DigiSpider CFM Series Скачать руководство пользователя страница 35

 

 
 

30

 

Copyright © 2009 Digispider. All rights reserved. 

www.digispider.net

 

 

CHAPTER 6   FAQs  

1. Can the CFM remember its DSP parameters when restart the device? 

Yes, it can. The user can achieve this function by the confirm operation in the 
NSP-100 software.   
 
2. Does Digispider Inc. recommend any specific Ethernet switches for 
CFM device? 
No, but you must use 100BaseT Ethernet switches. 
 
3. Is CFM compatible with other companies’ Cobranet devices? 
Yes, CFM is compatible with and integrated by other companies’ devices with 
Cobranet interfaces since Cobranet is a standard protocol. 
 
4. Is CFM must be connected to a switch? 
No, the CFM can be used in the stand alone mode via a crossover cable.   
 
5. Must NSP-100 software and CFM device be connected all around the 
time?  

No, it is not necessary. Every CFM device has memory unit. The system setup 
data is downloaded and burned into rewriteable memory in each CFM. After the 
parameter is configured and confirmed, it operates independently with no 
further need for a computer. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание CFM Series

Страница 1: ...pider Inc No part of it may be reproduced transmitted or translated any language without permission from DigiSpider Inc Trademarks as DS Digispider Dspider used in this manual are registered by DigiSp...

Страница 2: ...e electrified still when the equipment is plugged z Installation and servicing should be performed by qualified and experienced personnel z Please make sure all the cables of CFM equipments and periph...

Страница 3: ...ation vent Don t make paper underlie CFM equipment Use CFM equipment in ventilated area and don t locate CFM equipment on bed sofa or carpet z Never spill food or liquid of any kind on the CFM equipme...

Страница 4: ...e belonged to recognized standard of product maintenance deadline If you voluntarily tear up them it will affect to recognize the standard of product maintenance deadline Looking for help Warning Do n...

Страница 5: ...ND REAR PANEL 4 CHAPTER 2 CFM OPERATING PROCESS 8 CFM 1006 8 CFM 0800 12 CHAPTER 3 BASIC OPERATION 14 STAND ALONE MODE 14 EXPAND MODE 15 NETWORK MODE 16 CHAPTER 4 NSP 100 QUICK START FOR CFM 17 CHAPTE...

Страница 6: ...ent research methods for various reading habits If you encounter any unknown words or expressions please refer to the attached Glossary For the person who use the system for the first times We recomme...

Страница 7: ...anges and updating information regularly updated content will be updated to version Digispider Inc may make improvement or updates for the products and procedures described in this document at any tim...

Страница 8: ...ferent requests of different sorts of conferences They are CFM 1006 conference host computer and CFM 800 conference extended unit The detailed features are shown in the diagram Type CFM 1006 Main Unit...

Страница 9: ...w normal operating status 4 LCD While CFM operating LCD would display inform of current mic line or net signals LCD display symbol represents the volume is under the threshold represents the volume is...

Страница 10: ...XD PIN 3 RXD PIN 5 GND PIN 1 4 6 7 8 9 NC 4 Data port reserved 5 Input audio XLR jack Mic Line input port it can provide OdB 66dB mic gain 48V phantom power All of the operation can be controlled via...

Страница 11: ...ontrolled by NSP 100 control software The CobraNet interface also is a Ethernet interface for transmiting control data The parimary port is active when both of the ports are connected The secondary po...

Страница 12: ...m power All of the operation can be controlled via dedicated software NSP 100 Note the pin 2 and pin 3 should not be connected to the pin1 when the 48V phantom power is open otherwise the input port w...

Страница 13: ...igent mixer The detailed process is shown in the diagram Each function module allows for configuration and modification of parameters via NSP 100 software and can download them to the CFM hardware dev...

Страница 14: ...dow from IN1 to IN10 you can open the Mic gain adjustment dialogue window There are total 10 steps to choose after a proper Mic gain rank is selected this detailed gain value will be indicated on the...

Страница 15: ...ators When people who have high priority speak in MIC the low priority people s level in input channel s will be decreased automatically Setting interface is as shown below Priority setting interface...

Страница 16: ...he mixer DSP parameters to default value Copy Atrri Copy the mixer DSP parameters for the other device usage Paste Atrri Paste the mixer DSP parameters from the other CFM Current Input Mix open or clo...

Страница 17: ...nit only has local Mic input ports net input output ports but no analog output ports So it has to be used together with CFM 1006 device for the extension of Mic input ports The process of signal worki...

Страница 18: ...13 Copyright 2009 Digispider All rights reserved www digispider net NSP 100 design Use the CFM 0800 for expand...

Страница 19: ...ftware Recommend to use this mode in small conference discussion system the number of microphone less than 10 and number of mixer less than 6 In stand alone connect the computer network card to the CF...

Страница 20: ...han 10 mic input One CFM 1006 can receive eight CobraNet signal from the network So there are eight CFM 0800 can be connected to the CFM 1008 for expand Step 1 Using switch to set up network between s...

Страница 21: ...rk Step 1 Using switch to set up network between several CFM devices and the controlled computers The maximum length of the CAT 5 cable between the switch and CFM device is 100m Step 2 Startup CFM dev...

Страница 22: ...ed in advance prior to the setup of NSP 100 If your PC has installed CobraNet discovery software before you do not need to install the CNOT tools again But the WinPcap software must be installed 2 Ins...

Страница 23: ...ns of IP address are identical to that of the adapter otherwise the NSP 100 will not be started normally After the all configure is done The NSP 100 could be launched normally Step3 Create a new proje...

Страница 24: ...rdware Configuration Requires Password Authentication The Initial Password Is 1 Please Be Careful to Modify and Safe to keep The Password Enter the NSP 100 device library Clicks Add to add CFM 1006 de...

Страница 25: ...the CobraNet device Segment 2 four characters means the TX1 bundle number must be hex for example txbundle1 500 decimal 01F4 H of the CobraNet device Note TX2 TX1 1 Segment 3 Eight characters serial...

Страница 26: ...ispider net Step6 Configure the serial number for CFM device Right click on the device click the Property and select the right MAC for CFM device and then click OK After allocated the MAC address of t...

Страница 27: ...ports triangle for physical port other non CobraNet devices belong to this type and square for network ports The user could connect the network ports for the virtual connection Step8 Compile After est...

Страница 28: ...download button and then adjust the DSP parameters online In the offline mode the user should edit the DSP parameters before the start to download button Click the start to download button CFM 1006 ca...

Страница 29: ...adjustment window Drag fader to complete adjustment the detailed gain value can be seen on the interface also can be input a certain value in the interface directly for setting input channel gain adj...

Страница 30: ...lly Setting interface as shown below Priority setting interface Priority 0 is the highest 1 is medium 2 is the lowest And the detailed decreasing value can be set between 60 0dB when low priority user...

Страница 31: ...p up the interface as follow Set Atrri to Default set the mixer DSP parameters to default value Copy Atrri Copy the mixer DSP parameters for the other device usage Paste Atrri Paste the mixer DSP para...

Страница 32: ...adjusted and have C L processor The output channel level adjustment is similar with input channel level adjustment The process of C L includes the following 4 main parameters setting and shown as belo...

Страница 33: ...perate on CFM 0800 The device CFM 0800 function setting is as same as CFM 1006 s please refers to CFM 1006 Step 6 Complete and confirmation User can make a conference system based on the above instruc...

Страница 34: ...hms 2 ANALOG AUDIO OUT PUT SPECIFICATION z 24 bit 48khz digital audio converted to analog output z frequency response 0 2dB 20Hz 20kHz z THD plus noise 0 01 4dBu 1KHz z Dynamic range 103dBA 101dB z Ma...

Страница 35: ...other companies Cobranet devices Yes CFM is compatible with and integrated by other companies devices with Cobranet interfaces since Cobranet is a standard protocol 4 Is CFM must be connected to a swi...

Страница 36: ...ports CobraNet interfaces feature built in redundancy with primary and secondary ports for connection to primary and secondary networks If an unrecoverable fault should occur on the primary network C...

Страница 37: ...d automatically route network traffic accordingly so each device receives only data addressed to it COBRANET device A device is designed according to COBRANET technology to receive and transmit audio...

Страница 38: ...lifier and phantom power setting 3 FADVL z xx p aa b Level increase decrease for input output channel setting 4 MIXPR xx p Priority setting 5 MIXEN xx p Channels mix enable setting 6 MIXGN oo ii p aa...

Страница 39: ...ormally Command end character Command character 5 parameters Command parameter z input output character 1 input 2 output xx channel No start from 01 00 stands for all channels Others refer to command...

Страница 40: ...n Note In order to prevent sonic boom after opening phantom power to Open phantom power must use command MIXEN xx p to close this channel s mix function After finish setting wait for a while and then...

Страница 41: ...PR xx p Function Priority level setting Total 3 levels 0 is highest 1 is medium 2 is lowest Instruction xx 2 decimal character input MIC NET 01 18 p 1 decimal character 0 highest 1 medium 2 lowest 5 M...

Страница 42: ...decimal character X 1 means start time X 2 means release time aaa 3 decimal character time aaa 20ms 9 MIXDK x p aa b Function mix DK level if there is audio signal in high priority channel level of lo...

Страница 43: ...n 0dB 48V OFF 2 MIC NET input level 0dB 3 noise gate TH 35dBu Max decrease 30dBu hold time 0 1s BYPASS 0 4 HP filter 0dB 70hz VQ Q 0 707 BYPASS 1 5 LP filter 0db 10Khz VQ Q 0 707 BYPASS 1 6 PQL Freque...

Страница 44: ...39 Copyright 2009 Digispider All rights reserved www digispider net 15 SPK output level 0db 16 C L parameter value 0db compress ratio 2 0 dynamic time 10ms release time 100ms BYPASS 1...

Отзывы: