OSD H position
0x90,
nn | “+” | “-” |
“r” | “R” |
“?”
Set OSD horizontal position =
value/increment/decrement
Reset
Query
nn = 0x00~ 0x64 (left ~ right)
Default: 0x32 (middle)
OSD V position
0x91,
nn | “+” | “-” |
“r” | “R” |
“?”
Set OSD vertical position =
value/increment/decrement
Reset
Query
nn = 0x00~ 0x64 (top ~ bottom)
Default: 0x32 (middle)
OSD transparency
0x92,
nn | “+” | “-” |
“r” | “R” |
“?”
Set OSD transparency =
value/increment/decrement
Reset
Query
nn = 0x00~ 0x64 (0~100%)
Default: 0x00 (No transparency)
OSD menu timeout 0x93,
nn | “+” | “-” |
“r” | “R” |
“?”
Select menu timeout =
value/increment/decrement
Reset
Query
OSD menu timeout value.
nn = 0x00 – Always on
nn = 0x0A - 0x3C (10~60sec)
Default: 0x0A (10sec)
Select OSD
language*
0x95,
n |
“r” | “R” |
“?”
Select language =
English, Chinese,…
Reset
Query
“0” – English (Default)
“2” - French
“3” – Spanish
GAMMA value
select
0x9d,
n |
“r” | “R”
“?”
Select GAMMA value =
Value
Reset
Query
“n”:
“5” – 1.8,
“7” – 2.0,
“2” – 2.2, (Default)
“A” – 2.4
“C” – 2.6
Runtime counter
0xa1,
nnnnn |
“r” | “R” |
“?”
Set runtime counter value =
nnnnn (* 0.5 hour)
Reset to zero
Query
Runtime = nnnnn.
Max. input = 0x1fffe (0x1fffe * 0.5 hour
= 65535 hours)
Runtime counter counts when backlight
is on
Colour temperature
select
0xb3,
n |
“r” | “R” |
“?”
Select colour temperature =
value
Reset
Query
“n” =
“2” – 6500K. (Default)
“4” – User
“5” – 9300K
“6” – 7500K
“7” – 5800K
“8” – sRGB
Red level of User
colour temperature
0xb4,
nn | “+” | “-” |
“r” | “R” |
“?”
“m”
“n”
Set the level of the red channel
for the user colour temp. =
value/increment/decrement
Reset
Query
Maximum query
Minimum query
nn: 0x00~ 0xff (0~255)
Default: 0x80
Green level of User
colour temperature
0xb5,
nn | “+” | “-” |
“r” | “R” |
“?”
“m”
“n”
Set the level of the green
channel for the user colour temp.
=
value/increment/decrement
Reset
Query
Maximum query
Minimum query
nn: 0x00~ 0xff (0~255)
Default: 0x80
Blue level of User
colour temperature
0xb6,
nn | “+” | “-” |
“r” | “R” |
“?”
“m”
“n”
Set the level of the blue channel
for the user colour temp. =
value/increment/decrement
Reset
Query
Maximum query
Minimum query
nn: 0x00~ 0xff (0~255)
Default: 0x80