(3) RMON alarm group configuration page
Figure 57 shows the RMON alarm group configuration page. You can use this page to create or modify
RMON alarm group. Select a configured alarm group from the drop-down list to view/configure its information.
Select New to create it. The index number range is from 1 to 60, and the interval range is from 1 to 3600. In
seconds, the monitoring object must fill in the MIB node. The comparison method can choose absolute
(absolute value) or delta (change amount). In addition, the upper and lower limit valves must be filled. Value,
event index, owner is optional. The alarm value is read-only and shows the sampled value when the alarm was
last issued. The event index refers to the index number of the RMON event group and must be configured in
advance.
Figure 57: RMON Event Group Configuration Page
16
、
Cluster configuration
(1) NDP configuration page
Figure 58 shows the NDP configuration page. You can use this page to configure NDP. The configurable
information includes: selecting the port, enabling the NDP function of the port, enabling the global NDP function,
the interval for sending NDP packets, and the aging time of the NDP packets on the receiving device.
For port selection, you can select the port as required and enable the port NDP function. For NDP to
operate normally, both global and port NDP must be enabled at the same time.
Set the aging time of the NDP packets sent by the local device to the receiving device. The valid time range
is 1-4096 seconds. The default value is 180 seconds.
Set the interval for sending NDP packets. The valid time range is 1-4096 seconds and the default is 60 seconds