DIGITEN DHTC-1011 Скачать руководство пользователя страница 6

Note: Before setting the parameters, please don’t connect any 
load (whether it is heating / cooling equipment, or humidification / 

dehumidification equipment).

For example

Turn on the heater at 76°F and turn off at 80°F, turn on the humidifier at    
40% humidity and turn off at 50%.

1. Press and hold the SET button for about 3 seconds until the   
appears.
2. Short press the SET button to select the temperature.
3. Press the   and   button to set the RV to 76°F.
4. Short press the SET button to the SV value page.

Long press SET
button for 3s

Run temperature

Stop temperature

Alarm low temperature

Alarm high temperature

Compressor Delay
time(mintures)

Temperature
Calibration

SET

SET

SET

SET

SET

SET

Long press SET
button to save

Run value

Stop value

Alarm high humidity

Alarm low humidity

Humidity Calibration

SET

SET

SET

SET

Long press SET
button to save

Setup Flow Chart

Содержание DHTC-1011

Страница 1: ...Temperature and Humidity Controller Model DHTC 1011 www digit en com service digit en com...

Страница 2: ...100 240VAC Input Power Cable Length 120 cm 4ft Output Power Cable Length 30cm 6 5 Feature Large LCD screen Dual relay output be able to control heating cooling equipment and humidification dehumidific...

Страница 3: ...on OFF Loading working status is off HI High temperature humidity alarm value LO Low temperature humidity alarm value Setting Instruction View the setting value Short press the SET button and you can...

Страница 4: ...ns that the cooling equipment is in the delayed start protection state When PV SV the green light will go out and the cooling equipment will stop working 1 Long press the SET button until the appears...

Страница 5: ...ppears and the flashes 2 Short press the UP or DOWN button and there will be a flashing then press the SET button to select the Humidity 3 Press UP or DOWN to adjust the RUN value you required 4 Short...

Страница 6: ...l the appears 2 Short press the SET button to select the temperature 3 Press the and button to set the RV to 76 F 4 Short press the SET button to the SV value page Long press SET button for 3s Run tem...

Страница 7: ...rature humidity alarm value 4 0 1 2 0 C 4 0 2 4 8 F 0 RH 99 RH 40 C 5 RH DP Time of compressor Delay Starting 0 10minutes 0minutes CA Temperature Humidity Calibration 1 5 1 5 C 1 5 1 5 F 10 RH 10 RH 0...

Страница 8: ...ht is on but the load does not work When energized the PV is exactly within the RV and SV which meets your requirements so the load device doesn t need to be turned on at this time Err Alarm When the...

Отзывы: