Summary: Jumpers setting
Ref
Purpose
Note
JA2
Fans Power select
24V Power input
– Short 24V-IN, Open 12V-IN
12V Power input
– Open 24V-IN, Short 12V-IN
JA3
Panel power voltage select
CAUTION
: Incorrect setting can damage
panel
See panel voltage setting table 1
JA5
Panel power voltage select
CAUTION:
Incorrect setting will cause panel
damage
See panel voltage setting table 1
JA6
Panel power voltage select
CAUTION:
Incorrect setting will cause panel
damage
See panel voltage setting table 1
JA15
Panel power output control via J7 (pin 1-8)
and J6 (pin 5-9)
1-3, 2-4 = Enable panel power (3.3/5V) output on J7 and
J6
3-5, 4-6 = Enable panel power (10/12/18/24V) output on
J7 and J6
Open = Disable panel power output on J7 and J6
JB1
Backlight brightness voltage range
1-2 = 5V max
2-3 = 3.3V max
JB2
Backlight inverter on/off control
– signal level 2-3 = On/Off control signal ‘High’ = +5V
1-2
= On/Off control signal ‘High’ = +3.3V
Open = On/Off control signal ‘High’ = Open collector
CAUTION
: Incorrect setting can damage inverter.
JB3
Backlight inverter on/off control
– polarity
1-
2 = control signal ‘high’ = Backlight ON
2-
3 = control signal ‘low’ = Backlight ON
JB4
Reserved for LVDS (J3) GPIO pins voltage
selection
1-2 = 3.3V
2-3 = 5V
JB5
Backlight control type selection
1-2 = VR/Digital switch mount control
3-4 = Analog backlight brightness - voltage range 0~5V
5-6 = PWM (Pulse Width Modulation) brightness
JB7
Backlight control voltage on CNB1 pin 4
(Function when JB5 sets 1-2 closed)
Open = For OSD switch mount control (Default)
1-2 = 0V
2-3 = 3.3V / 5V controlled by JB1
JB13
V-by-One / eDP selection on J7
1-2 = V-by-One
2-3 = eDP (1.1)
JB14
V-by-One / eDP selection on J7
1-2 = V-by-One
2-3 = eDP (1.1)
JP1
Factory use
Default Open
JP2
V-by-One power output configuration
1-2 = All pin 44 ~ pin 51 on J7 have power output
Open = Only the upper four pins have power output
(Refer to power output enabled/disabled on JA15. But
not applicable if JA15 is set to OPEN)
JP6
Input power control
Short = External switch control and fix the board ON
Open = Switch mount control