Wiring and Testing the Unit

 

 

 

 

To test the four push button inputs and the four yellow L.E.D.s, disconnect all wires going to the 

four push button inputs.  Next take a piece of wire, connect one end to g

round, 

then touch the other end 

to each of the four push button inputs. As the inputs are touched by the wire the corresponding yellow 
L.E.D. should light. 
 The 

Crossover Plus with 4-Stage Timer 

has a built-in test mode for the displays and the red 

L.E.D.s.  The function key F is held down while the power is being turned on, the unit will go into a test 
mode and stay in the test mode until the F key is released.  

 

 

While in test mode:  
1) 

The displays will start at “0000” and count up, adding “1111” to the 

 

number shown on both displays every half second.   

2) 

While the numbers are counting up, the decimal points will switch 

 

back and forth between “00.00” and “0.000” while both the arrows 

 

and colons will flash.   

3) 

The six red L.E.D.s will flash back and forth every half second. 

4) 

Both the transbrake and throttle outputs will be off during the test.  

 
 
 
 
 
 

 

 

 

 

 

Содержание 1014-SCR

Страница 1: ...PORATED harmless from defend and indemnify DIGITAL DELAY INC against damages claims and expenses arising out of subsequent sales of or use of DIGITAL DELAY INC products or products containing components manufactured by DIGITAL DELAY INC and based upon personal injuries deaths property damage lost profits and other matters which BUYER its employees or sub contractors are or may be to any extent lia...

Страница 2: ...r fast and precise entry of information into the unit while two illuminated multi segment liquid crystal displays are used to display all relative information Contents Warranty and Disclaimer Page 1 Features Applications and Specifications Page 3 Quick Reference Diagram Page 4 The Terminal Strip Page 5 The Displays Page 6 The Keypad Page 7 Setting Dial Ins Delay and Stage Times Page 8 Setting Thro...

Страница 3: ...ation even with gloves Self test mode on all displays functions Both Transbrake and Throttle control outputs Very high current output 20 Amps Instant timing cycle reset Applications Controls Transbrake Solenoids Controls Starting Line Throttle Stops Controls Throttle Stops Controls Nitrous Solenoids Controls 2 Steps Specifications Input Voltage Range 10 to 16 volts DC Dial In Time Range 00 00 to 9...

Страница 4: ...4 ...

Страница 5: ...he bypass terminal can also be used as an override if you flinch in single Push Button Mode at the starting line Simply press and hold the bypass push button and go off your bottom bulb avoiding the red light due to flinching Button 1 Terminal In single Push Button Mode the push button connected to Button 1 terminal is used to control the primary delay and the secondary delay in sequence In dual P...

Страница 6: ...isplay A would be showing Your Time and Display B would be showing Their Time Other special functions of the displays are Low voltage indication The numbers on both displays will flash indicating the voltage to the unit is below the recommended 11 5 Volts Transbrake Colons When the transbrake is engaged both colons will turn on and when the delay timer starts counting down both colons will flash S...

Страница 7: ...o erase the last digit This can be repeated as many times as necessary until the display is blank Function Keys C D and E The function keys C D and E are used to select what information is shown on the displays The corresponding six red L E D s two for each key indicate when lit what information is being displayed For example if the Dial Ins are wanted and the First and Second Stage Times are bein...

Страница 8: ... A or B for the display again will erase the last digit entered This can be repeated as many times as necessary until the display is blank Setting Delay Times To set a new delay time into either Delay 1 or 2 press the C key until the delay times are displayed Then follow the same procedure for entering a new number as instructed in setting new Dial In times Setting Stage Times To set a new stage t...

Страница 9: ...etting and Displaying the Bump Information To display the Bump information press the D key until the Bump information is shown on Display A The left most digit shows the programmable time 1 to 9 hundredths of a second to be added to or subtracted from the delay time every time the Bump push button is pressed To change the number press the A key and enter the new number 1 9 To switch between the bu...

Страница 10: ...e for the displays and the red L E D s The function key F is held down while the power is being turned on the unit will go into a test mode and stay in the test mode until the F key is released While in test mode 1 The displays will start at 0000 and count up adding 1111 to the number shown on both displays every half second 2 While the numbers are counting up the decimal points will switch back a...

Страница 11: ...on the throttle stop will stay on Stage 3 represents when the throttle stop will turn on the second time during the run Stage 4 represents the amount of time or duration the throttle stays on the second time Both Stage 1 and Stage 3 start counting from the release of the transbrake Stage 2 starts counting after the amount of time set in Stage 1 is completed Stage 4 starts counting after the amount...

Отзывы: