Receiver Operation

The RF159 will turn on the green RX LED to indicate the unit is powered and it will blink off each time a signal is re-
ceived. Each time a keyfob button is pressed the corresponding relay will operate and a confirmation signal is sent to 
the keyfob to indicate a successful 2 way transaction. When button RLY1 or RLY2 are triggered manually they operate 
the corresponding relay to allow you to test your connections and device your operating.

WARNING

 always be sure to check that there is no objects in the way when operating an automatic device as this 

could cause damage or injury to a person. 

Relay Programming

RLY1 and RLY2 can be individually programmed to operate in pulse or toggle mode by selecting the corresponding 
mode number. Pulse mode is available in different timings from 1 second to 120 seconds to allow easy interface to 
automatic gates and doors . Toggle mode will operate the relay when the keyfob button is pressed and will release 
the relay on the next keyfob button press.

Program Relay Functions

Action

Steps

LED’s

Comment

1

Enter Relay 

Programing Mode

Press RLY1 and RLY2 For 4 

seconds

RF: ON 

PGM: ON 
RLY1: ON 
RLY2: ON

PGM

RLY1

RLY2

RF

2

Selecting The Relay

Press Relay Button To 

Select (

E.g. RLY1

)

RF: ON 

PGM: ON 

RLY1: Pulse current mode 

RLY2: OFF

PGM

RLY1

RLY2

RF

RLY1 LED will flash the number of times corresponding to the currently programmed setting.

3

Set Relay Mode

Press Relay Button To 

Change Mode (

E.g. RLY1

)

RF: ON 

PGM: ON 

RLY1: Pulse current mode 

RLY2: OFF

PGM

RLY1

RLY2

RF

RLY1 LED will flash the number of times corresponding to the currently programmed setting, pause then repeat.

Each time you press RLY1 it will increment to the next mode as follows. 

1=1s,  

2=2s

,  3=3s, 4=4s,  5=5s,  6=10s,  7=20s,  8=60s,  9=120s,  10=toggle

4

Program Other 

Relay

Press Relay Button To 

Select (

E.g. RLY2

)

RF: ON 

PGM: ON

RLY1: OFF 

RLY2: Pulse current mode

PGM

RLY1

RLY2

RF

RLY1 LED will flash the number of times corresponding to the currently programmed setting, pause then repeat.

Each time you press RLY1 it will increment to the next mode as follows. 

1=1s,  

2=2s

,  3=3s, 4=4s,  5=5s,  6=10s,  7=20s,  8=60s,  9=120s,  10=toggle

5

Exit Programming 

Mode

Press RLY1 and RLY2 for 1 

seconds or timeout

after 60 seconds

RF: On 

PGM: OFF 
RLY1: OFF 
RLY2: OFF

PGM

RLY1

RLY2

RF

LED Legend

 

Fast Flash

Red

Slow Flash

Red

Steady On

Red

Steady

Green

OFF

Table 1: RF159  Relay Programming 

Содержание RF159

Страница 1: ...Installer Reference Guide RF159 2 Channel SMART RF Controller 433MHz Rev 1 3 RoHS ...

Страница 2: ...ur Red Blue Green Orange Black Grey Yellow Figure 1 RF110 Smart 5 Button Keyfob RF159 2CH SMART RF Controller 433MHz Mounting Considerations The receiver should be mounted in a location at least 2m from other receivers The receiver should be mounted on a vertical surface with at least 30 cm clearance from metal objects Avoid mounting the receiver in areas with significant metal or electrical wirin...

Страница 3: ... s Comment 1 Enter Relay Programing Mode Press RLY1 and RLY2 For 4 seconds RF ON PGM ON RLY1 ON RLY2 ON PGM RLY1 RLY2 RF 2 Selecting The Relay Press Relay Button To Select E g RLY1 RF ON PGM ON RLY1 Pulse current mode RLY2 OFF PGM RLY1 RLY2 RF RLY1 LED will flash the number of times corresponding to the currently programmed setting 3 Set Relay Mode Press Relay Button To Change Mode E g RLY1 RF ON ...

Страница 4: ...to Relay Press desired keyfob button to learn RX Acknowledged with a singal pulse PGM ON RLY1 Flash RLY2 Flash PGM RLY1 RLY2 RF To program another keyfob or button go to step 2 4 Exit Programming Mode Press RLY1 and RLY2 for 1 second or timeout after 60 seconds RX ON PGM OFF RLY1 OFF RLY2 OFF PGM RLY1 RLY2 RF LED Legend Fast Flash Red Slow Flash Red Steady On Red Steady Green OFF Table 2 RF159 Key...

Страница 5: ...ion Diagram Connection Diagram Antenna connects here Relay 1 terminal connections are used to connect to a 3rd party device Relay 2 terminal connections are used to connect to a 3rd party device Relay 1 and Relay 2 can be manually operated by pressing their respective buttons Power input A C or D C 9 28 V ...

Страница 6: ...nd a terminal cover The top cover is fixed to the base using a Phillips head screw The top cover needs to be removed to install the wire antenna The terminal cover is a press fit allowing easy removal Once the wiring and programming has been completed the cover should be reinstalled to help prevent the ingress of insects and other debris Wall Mounting A wall mounting tab is located on the inside o...

Страница 7: ...ut Power 0 99 dBM Dimensions 114mm W 128mm W with Mounting Tab 62mm D 28mm H Environment 0 to 49 C Indoors Fixing Method Using mounting screws fix unit on a vertical surface in portrait orientation Relay Outputs Contact Rating 1A 30V D C Warranty 3 years from date of manufacture return to base RoHS In the interest of ongoing product development this document is subject to change without notice ...