![digicon catrax automatic plus Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/digicon/catrax-automatic-plus/catrax-automatic-plus_product-manual_2497094025.webp)
25
6.5.2.4 Connection scheme
Vcc
6.5.2.3 Sound alarm
The sound alarm output is activated by a NPN transistor (maximum 500 mA) every
time that CATRAX Automatic Plus:
-receives a clearance signal (two short rings)
-is not cleared and is forced during 1 second (1-second rings)
-is stuck mid-turn for over 2 seconds (1-second rings)
Connect the outputs according to the following image:
Sound
alarm
Maximum current 500mA
Inputs
Outputs
Relay
Access control board
Inputs
Digicon Control board
Outputs
R
eturn signals