background image

Page 1 of 3 

 

 

INT-IP-2GANG 

SIP Getting Started Guide 

 

Introduction 

The INT-IP-2GANG is a PoE powered (802.3af) IP Intercom Call Station that can be configured as a SIP extension 
for use with a SIP based phone system. The unit fits in a standard 2-gang electrical box with plaster ring that has a 
minimum depth of 2” and is suitable for installation indoors or outdoors in damp locations.  It includes:

 

 

Integrated Microphone - water resistant

 

 

Integrated Speaker 

– waterproof cone

 

 

Security screens protect Microphone and Speaker 

 

Integrated vandal resistant Call button with LED 

 

Integrated Relay for door/gate activation 

 

PoE (802.3af)  

 

Includes four stainless steel security screws (T10) 

 

User configurable Full or Half duplex operation  

 

12 Gauge Stainless Steel Call Station panel  

 

The INT-IP-2GANG is configured using the Digital Acoustics 

eSIP Configuration

 utility. This 

Getting Started Guide

 

covers basic hardware installation and software configuration of the INT-IP-2GANG. 
 

Installation 

The INT-IP-2Gang can be flush mounted into a standard 2-gang electrical box or surface mounted in an optional 
surface mount box.  For outdoor installations, mount under an eave or use a hooded surface mount box.  Please note, 
the INT-IP-2Gang can be configured before being installed in the 2-gang box. 

 

Connect RJ-45 (B4) to a PoE (802.3af) network 
switch or injector.  The INT-IP-2GANG will power up 
within 5 seconds and request 7.0 watts from the 
Power Source Equipment  

 

If the relay will be used to activate an electronic door 
strike, connect the COM (B2) and either the NO (B1) 
or NC (B3) to the door strike 

 

The green 

Link

 LED (B5) will turn solid.  The yellow 

Ready

 LED (B6) and the Call button LED will flash 

4x per second 

 

Record the 

ID#

 from the label on back of the INT-IP-

2GANG for use during software configuration. 

 

Optionally, label the panel with one of the extra 

ID# 

labels  

 

Install the Call Station in the 2-gang electrical box with the call button in the upper left-hand corner so the 
RJ-45 connector faces down  

 

Fasten using the four security screws (T10)  

 

Use a high-quality silicone sealant between the top and sides of the unit and the surface it is mounted to 

 

The Call Station LED will continue to flash until configuration is complete 

 

Please refer to the 

INT-IP-2GANG_ReferenceManual

 available at 

https://www.digitalacoustics.com/support/ip7-hardware-talkmaster-software-manuals/ for additional 
information on installation 

Отзывы: