Digital Acoustics INT-IP-2GANG Скачать руководство пользователя страница 3

Digital Acoustics INT-IP-2Gang 

Installation and SIP Configuration 

Page 3 of 3 

 

Select the 

SIP Settings

 tab

 

  Press the 

Apply Defaults

 button on the bottom right to copy in the 

default SIP information that was previously setup 

  Enter the 

SIP Extension

SIP Password

 (also known as the 

Secret

that have been setup on the SIP based phone system for this IP7 
device 

  In the 

SIP Authentication

 (also known as the 

SIP Authorization 

Name

), enter the User that has been associated with this extension in 

the SIP based phone system.  If no User has been setup, use the 
same value as the SIP Extension 

  Check the 

Full Duplex

 option to enable full duplex operation or leave 

it blank for of half duplex 

o

 

In a half-duplex phone call, one party has their microphone active 
while the other party has their speaker active. By default, when a 
call is initiated, the INT-IP-2Gang starts with the speaker active 
and the phone operator starts their microphone active.  The 
phone operator can toggle the modes by pressing 0 on the 
phone’s keypad. In half duplex mode, the INT-IP-2Gang volume 
will always be louder, and the microphone gain will always be 
higher 

o

 

In full duplex mode, both parties have their speaker and 
microphone active at the same time. In full duplex mode, the INT-
IP-2Gang volume will always be softer, and the microphone gain 
will always be lower.  This is due to the algorithms used by the IP7 
for echo cancellation 

 

  Check the 

Outdial Extension

 and enter the number to be automatically dialed when the integrated Call button is 

pressed 

  If the integrated relay will be used to open a door during a call, specify a 1 

– 4 digit code in the 

Door Open Code

 to be 

entered on the phone’s keypad.  If the specified code has multiple digits, the phone operator will need to enter a # after 
the code (using this example, phone operator would need to enter the digits 65# during the call to activate the relay).  If 
only a single digit is specified, the phone operator only needs to enter that digit. 

 
 

Select the 

Advanced Settings 

tab

 

  Click the 

Set 

button next to 

Audio Profile

 and

 s

elect the 

INT-IP-

2Gang

 audio profile if using full duplex.  Otherwise select the 

Half 

Duplex

 audio profile 

  Click the 

Save Settings

 button.  The endpoint will reboot with the 

changes and register with the SIP Server within 30 seconds. The red 
Call button LED on the panel will blink rapidly for 30 seconds and 
then turn solid  

  There are 7 volume steps that will vary based on whether full or half 

duplex has been configured.  Volume can be adjusted when a SIP 
call is in progress by pressing: 

o

  #00 

– Set volume down one level 

o

  #01 

– Set volume level to 1 

o

  #02 

– Set volume level to 2 

o

  #03 

– Set volume level to 3 

o

  #04 

– Set volume level to 4 

o

  #05 

– Set volume level to 5 

o

  #06 

– Set volume level to 6 

o

  #07 

– Set volume level to 7 

o

  #08 

– Set volume up one level 

  For Full Duplex, the volume level should be set to 4 or 5 for best results 

 

 

IP7 and Digital Acoustics® are trademarks of Digital Acoustics LLC. 

Other trademarks are the property of their respective owners. 

All Rights Reserved ©2019 