Digital Monitoring Products Canadain XR500 Скачать руководство пользователя страница 1

Содержание Canadain XR500

Страница 1: ......

Страница 2: ...er code or present your card to a keypad or reader during the Status List display All Perimeter Home Sleep Away or Home Sleep Away with Guest System CANCEL VERIFY displays If a burglar alarm is valid...

Страница 3: ...4 Power Armed LED 4 Thinline and Aqualite Keypads 4 Clear Touch Keypads 4 Power Armed Logo 4 Thinline Wireless Keypads 4 Panic Functions 5 Thinline Aqualite and Wireless Keypads 5 Clear Touch Keypads...

Страница 4: ...m 20 Home Sleep Away and Home Sleep Away with Guest System Disarming 20 Disarming a Home Sleep Away or a Home Sleep Away with Guest System 21 Disarming During an Alarm 21 Extending Schedules 21 Keypad...

Страница 5: ...the System s Date and Time 41 Display Events 42 Service Request 42 Fire Drill 43 Starting a Fire Drill test 43 Ending a Fire Drill test 43 System Setup 44 System Setup Record 44 Keypad Record 44 Key...

Страница 6: ...E 63 Easy Entry User s Guide 63 Door Strike 63 Arming and Disarming an Area System 63 Arming and Disarming an All Perimeter System 64 Arming and Disarming a Home Sleep Away System and a Home Sleep Awa...

Страница 7: ...he System Test section of this guide for instructions on testing the burglary portion of your system and refer to the Fire Drill section for instructions on testing your system fire bells XR500 and XR...

Страница 8: ...he floor plan to show escape routes from each room Decide Where to Meet Prearrange a meeting place outside and away from where emergency personnel are likely to be working A neighbor s house or across...

Страница 9: ...Select Keys 1 2 3 4 9 0 CMD 5 6 7 8 ABC PRINTING FRI 2 51 AM Backlit Logo and Proximity Antenna Thinline Aqualite Keypad AC Power Armed LED Three Panic Icons 32 Character Display with Four Touch Sele...

Страница 10: ...Alternate Panel Armed AC Power OK Battery Fault Red Blinking Panel Armed AC Power Fault Battery OK The Select keys Thinline Aqualite and Wireless Keypads There are four keys under the display called...

Страница 11: ...e Keypads may also be programmed at installation to allow the user to initiate an optional Panic alarm by simultaneously pressing and holding the 7 and 0 zero keys When the 7 and 0 keys are pressed fo...

Страница 12: ...rough 32 display on four separate displays First areas 1 through 8 display Press the COMMAND key to display areas 9 through 16 Press the COMMAND key again to display areas 17 through 25 Press the COMM...

Страница 13: ...backlighting brightness level Internal Speaker Tone Set the tone of the keypad internal speaker At the SET TONE display use the top left Select key to make the tone lower Use the right Select key to m...

Страница 14: ...the trouble tone sounds You can silence the trouble tone by pressing any key This only silences the keypad and does not correct the condition that originally caused the trouble DMP Wireless Your syste...

Страница 15: ...ection device or system component This display is accompanied by a description of the problem ALARM NOT SENT The alarm signal was aborted and was not sent to the central station because a user code wa...

Страница 16: ...n or service technician Email Cell Phone Messages Your system may be programmed at installation to send a variety of messages to your personal email PDA and cell phone The message option uses your sec...

Страница 17: ...ouped together under the same zone name and number Often similar devices in the same general location share the same zone For example the windows on the east side of the premises can all be grouped to...

Страница 18: ...checking the armed areas If your system is set up as a Home Sleep Away or All Perimeter system one of the following displays indicate the current Armed Status The keypad displays When HOME SYSTEM ON...

Страница 19: ...the zone can be repaired by a service technician A force armed zone is ignored by the system until it restores to normal A bypassed zone is ignored by the system during the entire armed period A zone...

Страница 20: ...if you re enter during the countdown the exit countdown restarts allowing additional time to then disarm or again exit the building during the countdown This restart can occur only one time When the...

Страница 21: ...nt you can force arm or bypass any faulted zones A zone that is force armed is restored into the system if it later returns to normal A zone that is bypassed remains bypassed until the system is disar...

Страница 22: ...rewarn tone begins sounding again Schedules If you have programmed schedules for your system and a code is entered outside of a schedule and that code does not have authorization to disarm outside of...

Страница 23: ...curity system is divided into two separate areas Motion detectors inside doors and other interior protection devices are assigned to the Interior area while windows and exterior doors are assigned to...

Страница 24: ...tion This is optional and can be programmed for you at any time Arming an All Perimeter System 1 Enter your 4 digit user code The keypad displays PERIM ALL 2 Select PERIM to arm the Perimeter area onl...

Страница 25: ...rs and other interior devices are assigned to an Interior and Bedroom areas while windows and exterior doors are assigned to a Perimeter area Arming the system When arming a Home Sleep Away or a Home...

Страница 26: ...EST 1 or 2 ON if you selected AWAY 8 The keypad next displays EXIT INSTNT and begins to count down the number of seconds remaining for you to exit When the delay expires the exit zones are armed 9 You...

Страница 27: ...and cancel the alarm The keypad next displays ALL SYSTEM OFF to confirm the system is disarmed OR If the alarm is valid select VERIFY to send a verify message to the Central Station Extending Schedule...

Страница 28: ...e faulted select force arm or bypass Refer to the Arming Section for detailed arming operation Home Sleep Away and Home Sleep Away with Guest Arming Arm Home Press 3 for 2 seconds to arm the perimeter...

Страница 29: ...ate OUTPUTS ON OFF Allows you to turn on or off any of the outputs described in the System Setup section of this guide ZONE STATUS Allows you to see if a zone is either armed bypassed in alarm open or...

Страница 30: ...ower to the detectors is temporarily removed by the system allowing them to reset Make sure all smoke is cleared from around the area of the smoke detectors before performing a Sensor Reset to prevent...

Страница 31: ...s assigned to the keypad INVALID AREA displays when your user code does not have access to the keypad s areas and the output does not turn on Under certain conditions some outputs cannot be turned on...

Страница 32: ...s bypassed BAD the zone is in a bad or faulted condition 9 After displaying the zone status ZONE returns for you to enter another zone number Browser Feature If you are unsure of the zone number or de...

Страница 33: ...r using the System Test function place all zones in Zone Monitor Starting at the front door go around and open and then close each door and window You should hear the keypad beep each time The keypad...

Страница 34: ...ce 4 The system then displays its firmware version the panel mode and then exits the User Menu For example VER_118_1 20 07 MODEL XR500 System Test System Test is used to test the battery alarm bell or...

Страница 35: ...everal characteristics define the authority of each User Profile within the system Always make sure that at least one administrator in your system has a profile with all authorities and all areas In A...

Страница 36: ...nd press the COMMAND key to advance to the next menu Selection 9 When you have completed selecting all User Profile menu assignments the keypad displays the PROFILE ADDED message for 4 seconds Browser...

Страница 37: ...E This menu option defines the time schedules that the User Code operates for door access and disarming Selecting 1 2 3 and or 4 indicates operation during the S1 S4 shift schedules Selecting ANYTIME...

Страница 38: ...s Yes Yes No No Yes BYPAS ZN NO YES Bypass Zones No No No No No Yes Yes Yes Yes No No Yes ZONE MON NO YES Zone Monitor No No No Yes Yes Yes Yes Yes Yes No No Yes SYS STAT NO YES System Status Yes Yes...

Страница 39: ...s also assigned a Profile 1 to 99 by the person administrating the system The profile number determines the areas and functions the user can access Adding User Codes 1 Access the User Menu 2 Press COM...

Страница 40: ...Change User Codes browser 9 At the PROFILE NO display enter a profile number from 1 to 99 and press COMMAND The displays shows USER ADDED If BAT Batch was chosen in step 4 instead of ADD the next ava...

Страница 41: ...ep 3 for the next user Press the Back Arrow key to exit this menu Deleting User Codes 1 Access the User Menu 2 Press COMMAND until USER CODES displays 3 Press any Select key The keypad displays ADD DE...

Страница 42: ...the system Having separate schedules allows you to create Opening Closing windows for each day One could be for normal business activity and another could be for cleaning crews or a second shift Once...

Страница 43: ...AND until SCHEDULES displays Press any Select key 2 The keypad displays S1 S2 S3 S4 Select the shift you want to program This allows you to enter a schedule that remains in place until you change or d...

Страница 44: ...key to exit the User Menu Note Your system may be programmed to limit the Panic Zone Test to only be performed during the Area 32 Shift 4 schedule Setting Output OUT and Door DOOR Schedules The Schedu...

Страница 45: ...or to go back to the S1 S2 S3 S4 display press the Back Arrow key Setting Holiday ABC Schedules for S1 S2 S3 S4 OUT and DOOR Schedules Three Holiday schedules are available for each shift S1 S2 S3 S4...

Страница 46: ...n the normal opening and closing schedules are not used and superseded by one of the Holiday Schedules A or B or C When the panel determines that it is a holiday the Holiday Schedule supersede the cur...

Страница 47: ...dule for greater than one hour Press AM or PM Note If the system is not armed by the scheduled closing time a Late to Close report is sent to the central station If the schedule is extended a Schedule...

Страница 48: ...ast door access and system events There are six event types Zone Activity Zone alarms troubles and restorals Opening and Closing System arming and disarming User Code Adding deleting and changing user...

Страница 49: ...age to the central station Starting a Fire Drill test 1 Access the User Menu 2 Press COMMAND until FIRE DRILL displays Press any Select key 3 The keypad displays SURE YES NO 4 Select YES to start the...

Страница 50: ...Your system sends Ambush reports Yes No Your XR500E system uses Card Plus PIN operation Yes No System Setup Keypad Record Note XR500 systems support 16 keypad devices XR100 systems support 8 keypad de...

Страница 51: ...pads provide Door Access reports 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 N A Key Fob Button Programming Enter the user name assigned to each key fob and the button action programmed for each button in...

Страница 52: ...be divided into 8 separate areas All Perimeter systems are divided into two separate areas Home Sleep Away and Home Sleep Away with Guest systems are divided into two or three separate areas Each area...

Страница 53: ...e Profile Name Arm Disarm Areas Access Areas Output Group Arm Disarm Alarm Silence Sensor Reset Door Access Armed Area Outputs On Off Zone Status Bypass Zones Zone Monitor System Status System Test Us...

Страница 54: ...rrent user codes you can keep track of their profile number in the system Use the following table to track custom user codes in your system Only 4 digit user codes can be assigned to All Perimeter Hom...

Страница 55: ..._M _M _M _M _M _M _M _M _M _M _M _M _M _M _M _M S1 S2 S3 S4 Area Open Close _M _M _M _M _M _M _M _M _M _M _M _M _M _M _M _M _M _M _M _M S1 S2 S3 S4 Area Open Close _M _M _M _M _M _M _M _M _M _M _M _M...

Страница 56: ...ice names Output Output Name ___________ ________________________________________ ___________ ________________________________________ ___________ ________________________________________ ___________...

Страница 57: ...beginning date for the sort Press COMMAND 5 The keypad displays LAST DATE 10 17 Press any Select key and enter a 4 digit ending date for the sort Press COMMAND 6 The keypad displays USER NUMBER To sor...

Страница 58: ...t SVC Service smoke detector LOW Low battery MIS Missing wireless transmitter Note LOW and MIS are for wireless systems only Supervisory Event Displays This displays the date and time of an automatic...

Страница 59: ...of the person granted access Keypad Display Description acc 5 18P 10 17 3 user 024 User 24 accessed door keypad 3 at 5 18 PM on October 17 Press the first Select key to display the Door name where th...

Страница 60: ...r 024 to display the user name Wireless Jamming Event Displays This displays wireless jamming events that have occurred Keypad Display Description ALM 11 41A 10 17 WIRELESS The DMP wireless receiver d...

Страница 61: ...ire Panic Supervisory etc Press the COMMAND key to scroll through the zone names list EAST DOOR When the correct zone name displays press any SELECT key area ZONE NO 0 1 2 Verify the zone number match...

Страница 62: ...the zone SELECT BYP to Bypass the zone ZONE RST BYP The display returns to the ZONE prompt allowing you to enter another zone number CMD CMD Zone Monitor Browser SELECT ZONE Access the User Menu Pres...

Страница 63: ...SER NUMBER 12 CMD CMD CMD Change User Codes Browser USER CODES ADD DEL CHG USER NUMBER 1 2 4 3 MIKE JONES Access the User Menu Press COMMAND until USER CODES displays SELECT CHG At this prompt you can...

Страница 64: ...ITH The next available user name displays If this is the user you want to delete press any SELECT key area Verify the user number USER 13 DELETED Press COMMAND CMD CMD CMD Add User Profiles Browser US...

Страница 65: ...profile CMD CMD CMD Change User Profiles Browser USER PROFILES ADD DEL CHG PROFILE NO 1 2 4 3 SELECT PROFILE Access the User Menu Press COMMAND until PROFILES displays Press any Select key area SELEC...

Страница 66: ...SELECT DOOR This prompt allows you to search for a door or an output Press the COMMAND key to scroll through the list of doors or output names OUTPUTS ON OFF DOOR ON OFF OUTPUT 127 ON OFF DOOR 128 ON...

Страница 67: ...8 7 9 0 3 4 9 The nine and zero keys Y Z space Pressing the 9 key provides you with Y Z and a space to use between names For example BOB SMITH 0 Pressing the 0 zero key provides you with a dash perio...

Страница 68: ...s if another button is pressed too soon LED Status Operation Depending on the programmed action of a key fob button the Status LED lights to acknowledge a button press or to indicate the armed state o...

Страница 69: ...e you open the door you have 30 seconds to exit and close the door before the zone 2 Soft Shunt expires and triggers an alarm Arming and Disarming an Area System Press Command the keypad displays ARM...

Страница 70: ...e card all areas are disarmed and the keypad displays ALL SYSTEM OFF If the system is disarmed when you present your card once the system validates the card HOME SLEEP AWAY displays You can manually p...

Страница 71: ...he system name zone name zone number message type and the time at which the panel sent the message For alarm messages sent to a cell phone number you have the option to reply with cancel to cancel the...

Страница 72: ...owing command ARM AWAY or ALL To arm all areas depending on your system Arming Partial Areas with Text Commands 1 Text message your system panel with the following command SLEEP To arm the perimeter a...

Страница 73: ...the system will send SYSTEM READY If disarmed with open zones it will send SYSTEM NOT READY followed by any open zones A message of AC POWER TROUBLE will indicate when a power failure occurs If in ala...

Страница 74: ...get an alarm if I come through it later A You will not get an alarm from the door because it is bypassed but if you happen to walk through a motion detector space or other armed door inside the premi...

Страница 75: ...empted a function that is outside of the assigned profile Check the user profile settings INVALID TIME A user code assigned to a specific schedule has entered outside of the valid schedule See Schedul...

Страница 76: ...ser 12 Add User Codes 34 57 Add User Profiles 30 58 Bypass Zones 27 56 Change User Codes 34 57 Change User Profiles 31 59 Delete User Codes 35 58 Delete User Profiles 31 59 Output Group 31 60 Output O...

Страница 77: ...11 K Key Fob Button Layout 8 Keypad 2 Button Panic Keys 5 Common Displays 69 Displays 9 Key Definitions 5 LEDs 4 Multi lingual Display 6 23 Record 44 Select Keys 4 Shortcut Keys 22 Tones 7 Types 3 Use...

Страница 78: ...Alarm b 24 Status 11 Status List 12 System Setup Record 44 System Status 28 System Test 1 28 T TEMP CODE 31 Thinline Keypad 4 5 7 LEDs 3 Panic Keys 5 U User Codes 33 Adding 33 57 Changing 34 57 Deleti...

Страница 79: ......

Страница 80: ...10505 LT 0683CAN 1 03 2010 Digital Monitoring Products Inc...

Отзывы: