5
Indoor Use
This battery charger is designed for indoor use only and should not come into contact with
water or extreme dust. To avoid overheating, do not cover the charger while in use. Using it
to charge any other type of battery other than a DCI battery pack can result in damage and
void the battery charger warranty.
System Specifications
The power requirements, environmental requirements, and equipment maintenance
requirements for the FBC F Series Battery Charger are listed below.
Power Requirements
Device (Model Number)
Operational Voltage
Operational Current
DigiTrak F Series Battery
Charger (FBC)
Input 10
–28 V
Output 19.2 V
5.0 A max
1.8 A max
Environmental Requirements
Device
Relative Humidity
Operating Temperature
DigiTrak F Series Battery
Charger (FBC)
<99% for 32
–50° F
<95% for 50
–95° F
32 to 95° F
DigiTrak F Series Lithium-Ion
Battery Pack (FBP)
<99% for <50° F
<95% for 50
–95° F
<75% for 95
–140° F
-4 to 140° F
System working altitude: up to 6561 ft.