P/N: RF159IRG Rev 1.3
Page
3
Copyright © 2020
E&OE
Receiver Operation
The RF159 will turn on the green RX LED to indicate the unit is powered and it will blink off each time a signal is re-
ceived. Each time a keyfob button is pressed the corresponding relay will operate and a confirmation signal is sent to
the keyfob to indicate a successful 2 way transaction. When button RLY1 or RLY2 are triggered manually they operate
the corresponding relay to allow you to test your connections and device your operating.
WARNING
always be sure to check that there is no objects in the way when operating an automatic device as this
could cause damage or injury to a person.
Relay Programming
RLY1 and RLY2 can be individually programmed to operate in pulse or toggle mode by selecting the corresponding
mode number. Pulse mode is available in different timings from 1 second to 120 seconds to allow easy interface to
automatic gates and doors . Toggle mode will operate the relay when the keyfob button is pressed and will release
the relay on the next keyfob button press.
Program Relay Functions
Action
Steps
LED’s
Comment
1
Enter Relay
Programing Mode
Press RLY1 and RLY2 For 4
seconds
RF: ON
PGM: ON
RLY1: ON
RLY2: ON
PGM
RLY1
RLY2
RF
2
Selecting The Relay
Press Relay Button To
Select (
E.g. RLY1
)
RF: ON
PGM: ON
RLY1: Pulse current mode
RLY2: OFF
PGM
RLY1
RLY2
RF
RLY1 LED will flash the number of times corresponding to the currently programmed setting.
3
Set Relay Mode
Press Relay Button To
Change Mode (
E.g. RLY1
)
RF: ON
PGM: ON
RLY1: Pulse current mode
RLY2: OFF
PGM
RLY1
RLY2
RF
RLY1 LED will flash the number of times corresponding to the currently programmed setting, pause then repeat.
Each time you press RLY1 it will increment to the next mode as follows.
1=1s,
2=2s
, 3=3s, 4=4s, 5=5s, 6=10s, 7=20s, 8=60s, 9=120s, 10=toggle
4
Program Other
Relay
Press Relay Button To
Select (
E.g. RLY2
)
RF: ON
PGM: ON
RLY1: OFF
RLY2: Pulse current mode
PGM
RLY1
RLY2
RF
RLY1 LED will flash the number of times corresponding to the currently programmed setting, pause then repeat.
Each time you press RLY1 it will increment to the next mode as follows.
1=1s,
2=2s
, 3=3s, 4=4s, 5=5s, 6=10s, 7=20s, 8=60s, 9=120s, 10=toggle
5
Exit Programming
Mode
Press RLY1 and RLY2 for 1
seconds or timeout
after 60 seconds
RF: On
PGM: OFF
RLY1: OFF
RLY2: OFF
PGM
RLY1
RLY2
RF
LED Legend
Fast Flash
Red
Slow Flash
Red
Steady On
Red
Steady
Green
OFF
Table 1: RF159 Relay Programming