Special Instructions for DB210/DB220 Op Switches 39 and 40
For these Op Switches to work properly,
1. Set the OpSw to “
c
” by pressing the
CLOC / c
key.
2. Set the DB210/DB220’s
MODE
Switch to “
SLEEP
” mode.
3. Set the DB210/DB220’s
MODE
Switch back to “
RUN
” mode.
4. The operation will occur (data will be cleared) and the option switch will
reset to “
t
”.
5. Your
throttle display will still show “
c
” even though the reset has
occurred.
6. The display will update the next time you access the OpSw.
7.2 DB210/DB220 Option Switch Tables
The following tables provide a list of the DB210/DB220 Option Switches and
the impact of the change on the system.
DB210/DB220 Option Switch Tables
Option
Switch #
Effect on System operation
Factory
Default
OpSw 05**
c =
Enter Voltage trim Mode
t
OpSw 18
t =
Normal DB210/DB220 booster short circuit shutdown time
t
c =
Extended DB210/DB220 booster short circuit shutdown time
OpSw 39*
c =
Clears all internal memory states
t
OpSw 40*
c =
Clears all internal memory states and sets Voltage Trim to default.
Resets DB210/DB220 to factory default
t
DB210/DB220 Option Switch Tables
*See special instructions in
above
for setting OpSw 39, and 40.
** See special instructions in
Section 4.10.1
for setting Voltage Trim.