XBee connection examples
Connect to the Echo server
Digi XBee3 Cellular LTE-M/NB-IoT Global Smart Modem User Guide
42
Connect to the Echo server
This server echoes back the messages you type.
You may use TCP or UDP, depending on the protocols supported by your network carrier.
Note
For help with debugging, see
.
The following table explains the AT commands that you use in this example.
At
command
Value
Description
IP
(IP
Protocol)
1
TCP: Set the expected transmission mode to TCP communications.
0
UDP: Set the expected transmission mode to UDP communications.
TD
(Text
Delimiter)
D (0x0D)
The text delimiter to be used for Transparent mode, as an ASCII hex
code. No information is sent until this character is entered, unless the
maximum number of characters has been reached. Set to
0
to disable
text delimiter checking. Set to
D
for a carriage return.
DL
(Destination
Address)
52.43.121.77 The target IP address of the echo server.
Note
Some carriers may require whitelisted IP addresses. If this IP is
not whitelisted by your carrier you will not be able to run this example.
DE
(Destination
Port)
0x2329
TCP: The target port number of the TCP echo server.
This port in decimal is 9001.
0x2711
UDP: The target port number of the UDP echo server.
This port in decimal is 10001.
To communicate with the Echo server:
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in
2. Open XCTU and
.
3. Click the
Configuration working mode
button.
4. Select a device from the
Radio Modules
list. XCTU displays the current firmware settings for
that device.
5. To switch to TCP communication, in the
IP
field, select 1 and click the
Write
button
.
6. To enable the XBee Smart Modem to recognize carriage return as a message delimiter, in the
TD
field, type
D
and click the
Write
button.
7. To enter the destination address of the echo server, in the
DL
field, type
52.43.121.77
and click
the
Write
button.
8. To enter the destination IP port number, in the
DE
field, type
2329
and click the
Write
button.
Note
XCTU does not follow the standard hexadecimal numbering convention. The leading 0x is
not needed in XCTU.
Содержание XBee3 XB3M1
Страница 1: ...Digi XBee3 Cellular LTE M NB IoT Smart Modem User Guide ...
Страница 13: ...Digi XBee3 Cellular LTE M NB IoT Global Smart Modem User Guide 13 RF Exposure 250 CE mark Europe 251 ...
Страница 110: ...Antenna recommendations Antenna placement 111 Digi XBee3 Cellular LTE M NB IoT Global Smart Modem User Guide 110 ...