background image

-

5

-

Changing Transmitter Frequency Band

Switch between frequency bands during pre-bore calibration or mid-bore to
overcome interference.

A frequency band remains selected on both the receiver and transmitter even
after a power cycle.

Above Ground – Power-On Method

Insert transmitter (Tx) batteries with the Tx pointing down (battery
compartment on top, shown at right) to power on in the Down band.
Insert batteries with the Tx pointing up to power on in the Up band.

Above Ground – Tilt Method

Let Tx sit powered on at level (0±10°) for at least five seconds
(sec.), tilt Tx up at approx. +65° (almost vertical) for 10–18 sec.,
then return to level for 10–18 sec., maintaining ±2 clock position
(CP) during this sequence. When the Tx changes bands, data
disappears from the receiver.

Below Ground (Mid-Bore) – 10/2/7 Roll Method

Disable Roll Offset (if enabled). Roll the Tx clockwise (CW) to a CP of 10±1 and
wait 10–18 sec., slowly roll CW to CP 2±1 and wait 10–18 sec., and slowly roll CW
to CP 7±1. The Tx changes bands within 20 sec. and data disappears from the
receiver. Re-enable Roll Offset if applicable.

Below Ground (Mid-Bore) – RRS Roll Method

Remain at any CP for at least 40 sec. to clear timers. Complete one full CW
rotation (±2 CP) within 1–30 sec., wait 10-18 sec., and repeat twice for a total of
three rotations (RRS3). The Tx changes frequency band within 60 sec.

Changing Receiver Frequency Band

If you change bands on your transmitter, you must also do so on the receiver. At
the Main menu, select

Settings

>

Transmitter Options

and choose the other

frequency band. Return to the Locate screen, where data should begin displaying
as transmission resumes in the new band.

Содержание Falcon F2

Страница 1: ...Receiver Locate Screen 1 Locate point ball 2 Receiver 3 Roll indicator 4 Roll pitch update meter 5 Transmitter Tx pitch 6 Tx signal strength 7 Tx temperature Transmitter and receiver must be Paired be...

Страница 2: ...yed walk the receiver along the bore path while observing the noise readings and mark those points where significant changes occur X If noise levels rise substantially atany pointalongthe bore conside...

Страница 3: ...teries and endcap the increase in FO noise readings shows the Tx is on 5 Select Pair flashing 6 Position the transmitter s infrared IR port within five cm of the receiver s IR port 1 IR port 7 Select...

Страница 4: ...mbol will display in the roll indicator on the Locate screen until a1 pointcalibration is completedfor the current band Settings Menu Use the Settings menu to set the depth units pitch units roll offs...

Страница 5: ...nds data disappears from the receiver Below Ground Mid Bore 10 2 7 Roll Method Disable Roll Offset if enabled Roll the Tx clockwise CW to a CP of 10 1 and wait 10 18 sec slowly roll CW to CP 2 1 and w...

Страница 6: ...mer is full l Always take three Max Mode readings all must be consistent See the system operator s manual for additional important information on the use of this feature Signal Attenuation An Aicon ma...

Страница 7: ...depth by holding the trigger at the LL on the line between the FLP and RLP 5 Holding the trigger longer than five seconds enables Max Mode see page 6 Transmitter Signal Field Geometry Level Transmitt...

Страница 8: ...view 3 Line in the Box at LL 4 HAG on 5 Max Mode timer 6 Max Mode icon 7 Tx depth Depth Screen Trigger held at FLP 1 Reference indicator 2 Ball in the Box at FLP only 3 Roll pitch update meter 4 Tx pr...

Отзывы: