background image

Product Manual

Содержание catrax automatic plus

Страница 1: ...Product Manual ...

Страница 2: ......

Страница 3: ...ed stored in a retrieval system translated into any language or computer language in any electronic magnetic optical chemical manual way or otherwise without the express written permission from Digicon S A Manual code 069 31 237 English Revision 03 This manual was elaborated by Digicon S A Controle Eletrônico para Mecânica Documentation Sector EDS ...

Страница 4: ...over 5 6 Connection to power network 6 Installing assembling optional items 6 1 Collecting box kit 6 1 1 Connection of collecting box kit to control board 6 2 Pictogram Kit 6 3 Power supply 6 4 Electromechanical counter kit 6 5 Control board 6 5 1 Inputs 6 5 2 Outputs 6 5 2 1 Return signal 6 5 2 2 Electromagnets 6 5 2 3 Sound alarm 6 5 2 4 Connection scheme 6 5 2 5 Pictogram 6 5 2 6 Pictogram s co...

Страница 5: ...ates something Digicon considers important CAUTION Indicates a moment of extreme caution when handling the equipment product ATTENTION Indicates a moment when your observation skills should be extremely productive INFORMATION Presents interesting facts about the purchased product QR CODE Presents additional information or links with more details about the presented text ...

Страница 6: ...is manual and cannot be held responsible for errors it may contain and problems due to its use The information contained in this manual is exclusive property of Digicon and is protected by copyright laws This manual cannot be reproduced photocopied or translated in its entirety or in part into any kind of medium without Digicon s written consent 3 Introduction Following a new technological concept...

Страница 7: ...with electrostatic painting in black epoxy powder It has reinforced structure fully rounded corners and non exposed screws offering space and comfort for any access control solution Aiming at facilitating assembly and maintenance the column CATRAX Automatic Plus presents a U shaped internal support mounting rack with standard holes for the fixation of additional electronic boards Moreover the clie...

Страница 8: ...t can also present slots for optional items such as pictogram collecting box input display kit separate manual or a combination of these items The following images show some of the options Besides compatibility with most available technologies Digicon can provide the following optional items collecting kit with box counter kit power supply MCA board and display kit Contactless card reader Flat Car...

Страница 9: ... returning signal will be sent informing the passage direction After the signal the arm cannot be returned to the previous position Depending on the CATRAX Automatic Plus model and configuration if the passage is forced without the enabling signal an electromagnet will be activated to prevent turn In addition the equipment can emit a signal for a sound alarm and or the exhibition of a red X on the...

Страница 10: ...TION To avoid losses the screws and the wrenches used for assembling the CATRAX Automatic Plus are attached to the box containing the arms Before discarding the packing materials cardboard and plastics make sure all the items in the checklist are accounted for Plastic cover kit Arm Lock to access the column Column door Upper pictogram kit optional Collecting box kit optional Stainless steel sheet ...

Страница 11: ... is assembled 6 If the floor is in conditions to receive anchor bolts minimum of 4 cm of FCK15 M P A concrete or equivalent 5 3 Column fixation To fix the column to the floor observe the following steps and the indicated images 1 rill the floor with 3 8 drills then use a 12mm or the drill Make four external D holes according to the measures indicated in the image below INFORMATION Besides the item...

Страница 12: ...TRAX Automatic Plus s arms and upper frontal cover with assembling instructions Arm Screw M3x8 Flat washer M3 Screwa access cover Allen M6x20 Screw Spring washer M6 INFORMATION n the central slot destined to the passage of cables it is I necessary to measure the cables according to the opening s size TIP As an optional item Digicon can provide a steel template for fixing CATRAX Automatic Plus cont...

Страница 13: ...anel s rear cover The image below shows the parts corresponding to each phase Frontal plastic cover set Front stainless steel sheet Collecting box s socket kit Rear stainless steel cover Pictogram s acrylic Flat washer M3 spring washer M3 and hex nut M3 ...

Страница 14: ...one with the key that accompanies the equipment in three ways 5 5 1 Rear cover 1º Open the lock with the smaller key clockwise 2º Carefully raise the cover 3º Brag the cover backwards As shown below 5 5 2 front cover 1º Unscrew the screws inside the turnstile that hold the cover 2º Unscrew the screws out of the cover 3º Pull the cover upwards As shown below ...

Страница 15: ...15 5 5 3 Column door 1º Open the lock with the smaller key clockwise 2º Pull the cover forward 3º The cover will be loose As shown below ...

Страница 16: ...st be type CAT5E Manufacturers FURUKAWA and AMP 5 6 Connecting to power and data networks The Turnstile is powered by a 24 Vcc supply located inside the turnstile The ower p supply can be of 100 to 240 Vca Digicon recommends the regulation NBR 5410 as reference to the equipment s electrical connections In one of its columns the turnstile has circuit breakers in its columns where the power cables e...

Страница 17: ...he equipment s performance to the client s needs See the description of each of these items 6 1 Collecting box kit The collecting box kit has a device for collecting retaining and gathering cards or badges It is ideal for places with eventual visitors or users The kit is composed of a socket a retention device activated by a solenoid and a storage box The image below shows the items that accompany...

Страница 18: ...togram kit visually signals the direction of passage green arrows or the blocking red X To see the items that accompany the pictogram kit and details about its assembly see the product guide Sensor used for collecting the card after 1 5 seconds For access control board The box for cards is part of the kit and is positioned under the collecting kit The badge reader is not part of the kit INFORMATIO...

Страница 19: ...mage below the supply has a short circuit and overheating protection 6 4 Kit contador eletromecânico Among the main advantages of this optional item is its adaptation capability to the voltage variations often found in installation sites the input voltage can vary between 100 and 240 Vca The supply s specific technical features protections and dimensions were carefully tested and approved in hosti...

Страница 20: ... technologies of access control terminals in the market The controller have mechanical features and layout perfectly suited for the CATRAX Automatic Plus s needs and it is one of the best options for the equipment s operation The following images show the control board with its straps connectors and dipswitch as well as the location of the power supply and the control board in CATRAX Automatic Plu...

Страница 21: ...INPUTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 BOX SENSOR LED anode Box signal GND GND Vext1 enables turn through voltage HAB1 enables turn through dry contact from right to left GND Vext2 enables turn through voltage HAB2 enables urn through dry contact from left to right GND 24Vcc avalable to auxiliary maximum 500mA Vext3 enables turn through voltage BQC activates anti panic system GND Output for...

Страница 22: ...d wire 9 GND indicative arrows power black wire 10 solenoid of badge collector box 11 solenoid of badge collector box 12 Sound signal open collector NPN CN10 SOL BQC 1 24Vca 2 SI NAL G CN14 BQC SENSOR 1 24Vca 2 SI NAL G CN18 ELETROÍMÃS 1 ele 1 ctromagnet ele 1 ctromagnet ele ctromagnet 2 2 3 ele 2 ctromagnet 4 The following sections concern important aspects of CATRAX Automatic Plus s control boar...

Страница 23: ...to 24 Vca cc from 110 to 220 Vca cc To enable passage through relay contact or pushbutton make the connection as shown below Enabling passage through tension pulse is shown in the image below It is necessary to observe the polarity of the CC voltages and to use an external resistor for high voltages 110V and 220Vca Vcc Vca ou Vcc Vca ou Vcc NO or NC contact ...

Страница 24: ...lly open contact NO or normally closed contact NC Connect the outputs according to the image below 6 5 2 2 Electromagnets Electromagnets are activated for blocking the turnstile Opposite to the traditional solenoids electromagnets do not cause abrasion between the coil and the locking device avoiding malfunctions Moreover the activation is done through a transistor and not a relay avoiding the ele...

Страница 25: ...utomatic Plus receives a clearance signal two short rings is not cleared and is forced during 1 second 1 second rings is stuck mid turn for over 2 seconds 1 second rings Connect the outputs according to the following image Sound alarm Maximum current 500mA Inputs Outputs Relay Access control board Inputs Digicon Control board Outputs Return signals ...

Страница 26: ...nnections 6 5 3 Configuration of control board Switch Ds1 and Ds2 The switch or dipswitch DS1 allows programming the following actions passage direction Maximum time for turns NO inputs relay or pushbutton contact normally open and without input voltage enabling passage in face of these signals or NC inputs relay or pushbutton contact usually closed and with input voltage enabling passage in the a...

Страница 27: ...noro na metada do giro ON Desabilita Sinal Sonoro na metada do giro OFF Espera até a primeira passagem Sem Timeout de giro ON ON 05segundos catraca 120 OFF ON 10segundos catraca 120 ON OFF 15segundos catraca 120 OFF OFF DIP SWITCH DS1 KEY 1 2 3 4 5 6 7 8 Enables invitation ON Disables invitation OFF Nominal speed ON Half nominal speed OFF Enables clockwise counting ON Disables clockwise counting O...

Страница 28: ... the arm raised during normal operation In case of power outage when the installation has no no break or through a command sent via system or the activation of an emergency button in the control room the electromechanical device is deactivated dropping the arm that prevents turn clearing the entrance of any barrier This device can be connected in series allowing the clearance of all turnstiles at ...

Страница 29: ...st be tightened to the maximum to ensure good fixation All three arms must be attached to the same central upper point Repeat this operation in the three arms and make sure all of them are well fixed INFORMATION The cover for accessing the screws is fitted into place for pening closing o it To assemble the arms of CATRAX Automatic Plus use an Allen n 8 wrench 1 st Let the mini arm dop 2 Make sure ...

Страница 30: ... technician or a qualified company Each inspection should carry out the following operational sequence for each of the three arms set the arm on the horizontal position turn the turnstile off check if the arm drops if the arm does not drop contact the dealer or Digicon turn the turnstile on raise the arm until it reaches its normal position the arm must stay in horizontal position without external...

Страница 31: ...and press the electromagnet against the lock s frame so that its area is completely against the electromagnet 3 refasten the screws Set of locks Periodicity every 700 000 cycles To check for the need of corrective actions you must check the lock s correct position check the wear of the lock s fitting in the sprocket Corrective actions 1 if the lock s position is incorrect check the retaining ring ...

Страница 32: ...nstile cannot be locked The cable is broken or the distance between the electromagnet and the locking device is maladjusted Adjust the electromagnet or fordward the equipament to the Technical Asistance The arm does not remain in the correct position There is wear dirt a broken sprong or lack of lubrication in the sphere base Request a replace ment for the faulty part of forward the equipament to ...

Страница 33: ...33 8 Technical characteristics Dimensions 243 9 566 300 11 811 510 20 078 1042 41 023 digicon Catrax www catrax com br 17 440 ...

Страница 34: ... Electromagnet s power 24 V 2 cc A Input ca ca Z 100 V a 240 V 60H Output cc 24 0 V 5 4 5 A De 0º a 50º C C INFORMATION The measures in the images are given in milimeters 34 Distance between arms Power supply Operational temperature Power Consumption during rotation is 36W ...

Страница 35: ...rs or technical assistance 3 Warranty shall be granted to the buyer only in the face of the bill of sale original or copy 4 Warranty does not apply in the following cases or conditions a defects and damages caused by accidents negligence or reasons of force majeure b defects and damages caused by inappropriate storage or lack of prolonged use c defects and damages caused by improper use of the equ...

Страница 36: ......

Страница 37: ...94045 420 Vendas 0xx51 3489 8700 3489 8745 Assistência técnica 0xx51 3489 8903 E mail vendas acesso digicon com br Filial SP Desenvolvimento e Vendas Assistência Técnica Rua São Paulo 82 Alphaville Barueri SP CEP 06465 130 Fone 0xx11 3738 3500 E mail vendas acesso digicon com br Home page www digicon com br ...