Chapter 4: Using SYNC HD
35
Front Panel
Generator/Parameter
Switches
The Generator/Parameter Controls are labelled
SET, DOWN, UP, and RUN/STOP/CLEAR/ESC.
In addition to their primary generator func-
tions, these switches provide front panel access
to most SYNC HD parameters.
Features Not Accessible from the SYNC HD
Front Panel Controls
The front panel provides access to all SYNC HD
features except the following, which can be con-
trolled using Pro Tools or the SYNC Setup soft-
ware utility (Windows only):
• Remote-Only Mode/Front Panel Lockout
• Changing Window Burn Size, Vertical Posi-
tion, Horizontal Position, and Color
• GPI (General Purpose Interface) functions
• Variable Speed Offset (VSO)
For a listing of available parameters, see Table 5
on page 34.
Set
The SET switch has three primary functions:
When time code is displayed
Press Set once to
change the Display from time code to parameter
names.
When a parameter name is visible
Press Set once
to change the Display to show parameter
values
.
When a parameter value is visible
Press Set once
to set the value for that parameter and return
the Display to time code.
Down and Up
These switches scroll through parameter names
or values:
When a parameter name is visible
Press the
Down and Up switches to scroll through the pa-
rameter names (for example, from “SET GEn” to
“VIdEo SY”).
When a parameter value is visible
Press the
Down and Up switches to scroll through the
range of values for the current parameter.
When entering time code values
Press the Down
and Up switches simultaneously to cycle
through the hours:minutes:seconds:frames
fields in the time code display.
Run/Stop/Clear/Esc
This switch has two functions, depending on
the current mode:
While generating time code
Press
RUN/STOP/CLEAR/ESC to start or stop the time
code generator when the SYNC HD is in Gener-
ator Preset mode.
While time code is being displayed
Press
RUN/STOP/CLEAR/ESC to reset the counter
whenever time code is visible in the LED Time
Code display.
Otherwise, the RUN/STOP/CLEAR/ESC switch
serves as a Cancel button.
Generator/Parameter Switches
DF
SET
DOWN
UP
RUN/STOP
CLEAR
LTC
VITC
BI-PHASE
GENERATE
POSITIONAL
REFERENCE
Содержание SYNC HD