5.1. The status LEDs

The  DIGISPEED  is  equiped  with  7  status  LEDs,  that  light  the  terminal
allocation under  the  transparent  sheet  from  behind.  For  every  LED  a  specific
symbol was printed on the connection allocation.

Four LEDs show the actual status of the inputs. These are: 

Inp.1

Inp. 2

Cfg.

1

 and 

Cfg. 2

.

Two more LEDs show the actual status of the outputs. These are: 

Out. 1

 and

Out. 2

.

The last LED named 

Pow.

 displays the devices status.

Device starts.
Status OK.
Error output 1
Error output 2
Error output 1+2

6. Recovery time for the DIGISPEED-DS2

The recovery time for the DIGISPEED-DS2 is needed for the continous recharging of the condenser to
create  the  overload  amplifier  impulse,  since  after  every  initiation  of  such  a  surge  impulse,  the
condenser  has  to  recharge  itself  first.  This  means,  that  between  two  consecutive  overload  amplifier
impulses, you have to wait for at least the time given in the table below.

Current (mA) Ü-Zeit* 1 ms Ü-Zeit* 2 ms Ü-Zeit* 5 ms Ü-Zeit* 10 ms

100

4 ms

8 ms

20 ms

40 ms

200

8 ms

16 ms

40 ms

80 ms

300

12 ms

24 ms

60 ms

120 ms

400

16 ms

32 ms

80 ms

160 ms

500

20 ms

40 ms

100 ms

200 ms

600

24 ms

48 ms

120 ms

240 ms

700

28 ms

56 ms

140 ms

280 ms

800

32 ms

64 ms

160 ms

320 ms

900

36 ms

72 ms

180 ms

360 ms

1000

40 ms

80 ms

200 ms

400 ms

*Ü-Zeit: D

uration of the over-energizing impulse

Ausgabe: August 04

Seite: 12

  2 rue René Laennec 51500 Taissy France

 

Fax: 03 26 85 19 08,  Tel : 03 26 82 49 29

 

E-mail:[email protected]

Site web : www.hvssystem.com

 

 

 

 

 

 

 

 

 

 

 

Содержание DIGISPEED DS1/V2

Страница 1: ...e 3 D 72636 Frickenhausen Tel 49 7022 40590 0 Fax 10 Auf der Langwies 1 D 65510 Hünstetten Wallbach Tel 49 6126 9453 0 Fax 42 Internet http www digitronic com E Mail mail digitronic com 2 rue René Laennec 51500 Taissy France Fax 03 26 85 19 08 Tel 03 26 82 49 29 E mail hvssystem hvssystem com Site web www hvssystem com ...

Страница 2: ...ble for loss of profits forfeited savings intermediate and successive damages 2 The above mentioned limits to liability do not apply to insurance of named characteristics and damages which were caused deliberately or through negligence Protection The DIGISPEED and this instruction manual are protected by copyright All rights are reserved Neither the DIGISPEED nor this document may be copied as a w...

Страница 3: ... in DIGISPEED 7 4 1 Switching mode 1 factory preset 7 4 2 Switching mode 2 8 4 3 Switching mode3 9 4 4 Switching mode4 10 4 5 Configuration of the switching modes at DIGISPEED DS1 V2 11 5 Commisioning 11 5 1 The status LEDs 12 6 Recovery time for the DIGISPEED DS2 12 7 Terminal allocartion 13 8 Examples for connection 13 9 Dimensions 14 10 Technical Data 14 Ausgabe August 04 Seite 3 2 rue René Lae...

Страница 4: ...accelerates the dismantleling of the magnetic fieldusing a flywheel circle of 26V DC and causes a decreasing switching off time Result By time interval controlled overload impulsesin connection with the regulationof the flywheel voltage to 56V DC the DIGISOFT causes magnetically influenced switching links to work with tenth the speed 2 Attributes Microprocessor controlled perfomance electricity fo...

Страница 5: ...is able to antagonize the spring s force Now the switching movemeent is initialized This is finished at 41ms At the moment of 50ms the procedure of switchingboff begins The built in flywheeling diod causes a flywheeling voltage of 0 7V DC so that the flywheeling current de establishes the magnetic field slowly At 71 ms the spring s force is greater than the magnetic force so that the switching off...

Страница 6: ...he switching off is done at the moment of 50ms without flywheeling iode the flywheelingcurrent is set to 56V DC by the DIGISPEED This enables de establishing the magnetic force very quickly At 53ms the spring s power has allready overcome the magnetic force so that the switching off movement can be initialized At 67ms it is allready finished Important To use the reguzlated flywheeling circle s eff...

Страница 7: ...on out of an PLC controll 4 1 Switching mode 1 factory preset Switching mode 1 is the DIGISPEED s standard mode over energ over energ impuls Length Time Diagram Input 3 Input 4 Duration of the overenergizing impulse 0 VDC 0 VDC 1 ms 24 VDC 0 VDC 2 ms 0 VDC 24 VDC 5 ms 24 VDC 24 VDC 10 ms Ausgabe August 04 Seite 7 2 rue René Laennec 51500 Taissy France Fax 03 26 85 19 08 Tel 03 26 82 49 29 E mail h...

Страница 8: ...includes an enableling input E3 AND Linkage over over energ energ Impul length Time Diagram Input 4 Duration of the overenergizing impulse 0 VDC 2 ms 24 VDC 5 ms Ausgabe August 04 Seite 8 2 rue René Laennec 51500 Taissy France Fax 03 26 85 19 08 Tel 03 26 82 49 29 E mail hvssystem hvssystem com Site web www hvssystem com ...

Страница 9: ...DC 1 ms 24 VDC 0 VDC 2 ms 0 VDC 24 VDC 5 ms 24 VDC 24 VDC 10 ms Input 2 Pause 0 VDC Ü Zeit x 2 24 VDC Ü Zeit x 1 Ü Zeit Duration of the over energizing impulse Pause Time between the switching off of coil 1 and the switching on off coil 2 or vice versa It canb be calculated by multiplying the Ü Zeit with 2 or 1 Ausgabe August 04 Seite 9 2 rue René Laennec 51500 Taissy France Fax 03 26 85 19 08 Tel...

Страница 10: ...n wire security for the reset input over over length length Impuls length Time diagram Input 3 Input 4 Duration of the over energizing impulse 0 VDC 0 VDC 1 ms 24 VDC 0 VDC 2 ms 0 VDC 24 VDC 5 ms 24 VDC 24 VDC 10 ms Ausgabe August 04 Seite 10 2 rue René Laennec 51500 Taissy France Fax 03 26 85 19 08 Tel 03 26 82 49 29 E mail hvssystem hvssystem com Site web www hvssystem com ...

Страница 11: ...rease the overenergizing time in small steps 8regarding the recovery time until no further improvement of switchimng behaviour can be detected Thenb switch back to the last overenergizing time with a detectable improvement of the switching behaviour To run the unit with a higher load does not make any sense since it only causes a quicker using up An optimal adjusted over energizing time on the con...

Страница 12: ... the continous recharging of the condenser to create the overload amplifier impulse since after every initiation of such a surge impulse the condenser has to recharge itself first This means that between two consecutive overload amplifier impulses you have to wait for at least the time given in the table below Current mA Ü Zeit 1 ms Ü Zeit 2 ms Ü Zeit 5 ms Ü Zeit 10 ms 100 4 ms 8 ms 20 ms 40 ms 20...

Страница 13: ...Terminal 7 output 1 Terminal 8 output 2 Terminal 9 24V DC 20 supply voltage a minimum of 5 0 Amp Terminal10 Do not connect for the internal condensors discharging only 8 Examples for connection Note The picture shows an DIGISPEED DS1 V2 set to 5ms over energizing time without galvanical separation at an S5 PLC Ausgabe August 04 Seite 13 2 rue René Laennec 51500 Taissy France Fax 03 26 85 19 08 Tel...

Страница 14: ... Output voltage Supply voltage 1V at 1A permanent current bei 24V DC min 23V DC Output current 1A permanent current per output resistant against short circuits Delay times max 100µs Recovery times see chapter recovery times Cover hardly ignitable Thermoplast plastic continous temperature up to 100 C Conductor allocation five solid screw clamps up to 2 5mm in the structural module of 5 08mm with la...

Отзывы: