Drive Configuration 

 
 

Before connecting an IDE disk drive to the FireChief, the drive 

must

 be 

configured (jumpered) as a 

Single Master Device. 

Both hard drives must be 

configured (jumpered) as a Master IDE Device.  Certain models of IDE hard 
drives (Western Digital) may specifically require the device to be configured as 
a “Master Device in a Single Drive Configuration” (no Slave device present on 
IDE Channel).

 

 

Diagnostic LED’s 

Each drive rack has a green power LED indicates the drive tray is powered and 
locked into place. 

In addition, each FireWire bridge board on the back of the FireChief has an 
amber LED.  ON indicates the bridge is in Read Only Mode. OFF indicates that 
bridge is in Read/Writeable mode.   

Remember: The upper FireWire bridge is connected to the upper drive bay 
(ReadOnly) and is configured as Read Only.  The lower FireWire bridge is 
connected to the lower drive bay (Read/Write) and is configured as Read/
Writeable. 

 

Drivers 

No device specific drivers are required for the FireChief.  Full driver support is 
provided by the Host operating system and/or FireWire controller.  Normally, the 
necessary drivers will automatically be loaded by the operating system.      
Please refer to your operating system, motherboard, or FireWire controller 
manufacturer for additional driver related information. 

Cables 

Use only high quality FireWire cables.  FireWire 400 to FireWire 800 adapters 
(4 pin to 9 pin and 6 pin to 9 pin) are included with your kit to allow you to hook-
up the FireChief to FireWire 400 connectors. 

 

Drive Bays, Trays and Racks

 

Drive Bays

” are the positions in the chassis provided to facilitate insertion, 

removal, and reconfiguration of hard drives.  A Drive Bay consists of two 
pieces, the Drive Rack and the Drive Tray. 

   

Drive Trays

” are the removable portion of the drive bay which holds the 

hard drive.   

 

Содержание FireChief

Страница 1: ...U S E R G U I D E FireChief I M P O R T A N T R E A D M E F I R S T...

Страница 2: ...is repaired modified or altered unless such repair modification of alteration is authorized in writing by DI or 2 the serial number of the product is defaced or missing Products and corporate names a...

Страница 3: ...amages so the above limitation or exclusion may not apply to you DI reserves the right to modify its warranty statement at any time in its sole discretion DI will be obligated to honor any such warran...

Страница 4: ...FireChief Cabling to PC 2 Drive Configuration 3 Diagnostic LED s 3 Drivers 3 Cables 3 Connecting the FireChief 4 Swapping Drives 5 Disconnecting the FireChief 5 Modifying your FireChief s Read Write C...

Страница 5: ...bay labeled ReadOnly is configured as Read Only and the lower drive bay labeled Read Write is configured as read writeable Power Considerations The FireChief s internal power supply 110 220VAC auto s...

Страница 6: ...is configured as Read Only The lower FireWire bridge is connected to the lower drive bay Read Write and is configured as Read Writeable Drivers No device specific drivers are required for the FireChie...

Страница 7: ...pe Rack Interface Bottom Rear Drive Type Top Front SATA SATA SATA BRIDGE SATA IDE Connecting the FireChief Make sure the FireChief is powered off prior to connecting a hard drive 1 Connect the Hard Dr...

Страница 8: ...lock into place 6 Reconnect FireChief to host computer Power on FireChief and reconnect the FireWire cable to the host computer s FireWire controller 7 Power on the FireChief Disconnecting the FireChi...

Страница 9: ...at type of code page device characteristics is reported to the calling process when a device query is made If the switch is OFF the code page is reported appropriately to indicate that the device is w...

Страница 10: ...correctly may not function properly with this device These drives are typically quite old and always less then 8 GB in size and are usually less than 2 GB in size Using a FireWire 800 Device with Mic...

Страница 11: ...FireChief User Manual 13 Firmware updates If there is a need to update firmware please consult Digital Intelligence web site support pages http www digitalintelligence com support php...

Страница 12: ..._____________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ ________________...

Страница 13: ...2007 Digital Intelligence Inc All rights reserved w w w d i g i t a l i n t e l l i g e n c e c o m Digital Intelligence Inc 17165 W Glendale Dr New Berlin WI 53151 P 262 782 3332 F 262 782 3331...

Отзывы: