Hybrid Inverter Users’ Manual 

Page | 10   

DC Input low voltage soft start   

11.7V±0.5VDC 

DC Input high voltage protection   

16.5±0.5VDC 

DC Input high voltage soft start   

15.5V±0.5VDC 

Quiescent Input current 

2A 

AC Output voltage 

230VAC±5V (GS) 120VAC±5V (UL)

Continuous Power   

1500W 

Overload Protection   

1650-1900W 

Alarm 30S 

Surge Power   

3000W 

Frequency  

60/50±0.5Hz (Switch) 

Wave Form   

Pure Sine Wave   

THD Line 

load

3% 

Efficiency  

80% 

Over Temperature Protection     

65

 

DC Input Fuse   

40A×6 

Remote Controller  

Bluetooth  

AC 

GS UL 

AC Input Range   

90VAC~ 264VAC 90VAC~132V AC

AC Input voltage   

AC 230V 

AC120V 

Frequency  

50/ 60±5Hz 

60±5Hz 

AC Input Quiescent current 

0.08A 

AC Output watt (by pass)   

1500W 

Содержание UP-8B5N

Страница 1: ...Hybrid Inverter Users Manual Page 1 1500 WATT HYBRID INVERTER SOLAR INVERTER AC MAINS Users Manual...

Страница 2: ...The 230 volt AC can NOT be converted to 12 volt DC to only charge the battery bank that is connected Do NOT place the inverter near flammable materials or any location which accumulate flammable fume...

Страница 3: ...Hybrid Inverter Users Manual Page 3 4 Names and Functions Front Panel Power Output and Back Panel Power Input...

Страница 4: ...LCD Display switch 5 How to Connect the Hybrid Inverter in Your Facilities 1 Connect the battery terminals with the battery as shown in Step 1 Please ensure the polarity is correct 2 Connect the solar...

Страница 5: ...erter and the power source Check the connections with exposed conductive parts Blown fuse in the inverter Replace the fuse No AC output voltage Over temperature protection Check for adequate ventilati...

Страница 6: ...ry is old or defective Replace the battery The battery capacity is too small Use a higher capacity battery Charger failure no charge voltage The battery voltage is too low to be charged Change the bat...

Страница 7: ...If the battery voltage drops to 12 8 volt the MCU will once again start charging t7 When the load requirement is less than the energy provided by the chargers the battery voltage will climb slowly On...

Страница 8: ...load through the battery Users can also press the AC DC priority switch to set the DC first mode as the battery discharges below 15 volt t3 When the battery drops below 12 8 volt the MCU will once ag...

Страница 9: ...keep loads running t10 When the battery drops below 12 8 volt the MCU will once again start up the solar charger instead of the AC charger in order to save energy t11 As the battery voltage falls as l...

Страница 10: ...120VAC 5V UL Continuous Power 1500W Overload Protection 1650 1900W Alarm 30S Surge Power 3000W Frequency 60 50 0 5Hz Switch Wave Form Pure Sine Wave THD Line load 3 Efficiency 80 Over Temperature Pro...

Страница 11: ...ge ragne 10 15VDC Charger output current 10A 12VDC 10 Max charge voltage 15VDC 0 3V Efficiency 80 Output short circit protection OK Reverse battery protection OK Battery high voltage protection 15VDC...