DIGITAL LUMENS  |  5

Step One: Install DLA Hardware, cont.

DLA-I Installation

 

2.44 in

   

6.2 cm

 

 

2.44 in

   

6.2 cm

 

1.6 in

 

4.0 cm

 

 

.9 in

 

2.3 cm

 

 

.9 in

 2.3 cm

 

 

 

1.3 to 1.4 in

 3.3 to 3.6 cm 

 

1

.125 in

3.18 mm

Maximum

Gasket

Hex Nut

Fixture

Important Note

The DLA-I is designed to install within a third-party 

fixture housing, with the sensor optic extending externally. 

Be sure to install the gasket and hex nut in the correct 

order, as shown to the right. 

STANDARD INSTALLATION METHOD

a.  Review the DLA-I dimensional drawings, above.
b. Remove and put aside the extra serial number label.
c. Detach the lens assembly by turning it counter-clockwise. 
d. Remove the hex nut.
e. The DLA-I requires a 1 in trade-size knockout (1.3 to 1.4 

in / 3.3 to 3.6 cm hole) for proper mounting and sealing.

f.  Install the DLA-I module inside the fixture housing, with 

the threaded nipple extending outside the fixture housing 

through the opening created in the previous step.

g. Secure the housing using the supplied hex nut. Tighten 

the hex nut.

h. Re-connect the lens assembly, turning it clockwise the 

lens assembly stops rotating.

i.  Make power and data connections (see

 Step Two

 on  

page 6).

j.  Install the third-party fixture as per the manufacturer’s 

instructions.

Содержание DLA-E

Страница 1: ...0V LED drivers DLA sensors communicate wirelessly with the LightRules system to receive commands and send data DLA adapters measure fixture power consumption They also convert the digital commands fro...

Страница 2: ...g tile around the sensor housing and then secure using the 2x supplied Phillips screws Note Place the flat side of the collar against the tile f Replace the bezel g Make power and data connections see...

Страница 3: ...and put aside the extra serial number label b Make power and data connections see Step Two on page 7 c Insert the sensor housing up through the existing cutout in the Philips EvoKit SR fixture d Slide...

Страница 4: ...e d Cut a 5in 7mm or greater hole in the ceiling panel and run the power and data wires through the opening e Make power and data connections see Step Two on page 8 f Secure the housing using suitable...

Страница 5: ...bove b Remove and put aside the extra serial number label c Detach the lens assembly by turning it counter clockwise d Remove the hex nut e The DLA I requires a 1in trade size knockout 1 3 to 1 4 in 3...

Страница 6: ...A I Philips SR Wiring DALI Yellow DALI Yellow White DC Black DC Red L N Black White Philips Xitanium SR LED Driver to LEDs Connect with up to three 3x additional drivers DLA R DLA S or DLA I DALI Wiri...

Страница 7: ...Power and Data Connections cont DLA E Wiring Example Philips EvoKit SR Wiring DLA E DALI Yellow DALI Yellow White DC Black DC Red L N Black White Philips Xitanium SR LED Driver To LEDs Note Use 18 to...

Страница 8: ...ttings which effectively tell the connected light fixture s to remain ON at 100 with no occupancy sensing Active Light Level 100 Inactive Light Level 100 Occupancy Sensor Delay Sensor Inactive Heartbe...

Отзывы: