1.3.4 Configuration Display
The configuration display shows the system configuration and the error messages
that were detected while the most recent power-up tests, diagnostic tests, and
utilities were running. If you add expansion boxes to the system and do not run
the power-up tests or appropriate diagnostic test or utility, the configuration
display does not recognize the reconfiguration. Enter the following command to
see the configuration display:
>>> SHOW CONFIG
If the system does not detect any errors in the most recent power-up tests
or diagnostic utilities, it responds with a configuration display similar to the
following:
KA55-A or KA51-A or KA56-A V2.6, VMB 2.15
08-00-2B-33-CF-C9
80MB
!
"
#
TstNbr
DevNam
Info
------
--------
--------------------------
0
CPU_BD
OK
A8
MEM
OK
E4
DZ
OK
E0
SCSI
OK
3-RZ24L
6-Adapter
7-RRD43
$
5F
NI
OK
F0
SCSI_B
OK
0-RZ23L
6-Adapter
0
QBUS
OK
E8
COMM
OK
DSW41/42 2 CHANNEL V4.10-7b
EC
ASYNC
OK
DHW41/2 V1.6
!
Test Utility Number Column
"
Device Mnemonic Column
#
Device Status Column
$
SCSI IDs and SCSI Device Names
The test numbers listed identify the normal test or script number to run to verify
the device listed. There are additional tests and utilities for some devices. Test 0
calls the power-up script.
1–22 Troubleshooting and Diagnosing Problems