background image

 

 

db

 

ServerRack

 

V2

 

(Zero-U)  

Installation Manual 

Содержание dbServerRackV2 Zero-U

Страница 1: ...dbServerRackV2 Zero U Installation Manual ...

Страница 2: ...ting the Door Interface Box Step 4 8 Mounting the Door Interface Box Step 5 9 Mount the Tie Down Pads to the Door and Cabinet 10 Connect the CAT5 Cable to the Control Unit 12 Installing the Pawl on the Door Lock 14 Using the Tamper Switch Inputs 15 Using the Door Contact Inputs 17 Using the Alarm Output 19 Using the Wiegand Output 20 Using the Door 2 Output 21 Install the 2 nd BioLock Option I 21 ...

Страница 3: ... of your cabinet There are 2 simple measurements that need to be taken to determine which pawl you will need Please obtain the measurements as show in Figure 1 and Figure 2 and contact our electromechanical lock support team as show below Southco Global Corporate Headquarters Customer Service Technical Support Ctr Concordville PA USA Tel 610 459 4000 Email info southco com Figure 1 Figure 2 ...

Страница 4: ...rol Unit o The Control Unit can be attached using the Magnetic Strips for Steel Cabinets or VHB Strips for Aluminum Cabinets o Alternatively the Control Unit can be placed on a cabinet shelf It is preferable to mount the Control Unit near the top of the rack to ease the running of cables however this isn t absolutely necessary Figure 3 ...

Страница 5: ...ide of the cabinet door to mount Interface Box Ensure that the selected location will not affect the cabinet door from closing correctly Note that for glass paneled cabinet doors with very narrow frames the only suitable location may be on the glass IMPORTANT Ensure that the Interface Box is located close enough to the lock opening in the door so that the finger sensor on the ribbon cable can go t...

Страница 6: ...not prevent the cabinet door from closing Once you have ensured that the door will close properly and the finger sensor can attach to the lock apply more pressure to the high bond tape The more pressure applied the greater the bond Figure 5 Open slot for lock 25mm x 150mm typical IMPORTANT Ensure that the Interface Box is located close enough to the lock opening in the door so that the finger sens...

Страница 7: ...x Step 3 Push the finger sensor assembly through the door lock opening as shown in Figure 6 Attach the finger sensor assembly into the back of the door lock as show in Figure 7 Ensure that the angle of the finger sensor assembly and the angle of the door lock are as shown in Figure 7 Figure 6 Figure 7 ...

Страница 8: ...metrics Inc 2011 Page 8 of 24 Mounting the Door Interface Box Step 4 Situate the lock on the outside of the cabinet door so that the ribbon cable attached to the finger sensor assembly is at the top of the locking opening See Figure 8 Figure 8 ...

Страница 9: ...the door using the Top Mounting Bracket and Bottom Mounting Bracket as show in Figure 9 Do not over tighten the screws in the Bottom Mounting Bracket as this may jam the lock mechanism Attach the lock wire coming out of the Door Interface Box to the back of the lock as shown in Figure 8 The wire will only plug in one way Figure 9 ...

Страница 10: ... used to secure the CAT5 cable that connects the Door Interface Box to the Control Unit Ensure that the door surface is clean and free from any debris Using neat alcohol to clean the surface is highly recommended Allow drying time before proceeding Remove the protective cover from each Tie Down Pad and situate as shown in Figure 10 Figure 10 ...

Страница 11: ...e 11 of 24 Route the CAT5 Cable between Door Interface Box and the Control Unit Route the supplied CAT5 cable as show in Figure 11 Secure the CAT5 cable to the Tie Down Pads using the supplied cable ties Connect the CAT5 cable to the Door Interface Box Figure 11 ...

Страница 12: ...Inc 2011 Page 12 of 24 Connect the CAT5 Cable to the Control Unit Connect the CAT5 cable to the port labeled DOOR 1 on the back of the Control Unit as shown in Figure 12 DO NOT CONNECT THE DOOR INTERFACE BOX CABLE TO THE PORT LABELED NETWORK Figure 12 ...

Страница 13: ...Control Unit to a Network Use the other supplied CAT5 cable to connect the Control Unit to a Network Connect the CAT5 cable to the port labeled NETWORK on the back of the Control Unit as shown in Figure 13 DO NOT CONNECT THE NETWORK CABLE TO THE PORTS LABELED DOOR 1 OR DOOR 2 Figure 13 ...

Страница 14: ...s how to determine which pawl you will need depending on the make and model of cabinet For help with the lock see Southco contact information on pg 3 The pawl is installed as shown in Figure 14 Pay particular attention to the Rotation Limiter This is installed as shown depending on whether you have a right on left hand opening door Figure 14 ...

Страница 15: ...ins 1 thru 8 are used for the Tamper Switches as show in Figures 15a and 15b Figure 15a Figure 15b Tamper Switches are connected to any of the following pair of connector pins 1 2 3 4 5 6 or 7 8 If any of the Tamper Switches are not being used that pair of connectors must be connected with one of the supplied terminating resistors Please wire resistors as show in figure 15c so as to avoid any or t...

Страница 16: ...Model db ServerRack V2 Zero U Digitus Biometrics Inc 2011 Page 16 of 24 Figure 16 ...

Страница 17: ...TION Pins 9 thru 12 are used for the Door Contacts as show in Figures 17a and 17b Figure 17a Figure 17b Door Contacts are connected to either of the following pair of connector pins 9 10 or 11 12 If any of the Door Contacts are not being used that pair of connectors must be connected with one of the supplied terminating resistors Please wire resistors as show in figure 17c so as to avoid any or th...

Страница 18: ...Model db ServerRack V2 Zero U Digitus Biometrics Inc 2011 Page 18 of 24 Figure 18 ...

Страница 19: ...A Duress Finger was used to open a cabinet This will be a silent alarm at the cabinet but will still trigger the Alarm Output The Alarm Output provides a method to connect the db ServerRack Access Control unit to a third party product to alert it that an alarm condition has occurred The Alarm Output terminals are shown in Figures 19a and 19b Figure 19a Figure 19b 12V can be used to provide a 12 Vo...

Страница 20: ...6 bit Wiegand output allowing seamless integration into 3rd party Access Control System The diagram shows how to connect a Control Unit to a 3rd party system The Wiegand Output terminals are shown in Figures 20a and 20b Figure 20a Figure 20b D1 is Data 1 of the Wiegand Output D0 is Data 0 of the Wiegand Output GND is the Wiegand Ground ...

Страница 21: ... can be ordered from your db ServerRack Access Control supplier Connect the CAT5 cable to the port labeled DOOR 2 on the back of the Control Unit as shown in Figure 21 DO NOT CONNECT THE DOOR INTERFACE BOX CABLE TO THE PORT LABELED NETWORK Figure 21 Install the Electro Mechanical Lock Option II The lock is supplied with a 10 cable with a RJ45 connector on one end this connects as shown in Figure 2...

Страница 22: ...Model db ServerRack V2 Zero U Digitus Biometrics Inc 2011 Page 22 of 24 Figure 23 ...

Страница 23: ...erably an Uninterruptable Power Supply UPS Figure 24 Figure 25 The Negative terminal of the Power Supply must be connected to the left terminal as viewed from the rear of the Control Unit The Positive terminal of the Power Supply must be connected to the right terminal as viewed from the rear of the Control Unit IF THE POWER SUPPLY IS WIRED BACKWARDS THE CONTROL UNIT WILL NOT POWER UP THE UNIT HAS...

Страница 24: ...etrics Inc 2011 Page 24 of 24 Digitus Biometrics Inc 2 East Bryan Street Ste 502 Savannah GA 31401 USA Phone 912 231 8175 Fax 912 629 9478 www digitus biometrics com support digitus biometrics com Specifications subject to change without notice ...