AC Power Cord Connection Connect the AC power connector in the back panel of the Switch to external receptacle with the included power cord and check the power indicator is ON or not When it is ON it indicates the power connection is OK 2 1 4 Desktop Installation 16 port Sometimes users are not equipped with the 19 inch standard ...

Страница 16: ...ack which can be placed in a wiring closet with other equipment To install the Switch please follow these steps c Attach the mounting brackets on the Switch s side panels one on each side and secure them with the screws provided Figure 5 Bracket Installation d Use the screws provided with the equipment rack to mount the Switch on the rack and tighten it ...

Страница 17: ...ing source on the outlet AC Power Cord Connection Connect the AC power connector in the back panel of the Switch to external receptacle with the included power cord and check the power indicator is ON or not When it is ON it indicates the power connection is OK 2 1 7 Desktop Installation 24 port Sometimes users are not equipped with the 19 inch standard cabinet So when installing the Switch on a d...

Страница 18: ...can be mounted in an EIA standard sized 19 inch rack which can be placed in a wiring closet with other equipment To install the Switch please follow these steps e Attach the mounting brackets on the Switch s side panels one on each side and secure them with the screws provided Figure 5 Bracket Installation ...

Страница 19: ...g source on the outlet AC Power Cord Connection Connect the AC power connector in the back panel of the Switch to external receptacle with the included power cord and check the power indicator is ON or not When it is ON it indicates the power connection is OK 2 2 Connect Computer NIC to the Switch Please insert the NIC into the computer after installing network card driver please connect one end o...

Страница 20: ... Switch provides Web based management login you can configure your computer s IP address manually to log on to the Switch The default settings of the Switch are shown below Parameter Default Value Default IP address 192 168 2 1 Default user name admin Default password admin You can log on to the configuration window of the Switch through following steps 1 Connect the Switch with the computer NIC i...

Страница 21: ... Login Window 5 Enter the Username and Password The factory default Username is admin and Password is admin and then click LOGIN to log in to the Switch configuration window as below Figure 8 Configuration Window ...

Страница 22: ...he Switch provides Web based management login you can configure your computer s IP address manually to log on to the Switch The default settings of the Switch are shown below Parameter Default Value Default IP address 192 168 2 1 Default user name admin Default password admin You can log on to the configuration window of the Switch through following steps 6 Connect the Switch with the computer NIC...

Страница 23: ... Login Window 10 Enter the Username and Password The factory default Username is admin and Password is admin and then click LOGIN to log in to the Switch configuration window as below Figure 9 Configuration Window ...

Страница 24: ... Switch provides Web based management login you can configure your computer s IP address manually to log on to the Switch The default settings of the Switch are shown below Parameter Default Value Default IP address 192 168 2 1 Default user name admin Default password admin You can log on to the configuration window of the Switch through following steps 11 Connect the Switch with the computer NIC ...

Страница 25: ... Login Window 15 Enter the Username and Password The factory default Username is admin and Password is admin and then click LOGIN to log in to the Switch configuration window as below Figure 9 Configuration Window ...

Страница 26: ... squares indicate the port link is up while black squares indicate the port link is down Below the switch panel you can find a common toolbar to provide useful functions for users The rest of the screen area displays the configuration settings 4 1 Status Use the Status pages to view system information and status 4 1 1 System Information To display System Information web page click Status System In...

Страница 27: ...ging Message web page click Status Logging Message Target Select the log message source to show on the table RAM Logs store in the RAM disk DHCP Logs store in the FLASH Severity Select severity to filter log messages Category Select category to filter log messages 4 1 3 Port The Port configuration page displays port summary and status information 4 1 3 1 Port Counters To display Port Counters web ...

Страница 28: ...through each port 4 1 3 2 Port Error Disabled To display Port Error Disabled web page click Status Port Port Error Disabled This page allow user to browse ports which disabled by some protocols such as BPDU Guard Loop back and UDLD The Recovery button will enable those error disabled ports 4 1 3 3 Bandwidth Utilization To display Bandwidth Utilization web page click Status Port Bandwidth Utilizati...

Страница 29: ...nctional ports and alternative ports LAG LAG ID Name LAG Name Type The type of the LAG group a static LAG or an LACP LAG 4 1 5 LLDP Statistics To display LLDP Statistics status click Status LLDP Statistics The Link Layer Discovery Protocol LLDP Statistics page displays summary and per port information for LLDP frames transmitted and received on the switch ...

Страница 30: ...mber of times the complete set of information advertised by MSAP could not be entered into tables associated with the remote systems because of insufficient resources Age Outs The number of times the complete set of information advertised by MSAP has been deleted from tables associated with the remote systems because the information timeliness interval has expired 4 1 6 IGMP Snooping Statistics To...

Страница 31: ...IP information from a DHCP server on the network IP Address If static mode is enabled enter IP address in this field Subnet Mask If static mode is enabled enter subnet mask in this field Gateway If static mode is enabled enter gateway address in this field 4 2 2 Time Settings 4 2 2 1 System Time To display System Time web page click Network Time Settings System Time This page allow user to enable ...

Страница 32: ...NTP server Server Port The Port Number of SNTP NTP server 4 3 Switching Use the Switching pages to configure settings for the switch ports trunk layer 2 protocols and other switch features 4 3 1 Port Setting To display Port Setting web page click Switching Port Setting This page allow user to configure the port status port speed and duplex mode ...

Страница 33: ...ability only Auto 10M 100M Auto speed with 10M 100M abilities 10M Force speed with 10M ability 100M Force speed with 100M ability 1000M Force speed with 1000M ability Duplex Port duplex capabilities Auto Auto duplex with all capabilities Full Auto speed with full duplex ability only Half Auto speed with half duplex ability only Flow Control Port flow control Enable Enable flow control ability Disa...

Страница 34: ...ort commonly used in port mirroring 4 3 4 Link Aggregation Link aggregation combine multiple Ethernet ports together to form a logical port it supports static allocation or LACP 4 3 4 1 LAG Setting To display LAG Setting web page click Switching Link Aggregation LAG Setting This page allow user to configure Ports aggregation rules that is depended on MAC Address or IP MAC Address ...

Страница 35: ...regation LAG Management This page is used to create new LAG ports aggregation type and select member ports 4 3 4 3 LAG Port Setting To display LAG Port setting web page click Switching Link Aggregation LAG Port Setting This page is used to set LAG status speed and flow control function ...

Страница 36: ...e is used to configure the system Priority of LACP System Priority Configure the system priority of LACP This decides the system priority field in LACP PDU 4 3 4 5 LACP Port Setting To display LACP Port Setting web page click Switching Link Aggregation LACP Port Setting This page is used to set LACP member ports ...

Страница 37: ...VLAN settings VLAN LIST VLAN LIST for the new VLAN VLAN Action Add or delete VLAN VLAN Name Prefix VLAN Name Prefix for the new VLAN 4 3 5 2 Interface Settings To display VLAN Interface Settings web page click Switching VLAN Management Interface Settings This page allows the user to set the port type of VLAN the port VLAN ID and whether the port should have a tag ...

Страница 38: ...d frame Untag Only Only accept untagged frame Ingress Filtering Choose filter port open and close Uplink Select port Uplink open or close 4 3 5 3 Port to VLAN To display Port to VLAN web page click Switching VLAN Management Port to VLAN Select the port s different behaviors when it works under the VLAN 4 3 5 4 Port VLAN Membership To display Port VLAN Membership web page click Switching VLAN Manag...

Страница 39: ...anumeric string of up to 16 characters Frame Type This function maps packets to protocol defined VLAN by examining the type octet within the packet header to discover the type of protocol associated with it Ethernet_II packet type is Ethernet version 2 IEEE802 3_LLC_Other packet type is 802 3 packet with LLC other header RFC_1042 packet type is RFC 1042 packet Protocol Value 0x0600 0xFFFE Enter th...

Страница 40: ...lick the corresponding radio button to select a previously configured VLAN ID or VLAN Name 4 3 6 Multicast 4 3 6 1 Properties To display Properties web page click Switching Multicast Properties This page is used to set message behavior and iPv4 message forwarding rules 4 3 6 2 IGMP Snooping Use the Switching pages to configure settings for the switch network interface 1 IGMP Setting To display IGM...

Страница 41: ... IGMP Snooping Querier Setting web page click Switching Multicast IGMP Snooping IGMP Snooping Querier Setting VLAN ID Select the VLANs to configure Querier State Set enabling status of IGMP Querier Election on the VLANs Enable Enable IGMP Querier Election Disable Disable IGMP Querier Election Version Select the Querier Version IGMPv2 or IGMPv3 3 IGMP Static Group To display IGMP Static Setting web...

Страница 42: ...click Switching Multicast IGMP Snooping IGMP Group Table This page is used to display IGMP Group Table statistics information 5 IGMP Router Port Setting To display IGMP Router Port Setting web page click Switching Multicast IGMP Snooping IGMP Router Port Setting This page is used to configure specified ports as static route ports ...

Страница 43: ...e web page click Switching Multicast IGMP Snooping IGMP Router Table This page is used to display IGMP Router Table statistics information 7 IGMP Forward All To display IGMP Forward All web page click Switching Multicast IGMP Snooping IGMP Forward All ...

Страница 44: ...cast Throttling Setting This page is used to limit the port can join one of the biggest Multicast instance 4 3 6 4 Multicast Filter This page allow user to create filter instance 1 Multicast Profile Setting To display Multicast Profile Setting web page click Switching Multicast Multicast Filter Multicast Profile Setting ...

Страница 45: ...e click Switching Multicast Multicast Filter IGMP Filter Setting This page is used to filter the port to bind to that instance 4 3 7 Jumbo Frame To display Jumbo Frame web page click Switching Jumbo Frame Jumbo Frame Jumbo frame size The valid range is 0 bytes 9216 bytes ...

Страница 46: ...e enable disable on the Switch BPDU Forward Choose BPDU packets is a flood or filtering Path Cost Method Choose the path overhead is short or long Force Version Select the operating mode of STP STP Compatible 802 1D STP operation RSTP Operation 802 1w operation MSTP Operation 802 1s operation Configuration Revision Set the revision of the configuration identification Range 0 65535 4 3 8 2 STP Port...

Страница 47: ...ction To avoid transmitting BPDU from the specified ports BPDU Guard Set the BPDU Guard configuration No Disable BPDU guard function Yes Enable BPDU filter function To drop directly the received BPDU from the specified ports P2P MAC Set the Point to Point port configuration No Force to false state Yes Force to true state Migrate Force to try to use the new MST RST BPDUs and hence to test the hypot...

Страница 48: ...it BPDIU transmission rate Hello Time Set the interval between periodic transmissions of BPDU by designated ports 4 3 8 4 CIST Port Setting To display CIST Port Setting web page click Switching STP CIST Port Setting Port Select Select the port list to specify which ports should apply this setting Priority Set the port priority to the selected ports in the specified CIST instance Internal Path Cost...

Страница 49: ...ST Port Setting MST ID Set the MSTI ID to specify MST instance Port Select Select the port list to specify which ports should apply this setting Priority Set the port priority to the selected ports in the specified MST instance Internal Path Cost Set the internal path cost to the selected ports in the specified MST instance 0 means Auto 4 3 8 7 STP Statistics To display STP Statistics web page cli...

Страница 50: ... type is unicast enter unicast MAC address in this field if type is multicast enter multicast MAC address in this field Port If type is unicast select the port number of the MAC entry if type is multicast select the port list of the MAC entry VLAN The VLAN ID number of the VLAN on which the above MAC address resides 4 4 2 MAC Filtering To display MAC Filtering web page click Mac Address Table MAC ...

Страница 51: ...arned web page click Mac Address Table Dynamic Learned Port Select the port number to show or clear dynamic MAC entries If not select any port VLAN and MAC address the whole dynamic MAC table will be displayed or cleared VLAN Select the VLAN to show or clear dynamic MAC entries If not select any port VLAN and MAC address the whole dynamic MAC table will be displayed or cleared MAC Address Select t...

Страница 52: ...Storm Control Global Setting Unit Choose storm control unit is pps or bps Preamble IFG Select the rate calculates w o preamble IFG 20 bytes Excluded exclude preamble IFG 20 bytes when count ingress storm control rate Included include preamble IFG 20 bytes when count ingress storm control rate 4 3 5 2 Port Setting To display Port Setting web page click Security Storm Control Port Setting ...

Страница 53: ...ver access control and authentication protocol It can restrict unauthorized users or devices to connect the access port via LAN WLAN Before getting permission from the switch 802 1x will check the users or devices that connect with the switch ports EAPoL data are transmitted between device and switch when the device is allowed to access all data can be transmitted through Ethernet ports 4 5 2 1 80...

Страница 54: ...rt Setting Port Select the ports to configure their authentication mode Mode The authentication mode Force Unauthorized Force this port to be unconditional unauthorized Force Authorized Force this port to be unconditional authorized Authentication 802 1X authentication No Authentication 802 1X disabled ...

Страница 55: ...tting web page click Security 802 1X Guest VLAN Setting 4 3 5 1 Authenticated Hosts To display Authenticated Hosts web page click Security 802 1X Authenticated Hosts 4 5 3 DHCP Snooping When the switch opens DHCP Snooping it will snoop DHCP message and receive DHCP Request and abstract and record the IP address and MAC address from DHCP ACK message Besides DHCP Snooping admits one physical port se...

Страница 56: ...l Setting To display Global Setting web page click Security DHCP Snooping Global Setting This page is used to open DHCP Snooping function DHCP Snooping enable or disable DHCP Snooping function 4 5 3 2 VLAN Setting To display VLAN Setting web page click Security DHCP Snooping VLAN Setting Specific VLAN starts DHCP Snooping 4 5 3 3 Port Setting To display Port Setting web page click Security DHCP Sn...

Страница 57: ...splay Statistics web page click Security DHCP Snooping Statistics This page shows statistics of each port s DHCP Snooping state information 4 5 3 5 Rate Limit To display Rate Limit web page click Security DHCP Snooping Rate Limit ...

Страница 58: ...2 Global Setting This page is used to configure DHCP Snooping support Option82 strategy 4 5 3 7 Option82 Port Setting To display Option82 Port Setting web page click Security DHCP Snooping Option82 Port Setting To the specified port configuration of receiving containing Option 82 options request packet port handling strategy ...

Страница 59: ...ing web page click Security DHCP Snooping Option82 Circuit ID Setting This page allow user to edit circuit ID content in the option82 4 5 4 Port Security To display Port Security web page click Security Port Security Ports Security can set port isolation and specific behavior ...

Страница 60: ...y which can be learned by a port 4 5 5 AAA 4 5 5 1 Login List To display Login List web page click Security AAA Login List This page allow user to add edit or delete login authentication list settings The default list cannot be deleted The line combined to this list will authenticate login user by methods in this list If the first method is failed it will try to use the next priority method to aut...

Страница 61: ...thenticate Tacacs Use remote TACACS server to authenticate Radius Use remote Radius server to authenticate Not supported now it will be supported in the future Enable Use local enable password to authenticate Method 4 Select forth priority of login authentication method Local Use local accounts database to authenticate Tacacs Use remote TACACS server to authenticate Radius Use remote Radius server...

Страница 62: ...le authentication method Enable Use local enable password to authenticate Tacacs Use remote TACACS server to authenticate Radius Use remote Radius server to authenticate Not supported now it will be supported in the future 4 5 5 3 Accounting List To display Accounting List web page click Security AAA Accounting List This page allow user to add edit or delete accounting list settings The default li...

Страница 63: ... remote TACACS server to accounting Radius Use remote Radius server to accounting Not supported now it will be supported in the future 4 5 5 4 Accounting Update To display Accounting Update web page click Security AAA Accounting Update 4 5 6 Tacacs Server To display Tacacs server web page click Security AAA Tacacs server This page allow user to add edit or delete TACACS server settings 4 5 7 Radiu...

Страница 64: ...rized and accounted by AAA lists we combined here Login Authentication List Select one of the login authentication lists we configured in Login List page Enable Authentication List Select one of the enable authentication lists we configured in Enable List page EXEC Authorization List Select one of the EXEC authorization lists we configured in EXEC List page Commands Authorization List Select one o...

Страница 65: ...thentication lists we configured in Login List page Enable Authentication List Select one of the enable authentication lists we configured in Enable List page EXEC Authorization List Select one of the EXEC authorization lists we configured in EXEC List page Commands Authorization List Select one of the commands authorization lists we configured in Commands List page EXEC Accounting List Select one...

Страница 66: ...To display HTTPS web page click Security Access HTTPS This page allow user to combine all kinds of AAA lists to HTTPS line The user accesses switch WEBUI from HTTPS will be authenticated by AAA lists we combined here HTTPS Server Set HTTPS Server disable or enable Login Authentication List Select one of the login authentication lists we configured in Login List page Session Timeout Set session tim...

Страница 67: ...me in this field 4 6 2 MAC Based ACE To display MAC Based ACE web page click ACL MAC Based ACE This page allow user to set Based on MAC address expanding ACL list matching corresponding MAC and setting the ports as drop or forward 4 6 3 IPv4 Based ACL To display IPv4 Based ACL web page click ACL IPv4 Based ACL This page allow user to set name for IPv4 Based ACL ...

Страница 68: ...page allow user to set based on IPv4 expanding ACL Peer Guardian and matching corresponding IP and setting the port as drop or forward 4 6 5 ACL Binding To display ACL Binding web page click ACL ACL Binding This page allow user to bounding with accordingly ACL rules port bounding ACL rules ...

Страница 69: ... properties This page allow user to set QoS mode basic or advanced 4 7 1 2 Port Settings To display Port Settings web page click QoS General Port Settings This page is used to give the QoS instance port configuration 4 7 1 3 Queue Settings To display Queue Setting web page click QoS General Queue Settings This page allow user to set the QoS instance queue scheduling model ...

Страница 70: ...apping web page click QoS General COS Mapping The page allow user to set QoS instance of COS Mapping 4 7 1 5 DSCP Mapping To display DSCP Mapping web page click QoS General DSCP Mapping The page allow user to set QoS instance of DSCP Mapping ...

Страница 71: ... General IP Precedence The page allow user to set QoS instance of IP Precedence Mapping 4 7 2 QoS Basic Mode 4 7 2 1 Global Settings To display Global Settings web page click QoS QoS Basic Mode Global Settings This page allow user to set QoS for trust mode on basic mode global settings ...

Страница 72: ...gs This page allow user to set QoS port setting enabled or disabled 4 7 3 QoS Advanced Mode 4 7 3 1 Global Settings To display Global Settings web page click QoS QoS Advanced Mode Global Settings This page allow user to set the default QoS mode state under advanced mode global settings trust mode ...

Страница 73: ...lass Mapping This page allow user to create a QoS class which is used to link the ACL 4 7 3 3 Aggregate Policer To display Aggregate Policer web page click QoS QoS Advanced Mode Aggregate Policer 4 7 3 4 Policy Table To display Policy Table web page click QoS QoS Advanced Mode Policy Table ...

Страница 74: ... 3 5 Policy Class Maps To display Policy Class Maps web page click QoS QoS Advanced Mode Policy Class Maps 4 7 3 6 Policy Binding To display Policy Binding web page click QoS QoS Advanced Mode Policy Binding ...

Страница 75: ...t ingress port monitor 4 7 4 2 Ingress VLAN Settings To display Ingress VLAN Settings web page click QoS Rate Limit Ingress VLAN Settings This page is used to set the bandwidth of the VLAN entry control 4 7 4 3 Egress Port Settings To display Egress Port Settings web page click QoS Rate Limit Egress Port Settings This page is used to set the egress port monitor ...

Страница 76: ...ettings The page is used to set the egress lined up bandwidth monitor 4 8 Management 4 8 1 LLDP LLDP is a one way protocol there are no request response sequences Information is advertised by stations implementing the transmit function and is received and processed by stations implementing the receive function ...

Страница 77: ...al at which frames are transmitted The default is 30 seconds and the valid range is 5 32768 seconds Hold time Multiplier Select the multiplier on the transmit interval to assign to TTL Range 2 10 default 4 Reinitialization Delay Select the delay before a re initialization range 1 10 seconds default 2 4 8 1 2 LLDP Port Settings To display LLDP Port Settings web page click Management LLDP LLDP Port ...

Страница 78: ...ion state Port Select Select specific ports Optional TLV Select Select Optional TLVs 4 8 1 3 LLDP Local Device To display LLDP Local Device web page click Management LLDP LLDP Local Device Use the LLDP Local Device page to view information about devices on the network for which the switch has received LLDP information 4 8 1 4 LLDP Remote Device To display LLDP Remote Device web page click Manageme...

Страница 79: ... 1 5 LLDP Network Policy To display LLDP Network Policy web page click Management LLDP LLDP Network Policy 4 8 1 6 MED Port Setting To display MED Port Setting web page click Management LLDP MED Port Setting ...

Страница 80: ...ate Enabled Enable SNMP daemon Disabled Disable SNMP daemon 4 8 2 2 SNMP View To display SNMP View web page click Management SNMP SNMP View This page is used to configure SNMP view used in the SNMP message Management variables OID to describe the switch in the Management object MIB Management Information Base is a set of monitoring network equipment Management variables View is used to control var...

Страница 81: ...hin the group the user can set read only or write only 4 8 2 4 SNMP Community To display SNMP Community web page click Management SNMP SNMP Community SNMP v1 and SNMP v2c uses the group Name Community Name certification which is similar to the password If use SNMP v1 and SNMP v2c after configuring SNMP view the SNMP community can be directly configured ...

Страница 82: ...er This page is used to create SNMP user under the group and the group with the same level of security and access control permissions 4 8 2 6 SNMPv1 2 Notification Recipients To display SNMPv1 2 Notification Recipients web page click Management SNMP SNMPv1 2 Notification Recipients ...

Страница 83: ...otification Recipients To display SNMPv3 Notification Recipients web page click Management SNMP SNMPv3 Notification Recipients 4 8 2 8 SNMP Engine ID To display SNMP Engine ID web page click Management SNMP SNMP Engine ID ...

Страница 84: ...ck Management SNMP SNMP Remote Engine ID 4 8 3 RMON 4 8 3 1 RMON Statistics To display RMON Statistics web page click Management RMON RMON Statistics 4 8 3 2 RMON Event To display RMON Event web page click Management RMON RMON Event This page is used to configure RMON event group ...

Страница 85: ...og 4 8 3 4 RMON Alarm To display RMON Alarm web page click Management RMON RMON Alarm This page is used to configure RMON statistics group and alarm group 4 8 3 5 RMON History To display RMON History web page click Management RMON RMON History This page is used to configure the RMON history group ...

Страница 86: ...og 4 9 Diagnostics Use the Diagnostics pages to configure settings for the switch diagnostics feature or operating diagnostic utilities 4 9 1 System Status To display System Status Log web page click Diagnostics System Status 4 9 2 Ping Test To display Ping Test Log web page click Diagnostics Ping Test ...

Страница 87: ...est packet Size The size of ping packet Ping Results After ping finished results will show in this field 4 9 3 Logging Setting 4 9 3 1 Logging Service To display Logging Service web page click Diagnostics Logging Setting Logging Service 4 9 3 2 Local Logging To display Local Logging web page click Diagnostics Logging Setting Local Logging ...

Страница 88: ...page click Diagnostics Logging Setting Remote Logging Server Address The IP address of remote log server Server Port The Port number of remote log server Severity Select severity of log messages which will be sent 4 9 4 Factory Default To display Factory Default web page click Diagnostics Factory Default This page allow user to restore switch to factory default by pushing Restore button 4 9 5 Rebo...

Страница 89: ...lick Maintenance Backup Manager This page allow user to backup the firmware image or configuration file on the switch to remote TFTP server or host file system through HTTP protocol Backup Method Select backup method TFTP Use TFTP to backup HTTP Use HTTP to backup Server IP IP address of the TFTP server If the TFTP backup method is selected the IP address of the TFTP server must be assigned Backup...

Страница 90: ... IP address of the TFTP server If the TFTP upgrade method is selected the IP address of the TFTP server must be assigned File Name Firmware image or configuration file name on remote TFTP server If the TFTP upgrade method is selected the file name must be specified Browse file If the HTTP upgrade method is selected the browse file field allows you to select any file on host operating system Upgrad...

Страница 91: ... is not No Password the password must be specified Retype Password Retype password to make sure the password is exactly you typed before in Password field Privilege Type Select privilege level for new account Admin Allow to change switch settings User See switch settings only Not allow to change it If AAA feature is enabled we have one more privilege type to allow user adding privilege value for t...

Страница 92: ...level for this account here The valid privilege level is from 2 to 14 4 10 5 Enable Password To display Enable Password web page click Maintenance Enable Password This page allow user to modify the enable password In command line interface user can use enable command to change their privilege level to Admin After enable command is issued user need to type the enable password to change their privil...

Страница 93: ...eses Produkt entspricht der Prüfklasse A es kann im Wohnbereich Funkstörungen verursachen in diesem Fall kann vom Betreiber verlangt werden angemessene Maßnahmen durchzuführen und dafür aufzukommen Konformitätserklärung Das Gerät erfüllt die EMV Anforderungen nach EN 55022 Klasse A für ITE und EN 55024 Geräte mit externer oder eingebauter Spannungsversorgung erfüllen weiterhin die Anforderungen na...

Отзывы: