Installation and configuration
Page 34
Note:
Any unused ports should be terminated by a 120 Ohm resistor across
RX A and RX B signals. COMMON signals should be grounded.
All sensor ports can be configured via the Interface settings menu which can
be found under the
‘Home’ > ‘System settings’ > ‘Interfaces’
menu option.
The Interface settings menu also includes the ability to disable the requirement
for external GNSS sensors to provide a DTM (Datum) sentence.
3.4.6
Alarm connections
The AIS transceiver also provides connections to the alarm relay contacts.
The alarm relay connections are described in Table 3.
Table 3 Alarm relay connections
Alarm connection
Function
Contact rating
COM
Alarm relay common
connection
2A at 220VDC or 60W
maximum
NC
Alarm relay normally
closed connection
I
f an external GNSS device which does not provide a DTM
sentence is connected to the AIS transceiver and the AIS
transceiver is configured to require DTM sentences, the
external GNSS data will not be accepted by the AIS
transceiver. If no DTM sentence is required the WGS84
datum will be used as a coordinate origin and the
external GNSS device must be configured to output
position using this datum.
!
Содержание CLA2000
Страница 1: ...CLA2000 CLASS A AIS TRANSPONDER Installation and Operation Manual...
Страница 10: ...Table of contents Page 8...
Страница 18: ...Notices Page 16...
Страница 20: ...Introduction Page 18...
Страница 26: ...Installation and configuration Page 24 Figure 5 Desk mounting the AIS transceiver...
Страница 42: ...Installation and configuration Page 40...
Страница 86: ...Technical information Page 84...
Страница 98: ...Technical specification Page 96...
Страница 102: ...Installation record Page 100...
Страница 103: ......
Страница 104: ...support digitaldeepsea com 202 0919 1...