Input Impedance:

 

Input impedance may be either 10 k

 or 600 

. The 

J2

 jumper determines the input impedance of the 

3185E. Install a jumper at position 

J2 

to terminate the audio input in 600 

. Consult FIGURE 3 for the 

J2

 

jumper location. 

Input Balanced/Unbalanced:

 

The input may be selected to be balanced or unbalanced. The 

J1

 jumper determines whether the input 

is balanced or unbalanced. Removing the short from 

J1

 will make the input balanced. Consult FIGURE 3 

for the 

J1

 jumper location. 

5 Minute Restoral

The  3185E  may  be  selected  to  restore  the  output  status  for  a  power  interruption  of  less  than  five 

minutes.  The  3185E  is  factory  set  to  enable  this  restoral.  The 

J7

  jumper  is  open.  To  disable  the  five 

minute restoral install a jumper on 

J7

. Consult FIGURE 3 for 

J7

 location. 

Momentary Output for ON & OFF:

 

This  setting  provides  a  momentary  output  relay  activation  for  both  the  ON  sequence  and  the  OFF 

sequence. Momentary duration is 1 second. To enable this feature, install both J3 and J4. 

Output Relay:

 

The output relay on the 3185E may be set in three different modes of operation; 

latching, momentary

 or 

alternate action

 (toggling). The 3185E is factory set to latching.  

Being  set  at 

latching

  means  the  output  relay  will  energize  when  the  pre-programmed  'ON'  code  is 

rece

ived  or  the  ‘Set’  input  is  momentarily  connected  to  circuit  common.  The  output  relay  will  remain 

energized until the preprogrammed 'OFF' code is received or 

the ‘Reset’ input is momentarily connected 

to circuit common. 

When the output relay is programmed to operate in the 

momentary

 mode, it will energize for the duration 

that  the  last  valid  digit  is  present.  In  the  momentary  mode  the  3185E  will  not  respond  to  its  pre-
programmed 'OFF' code. 

Alternate  action

  programs  the  relay  for  latching  (toggling)  relay  output.  In  this  mode  the  output  relay 

energizes and de-energizes with the same pre-programmed 'ON' code sequence. 

10 Second Pulse:

 

If both ‘Set’ and ‘Reset’ are low and the relay mode is ‘momentary’, then when a valid ‘ON’ sequence of 

digits is received, the 

relay is turned on for 10 seconds then ‘OFF’ – even if the last tone is still present.  

The  decoder  will  ignore all  tones and ‘Set’ and ‘Reset’ activities  during the 10-second period.  Applies 
only to firmware version 80154-1.10 and later. 

 
 
 
 
 
 
 

Содержание 637

Страница 1: ...ly closed NC as desired connections on the terminal block 3 The connections on the terminal block for RELAY 1 and RELAY 2 are separate contacts but are part of the same relay 4 The SET and RESET conne...

Страница 2: ...ress implied or statutory including without limitation the implied warranties of merchantability and fitness and including but without being limited to any obligation of Digital Alert Systems with res...

Страница 3: ...Digital Alert Systems 100 Housel Ave Lyndonville NY 14098 phone 585 765 2254 fax 585 765 9330 digitalalertsystems com Printed in USA Copyright Digital Alert Systems Inc Specifications subject to chang...

Страница 4: ...onnection 9 Power Supply Input 9 CUSTOMER OPTIONS 10 FIGURE 3 Jumper Locations 11 Input Impedance 12 Input Balanced Unbalanced 12 5 Minute Restoral 12 Momentary Output for ON and OFF 12 Output Relay 1...

Страница 5: ...features include Dual Form C Relay Output Selectable Input Impedance Selectable Balanced Unbalanced Input Adjustable Input Signal Range Restoral of Output Status if Power Interruption is Less Than 5 M...

Страница 6: ...dBm 155mV to 489 mV Optional 10 dBm Adjustable Digit Validation Time 40 ms Minimum Inter Digit Time Minimum 40 ms Maximum 3 Seconds Maximum Digits Per Second No Twist 13 6 dB 12 Relay Output DPDT 30...

Страница 7: ...Common terminal for relay output referenced to pins 9 and 10 2 Circuit common ground 3 Circuit common ground 5 Audio input low audio input circuit common if unbalanced 6 Audio input high 8 12 Volt D C...

Страница 8: ...8 FIGURE 1 Edge Connector Switch and Indicator Locations and Modifications for 4 digit ON OFF Operation FIGURE 2 Block Diagram...

Страница 9: ...5E to reset This input is level sensitive and requires a minimum pulse of 20 msec to circuit common to reset the card The Reset input dominates over all other functions NOTE The 3185E will ignore all...

Страница 10: ...ng Input Impedance 10 k Input Unbalanced 5 Minute Restoral Enabled Momentary Output for ON and OFF Disabled Output Relay Latching 4 Digit Decode Sequence for Fourth Digit ON for Fourth Digit OFF Jumpe...

Страница 11: ...UTPUT FOR BOTH ON OFF X X X JUMPER INSTALLED O JUMPER REMOVED R12 INPUT SIGNAL LEVEL RANGE ADJUSTMENT JUMPER OPEN SHORTED INPUT IMPEDANCE J2 10k 600 INPUT TERMINATION J1 BALANCED UNBALANCED 5 MINUTE R...

Страница 12: ...the 3185E may be set in three different modes of operation latching momentary or alternate action toggling The 3185E is factory set to latching Being set at latching means the output relay will energ...

Страница 13: ...s to decode is determined by jumpers J6 and J5 Consult FIGURE 3 page 7 for the location of J6 and J5 The programming of jumpers for the number of digits to decode is shown below NUMBER OF DIGITS JUMPE...

Страница 14: ...This LED indicator will continue to illuminate until a valid DTMF digit is detected or DC power is removed from the board The Valid Sequence LED CR15 will illuminate upon the decoding of a correct DT...

Страница 15: ...nce for ON SWITCH 3 second digit for code sequence for OFF If the 3185E is programmed for momentary relay output or alternating relay action SWITCH 3 is not used for programming Operating With a 1 Dig...

Страница 16: ...mplied warranties of merchantability and fitness and including but without being limited to any obligation of Digital Alert Systems with respect to incidental or consequential damages or damages for l...

Отзывы: