3–7
Problem Solving
Table 3–2 (Cont.): Isolating Network Connection Faults
Symptom
Probable
Cause
Corrective Action
System is on.
Controller LED
is steady red.
Network
problem.
Disconnect the controller cable.
If the LED flashes green, the con-
troller is functional.
Reconnect the cable, try a new
cable, or connect to a different
concentrator port.
Controller
problem.
Disconnect the controller cable.
If the LED remains red, the
controller might be at fault.
Reboot the system and watch the
self-test.
If the problem persists, contact
your Digital sales representative.
Controller LED
continues to
flash green and
does not
change to solid
green when the
cable is con-
nected.
Driver not
installed
correctly.
If the software driver is installed
correctly, and the controller is
configured properly, then refer to
the file
README.TXT
in
subdirectory
A:\DIAG
of diskette
1 for information on running the
INSTVER network diagnostics
(also refer to Section 3.6).
Faulty controller
cable or
connection.
Verify the integrity of the controller
cable. Replace if defective.
Faulty FDDI
concentrator.
Verify the integrity of the
concentrator. Replace if defective.
Содержание DEC FDDIcontroller/EISA