D
IGITAL
C
ONTROL
I
NCORPORATED
18
DigiTrak Falcon F1™ Operator's Manual
Set HAG Value
Set HAG Value
Use the
Set HAG Value
screen to input the height at which the receiver will be held above the ground when
HAG is on.
A question mark initially appears in place of the HAG value.
Hold the trigger briefly to set the HAG value. The current or default HAG setting displays in place of the
question mark. Click to scroll through the available height-above-ground values of 12 to 36 in., then hold the
trigger at the desired HAG value. The receiver beeps and confirms with a check mark, then enables HAG and
returns to the Locate screen.
Depth readings (holding the trigger) must now be taken with the receiver held at this height.
As noted above, to prevent incorrect readings, HAG must be turned on manually each time after the receiver
is powered on or calibrated.
Calibration and AGR
Use the
Calibration
menu to calibrate the receiver to a transmitter and to verify the Above Ground Range
(AGR). Calibration is required prior to first-time use, after frequency optimization, and before using a different
transmitter, receiver, or drill head.
Calibrate after optimizing
If your optimized band has not been calibrated yet,
appears in the roll indicator. After
optimizing, calibrate and verify Above Ground Range prior to each job. Calibration affects depth
readings, but not roll/pitch.