Note: 

After changing the temperature unit, all setting values will be 

restored to the factory settings.

Indicator light:

The indicator light on the left of the panel is for Temperature, and the 
right one is for Humidity. Each light is a two-color light that are red and 
green. The red light indicates stop working, and green one means 
running.

Set cooling mode:

To set the RV(RUN temperature) > SV(STOP temperature), the system 
will be in cooling mode and the  

 will appear on the 

display. 
When PV (Measuring temperature) > RV, the green indicator of 
TEMPERATURE will be on and the cooling equipment will work. (If 

the RUN value flashes, it means that the cooling equipment is in the 

delayed start protection state.)

When PV ≤ SV, the green light will go out and the cooling equipment 

will stop working.
1. Long press the SET button until the   appears and the 

 flashes.

2. Short press the   or   button and there will be a 

 flashing, then 

press the SET button to select the temperature.
3. Press   or   to adjust the RUN temperature you required.
4. Short press SET button to set STOP temperature and next value.
5. Long press SET button to save and exit.

Set heating mode:

To set the RV(RUN temperature) < SV(STOP temperature), the system 
will be in heating mode and the 

 will appear on the 

display. When PV(Measuring temperature) < RV, the green indicator of 
TEMPERATURE will light and the cooling equipment will work.

When PV ≥ SV, the green light will go out and the heating equipment 

will stop working.

Содержание DHTC-1011

Страница 1: ...Temperature and Humidity Controller Model DHTC 1011 www digit en com service digit en com...

Страница 2: ...100 240VAC Input Power Cable Length 120 cm 4ft Output Power Cable Length 30cm 6 5 Feature Large LCD screen Dual relay output be able to control heating cooling equipment and humidification dehumidific...

Страница 3: ...on OFF Loading working status is off HI High temperature humidity alarm value LO Low temperature humidity alarm value Setting Instruction View the setting value Short press the SET button and you can...

Страница 4: ...ns that the cooling equipment is in the delayed start protection state When PV SV the green light will go out and the cooling equipment will stop working 1 Long press the SET button until the appears...

Страница 5: ...ppears and the flashes 2 Short press the UP or DOWN button and there will be a flashing then press the SET button to select the Humidity 3 Press UP or DOWN to adjust the RUN value you required 4 Short...

Страница 6: ...l the appears 2 Short press the SET button to select the temperature 3 Press the and button to set the RV to 76 F 4 Short press the SET button to the SV value page Long press SET button for 3s Run tem...

Страница 7: ...rature humidity alarm value 4 0 1 2 0 C 4 0 2 4 8 F 0 RH 99 RH 40 C 5 RH DP Time of compressor Delay Starting 0 10minutes 0minutes CA Temperature Humidity Calibration 1 5 1 5 C 1 5 1 5 F 10 RH 10 RH 0...

Страница 8: ...ht is on but the load does not work When energized the PV is exactly within the RV and SV which meets your requirements so the load device doesn t need to be turned on at this time Err Alarm When the...

Отзывы: