background image

LEONARDO 56

V

DECLARATION 

 OF CONFORMITY

Digicom S.p.A. via Alessandro Volta 39 21010 Cardano al Campo -Varese-

declares that this product satisfies the basic requirements of

Electromagnetic Compatibility and Safety of the below indicated Directive:

l

89/336/CEE of 3 may 1989 with subsequent modifications (Directive 92/
31/CEE of april 28, 1992, Directive 93/68/CEE of july 22,1993 and Directive
93/97/CEE of 29 october 1993).

l

73/23/CEE of february 19, 1973 with subsequent modifications (Directive
93/68 ECC of july 22, 1993).

CHECK REPORT

The equipment has been successfully tested according to the check procedure
indicated on the inside back cover of the user's manual. It is in conformity
with the technical characteristics  described in the users' manual supplied
with the equipment.

WARRANTY

WARRANTY CLAUSES

l

The equipment has a warranty which covers manufacturing and operating
faults for the period indicated on the inside back cover of the user's manual.

l

The warranty is to be considered freight forward and the goods must reach
the address indicated below at customer's expences.

l

Warranty means the substitution or repairing of fault products. Working
hours used for repairing included in the warranty.

l

The estetic and the separable parts are not included in the warranty.

l

The warranty is not extended to equipments which have been subject to
misuse, improper installation, electric discharge or repaired by unauthorized
staff.

Содержание Leonardo 33.6

Страница 1: ...Cod 7D1062 rev 2 0 del 03 99 L E O N A R D O 5 6 E x t e r n a l R S 2 3 2 E x t e r n a l U S B I n t e r n a l I S A C a r d P C C a r d http www digicom it User s Manual User s Manual...

Страница 2: ...8 NT4 0 EXTERNAL USB VERSION 2 7 2 2 3 WINDOWS 95 98 NT4 0 PC VERSION 2 10 2 2 4 MACINTOSH MODEM INSTALLATION FOR ARA OPEN TRANSPORT 2 11 3 MODEM AT COMMAND SET 3 1 3 1 AT COMMAND SET DESCRIPTION 3 1...

Страница 3: ...container or other problems l Objects which produce a strong electtromagnetic field loudspeakers etc l Liquids or chemical corrosive substances GENERAL WARNINGS For all equipment powered directly from...

Страница 4: ...ard like the K56Flex has an unbalanced connection speed It means that you have a connection where data are received at the maximum speed of 56000 bps and sent at the maximum speed of 33 600 bps The un...

Страница 5: ...l 1 Package of Data fax communication software 1 2 PRODUCT FEATURES l Computer speed up to 115 200 bit s l Data modem modes for V 90 K56flex V 34 V 32bis V 32 V 22bis V 22 V 21 V 23 1200 75 l Fax mode...

Страница 6: ...cable to the telephone line See the following picture to connect your modem to the GEO port of your Macintosh and the telephone cable to the telephone line After the cable installation connect the AC...

Страница 7: ...res to connect your modem to the USB port of your Computer and the telephone cable to the telephone socket of the modem After the cable installation switch on your Computer and check that the green LE...

Страница 8: ...rt the modem into the selected slot Secure the bracket with the screw saved earlier Replace the computer cover and plug in your computer Connect the telephone cable to the telephone line For the next...

Страница 9: ...vailable at the time of printing this manual l MACINTOSH Driver ARA Open Transport Make a copy of the Leonardo driver file from the Floppy Disk or the CD ROM to your hard disk in the folder Modem Scri...

Страница 10: ...Run Windows 95 98 NT4 0 2 Select from the START icon Settings Control Pannel Modem Add 3 From the window Install New Modem put a tick in the box Don t detect my modem I will select it from a list and...

Страница 11: ...in the appropriate drive and from the window Install from disk check that the correct driver letter appears showing where your Floppy CD ROM is inserted eg A or D then click the button OK 6 From the l...

Страница 12: ...en clik Next and then Finish Your modem is installed and ready to make the first connection 2 2 2 WINDOWS 95 98 NT4 0 EXTERNAL USB VERSION 1 Start Windows After the modem connection Windows will autom...

Страница 13: ...stallation 3 Select Search for the best driver for your device and press Next 4 In the followinf window select Floppy disk driver 5 Press Next select on the floppy the directory of your operating syst...

Страница 14: ...ation and press Next 7 Press Finish to terminate the installation Your modem is now installed among the modems Windows will use for the connections It will be possible to select it from the list in th...

Страница 15: ...nformation from the Floppy Disk or the CDROM packaged with the modem 1 Run Windows 95 98 NT4 0 2 Select from the START icon Settings Controll Pannel Modem Add From the new window select Modem PCMCIA a...

Страница 16: ...TRANSPORT Be sure you have on your Mac the Open Transport drivers for your modem Install them by copying the files from the ARA OT folder they are on the driver supplied with the modem into the System...

Страница 17: ...2 12 LEONARDO 56 Installation From the bar menu select PPP and then Modem Select the serial port to be used and your modem from the list From the bar menu select PPP and then TCP IP...

Страница 18: ...on 2 13 In the next window select the PPP protocol in the Connect via field The fields concerning the parameters used for the connection in PPP will appear Eventually insert the parameters supplied by...

Страница 19: ...mode by entering an escape sequence The default escape sequence is this must have at least one second before and after being keyed To go back into data mode simply type ATO Data Length Each caracter o...

Страница 20: ...uses the modem to return to the command state after it processes the portion of the dial string preceding the The modem will enter call progress only after an additional dial command is issued without...

Страница 21: ...Automode detection is enabled equivalent to settingAT MS X 1 Note see also AUTOMODE parameter in AT MS command ATO RETURN ON LINE O0 On line state when during connection the modem is in command mode O...

Страница 22: ...IER 16800 54 CARRIER 19200 SHORT EXTENDED 55 CARRIER 21600 56 CARRIER 24000 57 CARRIER 26400 58 CARRIER 28800 78 CARRIER 31200 79 CARRIER 33600 66 COMPRESSION CLASS 5 67 COMPRESSION V42 bis 69 COMPRES...

Страница 23: ...EAK DISCONNECTION Y0 Disable long space disconnect Y1 Enable long space disconnect In non error correction mode or in buffer mode the modem will send a long space of four seconds prior to going on hoo...

Страница 24: ...Some configuration examples l Modem set up with automode enable and connection speed within 300 bps to 56000 bps AT MS 12 1 300 56000 1 0 The modem make the connection at the maximum speed available i...

Страница 25: ...ty disturbed signal AT C CARRIER DETECT OPTION C0 Carrier detect always ON When modem disconnect DCD C109 goes OFF for 1 sec function 109 wink l C1 Carrier detect is ON when remote carrier is present...

Страница 26: ...or It is automatically selected with N command different fron 0 and 1 Q6 Asynchronous with buffer enabled AT N0 AT R C106 R0 In asynchronous mode C106 is controlled according to V25 handshake reccoman...

Страница 27: ...n with the K command In error corrector mode the modem will signal a break through the active error correction protocol giving no indication of the length AT KN SET BREAK CONTROL Controls the response...

Страница 28: ...rror correction mode Forces Q6 N1 Serial interface selected Selects direct mode and is equivalent to M0 Q0 mode operation Forces Q0 N2 Selects reliable error correction mode The modem will first attem...

Страница 29: ...Bm 3 2 S REGISTERS REG RANGE UNIT DEF DESCRIPTION S0 0 255 Ring 0 Ring to answer on S1 0 255 Ring 0 Ring count S2 0 255 ASCII 43 Escape character S3 0 127 ASCII 13 Carriage return character S4 0 127 A...

Страница 30: ...TS30 INACTIVITY DISCONNECTTIMER 0 The modem doesn t disconnect as no data is sent or received 0 255 Sets the length of time in tens of seconds that the modem will stay online before disconnectiong whe...

Страница 31: ...ARRIER Dce CONNECT Dce PROTOCOL Prot CONNECT Dce 2 CONNECT Dte ARQ CARRIER Dce CONNECT Dce ARQ PROTOCOL Prot CONNECT Dte Arq 4 CARRIER Dce CARRIER Dce CARRIER Dce CONNECT Dte PROTOCOL Prot CONNECT Dce...

Страница 32: ...then when the response OK is displayed enter the command AT T0 4 2 LOCAL DIGITAL LOOPBACK TEST CCITT LOOP 2 LOCAL The target of this test is to verify the COM port and the serial cable of your comput...

Страница 33: ...or characters strings or files and they are received from your computer To exit from test condition type the escape sequence and then when the response OK is displayed enter the command AT T0 4 5 REM...

Страница 34: ...ed on the inside back cover of the user s manual It is in conformity with the technical characteristics described in the users manual supplied with the equipment WARRANTY WARRANTY CLAUSES l The equipm...

Страница 35: ......

Отзывы: