7.2 Solving problems
clip
Defect
Possible causes
Action
Will not turn on
The power supply
cable is not connected
properly.
The fuse of the power
supply is blown.
Check the cables and
the fuse (fuse:3A).
Does not activate the
electromagnet (turnstile
cannot be locked)
The cable is broken or
the distance between
the electromagnet and
the locking device is
maladjusted.
Adjust the
electromagnet or
forward the
equipament to the
Technical Assistance.
The arm does not remain
in the correct position
There is wear, dirt, a
broken spring or lack
of lubrication in the
sphere base.
Request a replacement
for the faulty part or
forward the
equipament to the
Technical Assistance.
CATRAX Fit does not lock
in the first tooth
The distance between
the electromagnet and
the locking device is
maladjusted.
Adjust the
electromagnet or
forward the
equipament to the
Technical Assistance.