32
7.2 Defects and possible causes
Defect
Possible causes
Action
·
Catrax Plus will not
turn on
·
The power supply’ input cable is not connected
properly;
·
The circuit breaker is off.
·
Check the cables and the fuse.
·
Catrax Plus is
locked
·
Optical sensors obstructed or defective.
·
Perform the preventive routine
maintenance on the sensor or
formward the equipment to the
Technical Assistance.
·
Catrax Plus does
not activate the
electromagnet
(turnstile cannot be
locked).
·
The cable is broken or the distance between the
electromagnet and the locking device is
maladjusted.
·
Adjust the electromagnet or
fordward the equipament to the
Technical Asistance.
·
The arm does not
remain in the
correct position
·
There is wear, dirt, a broken sprong or lack of
lubrication in the sphere base
·
Request a replace ment for the
faulty part of forward the
equipament to the Technical
Assistance.
·
A Catrax Automatic
Plus does not in the
first toot.
·
The distance between the electromagnet and the
locking device is maladjusted.
·
Adjust the electromagnet or
forward the equipament to the
Technical Assistance.