AMBE-20x0™-HDK Development Board
User’s Manual
(Preliminary)
Page 25
DVSI Confidential Proprietary
Section 4 – Communication via Channel Interface
After making a selection press “*” and the board will print to screen new HDK board current settings.
Current RS-232 Baud Rate = XXXXXX
Current Format = XXXXX Packet
Option Name
Description
RS-232 Channel Baud Rate Configuration Options (A)
0
4800 baud
1
7200 baud
2
9600 baud
3
14400 baud
4
19200 baud
5
28800 baud
6
38400 baud
7
57600 baud
8
76800 baud
9
RS-232 Channel Rate
115200 baud
Packet Format Options (B)
0
HDK Format
Sync word and data only
1
AMBE-2000™ Packet Format
(
default setting
)
Full AMBE-2000™ Vocoder Chip Packet
Connecting the RS-232 Channel I/O to a PC
Demonstration Software
The CD included with the HDK kit includes a PC executable program (ambe_hdk.exe) that enables the
user to, compress and record analog speech input data to a PC, or decode a previously encoded file and
play it out of the analog outputs.
The AMBE-20x0™-HDK Development Board software includes the following exe file that should be
copied from the CD into a user created directory the located on a C-drive named \hdk:
ambe_hdk.exe
Also included on the HDK CD disk are sample files of compressed speech files recorded at various rates
as well as PCM files that may be played through a PC’s sound card and input into the audio in to create
your own recorded files.