DigiPoS PowerPoS Technical Manual
Ventilation Requirements
Cavity Size
If the DigiPoS is to be located in a cavity, i.e. under the counter, the cavity dimensions
must be a minimum of 380mm long by 400mm wide by 120mm deep (excluding the
external PSU). A diagrammatic representation is as follows:
120mm
400mm
Although this is the required space, the DigiPoS MUST be located centrally to prevent the
airflow from being disrupted through the ventilation holes in the sides of the case.
Enclosed Spaces
If the DigiPoS is to be located in an enclosed space, i.e. in a closed box or cabinet, there
must be sufficient airflow into and out of the enclosed space. Using the above cavity
space, for example, forced airflow would have to be fitted to prevent the DigiPoS from
overheating. As a general rule, the DigiPoS PowerPoS requires an airflow exchange rate
of a minimum of 25 CFM (Cubic Feet per Minute) excluding PSU or 30 CFM including
PSU when in an enclosed space.
The recommended location for these fans is as follows:
View From Above
Airflow
Direction
Airflow
Direction
30cfm Fan
Exhaust Vent
DigiPoS
Front
Rear
PSU
Including PSU
View From Above
Airflow
Direction
Airflow
Direction
25cfm Fan
Exhaust Vent
DigiPoS
Front
Rear
Excluding PSU
External PSU
DigiPoS Systems recommends that the external PSU for PowerPoS is not situated in the
same space as the DigiPoS to minimise heat build up in enclosed spaces. If this is
unavoidable, forced air ventilation
must
be installed to provide adequate ventilation for the
DigiPoS & PSU heat dissipation devices.
Page 11 of 82
Содержание PowerPoS
Страница 1: ...DigiPoS PowerPoS Technical Manual Socket 370 Series Manual Version 1 4 June 2004 ...
Страница 29: ...DigiPoS PowerPoS Technical Manual Motherboard Orientation JP1 J7 SW1 Component Side Page 29 of 82 ...
Страница 30: ...DigiPoS PowerPoS Technical Manual Pin1 HDD Connector COM 2 COM 1 Underside Page 30 of 82 ...
Страница 80: ...DigiPoS PowerPoS Technical Manual Notes Signed Print Page 80 of 82 ...