The 1.75” (4.45cm) high chassis fills a uniform one rack unit (RU) in height.  

 

IMPORTANT NOTE:  
There can be a tremendous amount of weight applied to the face plate when the unit 
is fully cabled. Users are encouraged to provide a means of cable management at 
the rear of the rack to avoid excessive cable weight force on the unit.  

 

Because the device consumes very little power (<25 Watts) there are no venting 
restrictions. This allows stacking devices without the need or provision for spacing in 
between units. 

 

4  Test Cable Wiring 

 
Much like the internal circuitry, the R232’s input and output connectors are a 
precision component and must be treated as such. Therefore, i

t is critical that NO 

EXCESSIVE FORCE BE APPLIED TO THE INPUT/OUTPUT CONNECTORS.

  

 

 

CRITICAL NOTE:  

 

Do not exceed 10 in/lbs. (1.12 N/m) of torque on any F-connector! 

 

 

OVER TORQUING THE CONNECTORS MAY CAUSE IRREPARABLE INTERNAL 

DAMAGE AND IS NOT COVERED UNDER WARRANTY! 

 
Please be aware that generally available cable F-connector torque wrenches are 
typically set for 20 in/lbs. used for outdoor connectors. Moreover, they are 
notoriously unreliable in delivering proper torque for these precision components and 
therefore it is strongly advised not to use them in this application. 
 
 

4.1  F-Connection Rule of Thumb:  

Finger tighten the cable to the F-connector, then tighten no more than a quarter (1/4) 
turn if at all. This should provide a secure connection without applying a damaging 
amount of torque to the connector.  

 

 

Содержание R232

Страница 1: ...igital Alert Systems Inc Information herein is considered accurate at the time of publication We constantly strive to improve our products and services therefore some specifications are subject to cha...

Страница 2: ...8 Table of Contents 1 PRODUCT OVERVIEW 3 1 1 INTRODUCTION 3 2 POWER CONNECTIONS 4 2 1 1 R232 POWER CONNECTIONS AC 4 2 1 2 R232 48VDC POWER CONNECTIONS DC 5 3 MOUNTING 6 4 TEST CABLE WIRING 7 4 1 F CO...

Страница 3: ...es of this document the term R232 will be used synonymously unless there is a need to differentiate the models The R232 front panel features a row of LED indicators to indicate the presence of power a...

Страница 4: ...yle Although the inputs differ the connection points and cable arrangements are the same Both models feature the patented Pocket Power Supply which is a unique opening on the right side of the chassis...

Страница 5: ...ted to the chassis as shown in Figure 6 while the mating connector can be easily removed to facilitate installation of the power cabling IMPORTANT NOTE CLOSELY OBSERVE THE CONNECTION POLARITY TO AVOID...

Страница 6: ...th DC power cabling installed and properly configured Once power connections are made the unit is ready for mounting 3 Mounting The R232 is designed to be mounted in a standard Electronic Industries A...

Страница 7: ...on component and must be treated as such Therefore it is critical that NO EXCESSIVE FORCE BE APPLIED TO THE INPUT OUTPUT CONNECTORS CRITICAL NOTE Do not exceed 10 in lbs 1 12 N m of torque on any F co...

Страница 8: ...net 10 100 BASE T Ethernet IEEE 802 3 Network Connection RJ 45 connectors suited for wiring CAT 5 or above Indicators Green link data indicators Chassis 19 0 W x 12 75 D x 1 75 H 48 3 cm W x 32 385 cm...

Отзывы: