Features, Applications, and 

Specifications 

 

 

Features: 

 

• Discrete solid state I/O (input - output) construction

 

• Microprocessor controlled timing with accuracy to 0.0001 of a second 
• Retains all numbers even when power is disconnected from the unit 
• Large display for easy reading of times 
• Low voltage warning and full status indication 
• Illuminated liquid crystal display for both day and night use 
• Dust & splash proof display lens & key pad with detent (positive feel) 
• 1 or 2 pushbutton, bumb up or down, and recovery 
• Easy and fast selection or entry of all information even with gloves 
• Self test mode on all display functions 
• Programmable back-light intensity control 
• Very high Transbrake current output (20 Amps) 
• Instant timing cycle reset 

 

 

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••• 

 

 

Applications: 

 

• Controls Transbrake Solenoids 

• Controls 2, 3 and 4-Stage Timers 
• Controls 2-Steps 
 

 

 

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••  

 

 

Specifications: 

 

 

 

Input Voltage Range:

  

10 to 16 Volts DC 

 

Dial-In Time Range:   

00.00 to 99.99 seconds in .01 increments 

 

Delay Time Range:   

0.000 to 9.999 seconds in .001 increments 

 

Flinch Time Range:

 

 0.000 to 0.999 seconds in .001 increments 

 

Push Button Input Current Draw:  

0.1 Amps. at 12 Volts

 

• 

Transbrake Output Current:

  20 Amps.  

 

Operating Temperature Range:

 

 

0 to 150 degrees F 

 

 

 

 

 

 
 
 

Содержание 1020-SCR

Страница 1: ...ORATED harmless from defend and indemnify DIGITAL DELAY INC against damages claims and expenses arising out of subsequent sales of or use of DIGITAL DELAY INC products or products containing component...

Страница 2: ...entry of information into the unit while a single illuminated multi segment liquid crystal display is used to display all relative information Contents Warranty and Disclaimer Page 1 Features Applicat...

Страница 3: ...nd recovery Easy and fast selection or entry of all information even with gloves Self test mode on all display functions Programmable back light intensity control Very high Transbrake current output 2...

Страница 4: ...4...

Страница 5: ...utton 1 Terminal In single Push Button Mode the push button connected to Button 1 terminal is used to control the primary delay and the secondary delay in sequence In dual Push Button Mode the push bu...

Страница 6: ...e display will flash when voltage to the unit is below the recommended minimum of 11 5 Volts Transbrake Colons When the transbrake is engaged the colon will turn on When the delay timer starts countin...

Страница 7: ...he function key is used with the numerical keys for entering new times or modes For example to enter a new Delay 1 Time first press the 3 key on the keypad to bring up the current stored Delay 1 Time...

Страница 8: ...o enter the new three digit time into memory leading zeros must be entered As the numbers are entered they will appear on the display indicating the number was accepted and stored into memory At any t...

Страница 9: ...on means uump up no arrow means tap down After selecting the desired Tap Up or Down mode enter the new number 1 9 for the programmable time NOTE Both How Late and Tap information are stored in memory...