External Interfaces

• This PL unit’s serial port is not isolated. 

When the host (PLC) unit is also not 
isolated, and to reduce the risk of dam-
aging the RS-232C/RS-422/RS-485 
circuit, be sure to connect pin #5 SG 
(Signal Ground) terminal.

• Never connect NC to COM1.

• Connect FG to shell.

„

Serial Interface 
(COM1, COM2, COM3, COM4)

‹

COM1, COM2, COM3, COM4

‹

COM1

*3 To change the communication method, set 

the dip switch located on the circuit board in 
the PL unit to the desired position.
For details, see [Internal Switches].

Interfit Bracket #4-40 UNC

Pin #

RS-232C

Signal Name

Meaning

1

CD

Carrier Detect

2

RD(RXD)

Receive Data

3

SD(TXD)

Send Data

4

ER(DTR)

Data Terminal Ready

5

SG

Signal Ground

6

DR(DSR)

Data Set Ready 

7

RS(RTS)

Request to Send

8

CS(CTS)

Clear to Send

9

CI(RI)/+5V

Called status display/
+5V Output 0.5A

*1

 

*2

*1 Only COM1 and COM2 are available for 

switching to +5 V. COM3 and COM4 are used 
exclusively for CI (RI).

*2 Slide switch on the circuit board in the PL unit 

switches between CI (RI) and +5 V. For 
details, see [Internal Switches].

Shell FG

Frame Ground
(Common with SG)

Pin #

RS-422 

*3

Signal Name

Meaning

1

RDA

Receive Data A(+)

2

RDB

Receive Data B(-)

3

SDA

Send Data A(+)

4

ERA

Data Terminal Ready 
A(+)

5

SG

Signal Ground

6

CSB

Clear to Send B(-)

7

SDB

Send Data B(-)

8

CSA

Clear to Send A(+)

9

ERB

Data Terminal Ready 
B(-)

Shell FG

Frame Ground
(Common with SG)

Pin #

RS-485

*3

Signal Name

Meaning

1

DATA  +

Send/Receive Data 
(+)

2

DATA  -

Send/Receive Data 
(-)

3

NC

No Connection

4

NC

No Connection

5

SG

Signal Ground

6

NC

No Connection

7

NC

No Connection

8

NC

No Connection

9

NC

No Connection

Shell FG

Frame Ground
(Common with SG)

Содержание APL3700-TA

Страница 1: ...ssing please contact your local PL distributor immediately When you order a PL unit built to your specifications that PL package should include each optional item s Installation Guide Please use that guide to check the contents of each optional item s package About the Manual For the detailed information on PL series refer to the following manuals PL3000 Series Hardware Manual PL3000 Series Refere...

Страница 2: ...s Soft OFF State is different from Windows System Standby E USB interface 1 port USB2 0 compatible Type A connector is used A B C E D Front LED Indicates Green lit Normal operation power is on Green blinking Soft OFF state Orange lit System monitor error RAS error Touch Panel Self Test Error Orange Red blinking Backlight burnout is detected Not lit Power is OFF LED Indicates Green lit When HDD or ...

Страница 3: ...tor is used M Speaker output interface SPK Mini pin jack connector N HDD status lamp HDD0 HDD1 For HDD0 and for HDD1 from left to right O Serial interface COM1 D Sub 9 pin plug type RS 232C RS 422 RS 485 Changeover CI RI 5V Changeover P Serial interface COM2 D Sub 9 pin plug type RS 232C CI RI 5V Changeover Q Serial interface COM3 COM4 D Sub 9 pin plug type RS 232C COM3 and then COM4 from the top ...

Страница 4: ...oltage Drop 5ms or less 1 cycle or less Voltage drop interval must be 1s or more 1 1 When the total of the expansion slot power and the external load power exceeds 25W the length of the allowable voltage drop will be 20ms or less For details refer to the chart below Power Consumption 145W or less 145VA or less In Rush Current 40A or less Voltage Endurance AC1000V 10mA for 1 minute between charging...

Страница 5: ...et the Windows 2000 s Control panel Power Management option Turn off hard disks selection or the Windows XP s Control panel Performance and Maintenance Power Management option Turn off hard disks selection to turn the hard disk off when the unit is not being operated A setting of 5 minutes is recommended Do not vibrate the hard disk continuously at the same frequency Doing so may cause the hard di...

Страница 6: ... Factory setting 2 Implements the logical inversion operation for RAS output Normal Close Normal Open OFF RAS output is a CLOSE state when the SW and the system is ON When the SW is OFF it is the opposite The RAS Output keeps Normal OPEN when the Soft OFF state occurs or the power turns OFF 3 Sets up an enabled disabled state for the front USB port execution control function 1 1 The Setting up an ...

Страница 7: ...ver is controlled with the RS RTS signal Set switch number 4 to ON 5 Switches the SD TXD termination resistance ON OFF Inserts termination resistance of 220Ω between SDA and SDB No termination OFF ON ON OFF 3 3 If you use the termination resistance base your settings on the connection specifications 6 Switches the RD RXD termination resistance ON OFF Inserts termination resistance of 220Ω between ...

Страница 8: ...ncellation function of two point touch on the touch panel 1 1 When two points are pushed it is considered that middle point between the two points is touched according to the nature of the analog resistive touch panel When the switch etc is set on the middle point it will be enabled and may operate To prevent such a switch from malfunction in case of pushing two points turn ON the SW No 4 in advan...

Страница 9: ... Ready 7 RS RTS Request to Send 8 CS CTS Clear to Send 9 CI RI 5V Called status display 5V Output 0 5A 1 2 1 Only COM1 and COM2 are available for switching to 5 V COM3 and COM4 are used exclusively for CI RI 2 Slide switch on the circuit board in the PL unit switches between CI RI and 5 V For details see Internal Switches Shell FG Frame Ground Common with SG Pin RS 422 3 Signal Name Meaning 1 RDA ...

Страница 10: ...he panel of a cabinet or enclosure Surrounding air tem perature indicates both the panel face and cabinet or enclosure s internal temperature Be sure that heat from surrounding equip ment does not cause the PL to exceed its standard operating temperature 2 PL Installation 1 Create a Panel Cut following the dimen sions in the following table Also deter mine the panel thickness according to the pane...

Страница 11: ...uired to tighten these screws is 0 8 N m Installation uninstallation of the front module and the control box To avoid an electric shock prior to instal lation uninstallation of the front module and the control box confirm that the PL unit s power supply is completely turned OFF via a breaker or similar unit 1 Uninstalling the front module and the control box 1 Unscrew the two attachment screws to ...

Страница 12: ...witch to its power cord When the FG terminal is connected be sure the wire is grounded 1 Wiring the AC type power supply cable When the FG terminal is connected be sure the wire is grounded Not grounding the PL unit will result in excessive noise Use your country s applicable standard for grounding Power Cord Specifications Use copper conductors only Wiring When connecting the power code use the f...

Страница 13: ...licable standard for grounding Power Cord Specifications Use copper conductors only Power Connector Plug Specifications Accompanying power supply connector is CA5 DCCNL 01 of Pro face or GMVSTBW2 5 3 STF 7 62 of Phoenix Contact When connecting the power code use the following items when performing wiring Items are made by Phoenix Contact Connecting the PL Power Cord 1 Confirm that the power is not...

Страница 14: ...t of noise connect a noise reducing transformer The temperature rating of field installed conductors 75 C only Use voltage and noise reducing trans formers with capacities exceeding Power Consumption value Branch Circuit Protective device shall be use for rating 20A for DC24V input device Connect a surge absorber to handle power surges Be sure to ground the surge absorber E1 separately from the PL...

Страница 15: ...ows you to securely clamp the USB cable in the cable clamp The USB cable clamp is not compatible with the USB connector on the front face 2 Fix the USB holder with two screws The torque required to tighten these screws is 0 5 to 0 6 N m 3 As the figure shows pass the USB Cable Clamp s band around the depressed sur face of the holder twist the USB Cable Clamp s band around the USB cable pull the ba...

Страница 16: ...space around the rear face of the PL unit The temperature must be checked on the final product in which the PL unit is installed For use on a flat surface of a Type 1 Enclo sure CE Marking APL3700 TA unit is CE marked product that conforms to EMC directives and Low Voltage Directives EN55011 Class A EN61000 6 2 and EN60950 1 APL3700 TD unit is CE marked product that conforms to EMC directives EN55...

Отзывы: