DLA Sensor

INSTALLATION INSTRUCTIONS

PRODUCT SAFETY

!

  Digital Light Agent

 (DLA) hardware must be installed in accordance with the applicable installation code by a person 

familiar with the construction and operation of the product and the hazards involved.

   To avoid risk of electrical shock, disconnect power before installing, wiring, or servicing DLA hardware.

!

   Do not use fixture or DLA hardware if the housing, sensor optic or wires are damaged.

!

   Do not apply paint, lubricants or other coatings to the DLA housing.

!

   Use a dry cloth to clean the DLA housing and sensor optic.

GETTING STARTED

OVERVIEW

The DLA system transforms fixtures from third-party manufacturers into an intelligent light with high-performance sensors, power 

metering, full-range dimming, and software optimization capabilities. 

There are two categories of DLA components: 

DLA

 

sensors

 and 

DLA

 

adapters

•  DLA sensors measure occupancy and ambient light. They also control connected fixtures through a direct link with Philips SR 

(Sensor Ready) drivers, DALI drivers, or through 0-10 V adapters (for older 0-10 V LED drivers). DLA sensors communicate 

wirelessly with the LightRules system to receive commands and send data. 

•  DLA adapters measure fixture power consumption. They also convert the digital commands from DLA sensors into an analog 

0-10 V signal for use with 0-10 V dimming LED drivers.

Note that this document covers DLA sensors. Please refer to the

 DLA Adapter Installation Instructions

 for adapter setup.

SENSOR TYPES

DLA-R (Recessed Mount)

Use the DLA-R when you want to blend the sensor into an environment by mounting flush to a junction box or 

a ceiling tile.

DLA-E (Philips EvoKit)

The DLA-E is designed to install in the mounting slot of the Philips EvoKit SR retrofit kit. 

DLA-S (Surface Mount)

Featuring an IP65 rating, use the DLA-S in challenging environments. DLA-S mounts to a ceiling surface or 

NEMA 4 or weatherproof junction box. 

DLA-I (Integrated Mount)

The DLA-I mounts directly to into any third-party fixture — the housing mounts inside and the lens assembly 

extends externally. 

HELPFUL HINTS

•  Install the DLA sensor in a manner so as to provide a clear field of view for the lens.
•  Do not mount the DLA sensor within 5 ft (1.5 m) of an air vent.
•  Consult the DLA specification sheets for detail regarding mounting heights and occupancy sensor coverage patterns.

Содержание DLA-E

Страница 1: ...0V LED drivers DLA sensors communicate wirelessly with the LightRules system to receive commands and send data DLA adapters measure fixture power consumption They also convert the digital commands fro...

Страница 2: ...g tile around the sensor housing and then secure using the 2x supplied Phillips screws Note Place the flat side of the collar against the tile f Replace the bezel g Make power and data connections see...

Страница 3: ...and put aside the extra serial number label b Make power and data connections see Step Two on page 7 c Insert the sensor housing up through the existing cutout in the Philips EvoKit SR fixture d Slide...

Страница 4: ...e d Cut a 5in 7mm or greater hole in the ceiling panel and run the power and data wires through the opening e Make power and data connections see Step Two on page 8 f Secure the housing using suitable...

Страница 5: ...bove b Remove and put aside the extra serial number label c Detach the lens assembly by turning it counter clockwise d Remove the hex nut e The DLA I requires a 1in trade size knockout 1 3 to 1 4 in 3...

Страница 6: ...A I Philips SR Wiring DALI Yellow DALI Yellow White DC Black DC Red L N Black White Philips Xitanium SR LED Driver to LEDs Connect with up to three 3x additional drivers DLA R DLA S or DLA I DALI Wiri...

Страница 7: ...Power and Data Connections cont DLA E Wiring Example Philips EvoKit SR Wiring DLA E DALI Yellow DALI Yellow White DC Black DC Red L N Black White Philips Xitanium SR LED Driver To LEDs Note Use 18 to...

Страница 8: ...ttings which effectively tell the connected light fixture s to remain ON at 100 with no occupancy sensing Active Light Level 100 Inactive Light Level 100 Occupancy Sensor Delay Sensor Inactive Heartbe...

Отзывы: