OPERATING CAMERA

Down Button
Up
Enter
Right
Left
Spot Video Out

1
2
3
4
5

The housing can also 
be mounted on a 4s
electrical box.  

MOUNTING HOUSING TO 
AN ELECTRICAL BACK BOX

Electrical box

Torx screws

UNC 8-32 x 0.75

Rubber

Washers(4x)

1 2 3 4 5

Figure 3

CEILING

Drilling 
Guide Label

Plastic Anchor(4x)

Rubber Washers(4x)

Mounting Screw

M6X35(4x)

- 3 -

Note: Electrical box is not supplied.

6

6

Содержание DPV14W

Страница 1: ...V I S I O N POLARIS model DPV14W...

Страница 2: ...for several days or more To disconnect the cord pull it out by the plug Never pull the cord itself Allow adequate air circulation to prevent internal heat build up Do not place the unit on surfaces ru...

Страница 3: ...NCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXP...

Страница 4: ...than 17 that specified 17 CAUTION these servicing instructions are for use by qualified service personnel only to reduce the risk of electric shock do not perform any servicing other than that contai...

Страница 5: ...ance modes Day Night Auto OFF AGC Auto Gain Control VIDEO OUT BNC Internal AC line lock Operates in 12VDC or 24VAC Use Certified Listed Class 2 power supply only 2 8 12mm Day Night A I Varifocal Lens...

Страница 6: ...g the housing using the loosen torx screws Fig 3 Torx screws M5x10 4x Figure 1 Figure 2 Torx screws M5x10 4x Seal around the housing base tightly using the silicon rubber 2 1 Lens 2 8 12mm D N A I Var...

Страница 7: ...lso be mounted on a 4s electrical box MOUNTING HOUSING TO AN ELECTRICAL BACK BOX Electrical box Torx screws UNC 8 32 x 0 75 Rubber Washers 4x 1 2 3 4 5 Figure 3 CEILING Drilling Guide Label Plastic An...

Страница 8: ...W NORMAL HIGH WHITE BALANCE ATW Normal ATW Xtnd AWB SYNC INTERNAL LINELOCK AUTO OFF D N CONTROL SAVE EXIT CANCEL PUSH AWB CONFIRM Save AWB ALL Chngs CANCEL WARNING will ALL User be written to ROM prop...

Страница 9: ...hite balance is automatically followed up ATW Normal W Limits the range of auto tracking by the value of two properties When shooting in a bright area outdoors W ATW Xtnd hite balance is automatically...

Страница 10: ......

Страница 11: ...ens 2 Pin wire 2 Pin terminal block f 2 8 12mm F1 4 Varifocal DC auto iris ICR 0 5 Lux Color 0 01 Lux B W F1 2 50IRE o o o o 10 C 50 C 14 F 122 F PRESETS Default Indoor Outdoor ATW Normal ATW Xtnd AWB...

Страница 12: ...Unit Shipping Unit mm 0 1 in 2 5mm thick impact resistant P C LEXAN 3 93 in 10cm diameter One 1 opening holes 1 54 lb 0 7kg 2 11 lb 0 96 kg 146 3 PF 3 4 TAP o 4 5o 4 5 1 0 1 2 113 7 4 6 4 50302660A 5...

Отзывы: