4
• When attaching peripheral units to the PL, be sure the PL’s power cord is
disconnected from the main power supply.
General Specifications
Electrical Specifications
Name
Description
T Fan cover
System fan inside
U System fan
A fan for cooling the PL unit.
V Power connector
—
W Power switch
AC type only.
Power
Supply
DC type
AC type
Input Voltage
DC24V
AC100 to 240V
Rated Voltage
DC19.2 to 28.8V
AC85 to 264V
Rated Frequency
—
50/60Hz
Allowable Frequency
Range
—
47 to 63Hz
Allowable Voltage
Drop
5ms or less
1 cycle or less (Voltage drop
interval must be 1s or more.)
*1
*1 When the total of the expansion slot power and the external load power exceeds 25W, the length of
the allowable voltage drop will be 20ms or less. For details, refer to the chart below.
Power Consumption
145W or less
145VA or less
In-Rush Current
40A or less
Voltage Endurance
AC1000V 10mA for 1 minute
(between charging and FG terminals)
AC1500V 20mA for 1 minute
(between charging and FG terminals)
Insulation Resistance
DC500V 10M
Ω
(min.)
(between charging and FG terminals)
DC500V 10M
Ω
(min.)
(between charging and FG terminals)
Bottom
(2 slot type)
Top
(2 slot type)
T
V
W
U
J
Allowable Range
(ms)
20
15
25
40 (W)
0