background image

 

Installation  Step 3 – Powering the  WLN20 

 

Provide power connections to the unit. Power is connected to the ten core 
PWR/DATA cable on the Red and Black wires. Red wire is the positive (+) 
connection, Black wire is the negative (-) connection. 

 

Connect the stripped wires to the nearest source of primary 12V or 24V DC 
power. Ensure that the supply is connected via a 1A fuse (not supplied) or 
suitable circuit breaker. The fuse should be fitted in the positive power 
connection to the unit if necessary. 

 

Installation  Step 4 – Interfacing (NMEA) 

 

The WLN20 device allows full bi-directional, wireless NMEA0183 data 
communication to occur between two suitable devices. In most insta llations, 
it is likely that the communication will be in one direction i.e. NMEA 0183 
data from an instrument system being wirelessly transmitted to an 
iPhone/iPad application.  

 

The WLN20 has two NMEA0183 inputs; Port 1 is a high speed 38400 baud 
port for connection to an AIS or other high speed device, whilst Port 2 is a 
conventional low speed 4800 baud port for connection to legacy GPS and 
Instrument Systems. 

 

Below is a diagram of a typical WLN20 installation; 

 

 