background image

Page  

  

 P/N: RF160IRG  Rev 1.0

E&OE   

Copyright © 2021

The 2 Channel SMART RF Wireless Output Module, is 

an advanced 433MHz RF transceiver with 2 indepen-

dently controllable relay outputs. Output functionality is 

configured via panel programming, and any number of 

RF outputs can be used, up to the maximum number of 

outputs supported on the panel.  

 

The panel must be fitted with one or more RF120 and/or 

RF121 Smart RF Receivers (V2.51or higher).  

 

The unit is compact so it can easily fit inside a gate 

controller cabinet or can be mounted easily to most 

surfaces. The wide operating voltage 9 to 28 volts AC/DC 

makes it easy to power from third-party controllers or 

power supplies.

The 2-Way communication protocol is encrypted with 

rolling code and anti substitution technology making 

the RF160 an ideal choice for controlling gates, garage 

doors, lights or security systems.

Box Contents

The RF160 box contains the following parts.

2 Channel SMART RF Stand Alone Controller
1 x Antenna Instruction Sheet

Compatible Keyfobs

RF110 Smart 5 Button Keyfob
RF110FK - Colour Facia Kit One Of Each Colour 

(Red, Blue, Green, Orange, Black, Grey, Yellow)

Figure 1: RF110 Smart 5 Button Keyfob

Mounting Considerations:

• 

The receiver should be mounted in a location at 

least 2 metres from other receivers.

RF160 - 2CH SMART RF Output Module - 433MHz

• 

The receiver should be mounted on a vertical sur-

face with at least 30cm clearance from metal objects. 

• 

Avoid mounting the receiver in areas with significant 

metal or electrical wiring. 

• 

Avoid mounting the receiver in areas where it may 

be exposed to moisture or high humidity. 

• 

Reception distances are generally improved with 

higher mounting locations and with no metal ob-

jects near the unit. 

• 

If range is not achievable due to environmental or 

specification limitations then look at relocating the 

unit to a more appropriate location.

Receiver Operation

The RF160 will turn on the green RX LED to indicate the 

unit is powered and it will blink off each time a signal is 

received. Each time a Keyfob button is pressed the corre-

sponding relay will operate and a confirmation signal is 

sent to the Keyfob to indicate a successful 2 way transac-

tion. When button RLY1 or RLY2 are triggered manually 

they operate the corresponding relay to allow you to 

test your connections and device your operating.

WARNING

 always be sure to check that there is no ob-

jects in the way when operating an automatic device as 

this could cause damage or injury to a person. 

Relay Programming

Before configuring RF outputs, the control panel needs 

to be communicating to an existing Digiflex smart RF 

receiver (refer to both the control panel and smart RF 

receiver installation manuals for further information).

You need to configure an output at the control panel 

from the available event types provided - refer to the 

control panel installation manual for further information.  

Each relay on the RF160 can follow a single control panel 

output when the event occurs.

Configuring Output At Control Panel - Example

The example below will configure an output to operate a 

garage door controller (in this example using output 6).

MENU 4-1-0  Output Name < Garage Door >
MENU 4-1-1  Event Type < 60 = Door >
MENU 4-1-2  Event Assignment < 01 = Door 1 Name >
MENU 4-1-3  Output Polarity < 04 = Open, 1 Shot Low >
MENU 4-1-4  Output Time Parameter < 001 Second >

Содержание RF160

Страница 1: ...Installer Reference Guide RF160 2 Channel SMART RF Wireless Output Module 433MHz Rev 1 0 RoHS ...

Страница 2: ...xposed to moisture or high humidity Reception distances are generally improved with higher mounting locations and with no metal ob jects near the unit If range is not achievable due to environmental or specification limitations then look at relocating the unit to a more appropriate location Receiver Operation The RF160 will turn on the green RX LED to indicate the unit is powered and it will blink...

Страница 3: ...or 0F9105130 Press OK or MENU 4 Press OK to save and exit or press MENU to exit without saving Relay 1 Relay 2 Exit Press OK or MENU 5 Select Relay 1 to use relay 1 or select Relay 2 to use relay 2 of the RF160 module then press OK to save and exit or press MENU to exit without saving Delete RF Device This menu allows the installer to delete a relay on the RF160 module This menu does not delete th...

Страница 4: ...oke Sensor PWR Press OK or MENU 2 The keypad will display the current RF160 ID Op6 Garage Door Waiting for Trigger Press OK or MENU 3 Press and hold both relay buttons on the RF160 module to transmit a packet signal Op6 Garage Door Rx3 Packets 001 v2 02 Signal Good 247 Press OK or MENU 4 Press OK or press MENU to exit The keypad will display the receiver address that re ceived the packet signal fr...

Страница 5: ...ion Diagram Connection Diagram Antenna connects here Relay 1 terminal connections are used to connect to a 3rd party device Relay 2 terminal connections are used to connect to a 3rd party device Relay 1 and Relay 2 can be manually operated by pressing their respective buttons Power input A C or D C 9 28 V ...

Страница 6: ... a terminal cover The top cover is fixed to the base using a Phillips head screw The top cover needs to be removed to install the wire antenna The terminal cover is a press fit allowing easy removal Once the wiring and programming has been completed the cover should be reinstalled to help prevent the ingress of insects and other debris Wall Mounting A wall mounting tab is located on the inside of ...

Страница 7: ...ision X Solution 6000 V2 53 18 or higher Dimensions 114mm W 128mm W with Mounting Tab 62mm D 28mm H Environment 0 to 49 C Indoors Fixing Method Using mounting screws fix unit on a vertical surface in portrait orientation Relay Outputs Contact Rating 1A 30V D C Warranty 3 years from date of manufacture return to base RoHS In the interest of ongoing product development this document is subject to ch...

Страница 8: ... Digiflex Pty Ltd P N RF160IRG Rev 1 0 DIGIFLEX PTY LTD 18 Brumby Street Seven Hills NSW 2147 AUSTRALIA Phone 612 97417000 Email sales digiflex com au www digiflex com au Our Vision Is Your Peace Of Mind Made in Australia ...

Отзывы: