1.

 

Overview

The XBee-PRO XSC RF Modem is a small, low-power solution that uses the XBee-PRO 
XSC (S3B) 900 MHz RF Module in an enclosure to communicate with systems using 
RS-232, RS-485, and USB interfaces. It allows the user to easily make their existing 
wired systems wireless simply by connecting to this product. The XBee-PRO XSC RF 
Modem is a market replacement of Digi’s 9XStream PKG and is able to fully communi-
cate with existing 9XStream RF Modems.   

When a system is connected to the XBee-PRO XSC RF Modem, it can transmit and 
receive data from multiple radios on the same wireless network. This is achieved by 
using Digi’s XBee-Pro XSC (S3B) RF Module. 

This manual is not a comprehensive manual where a full description of the XSC RF 
Modem is given. This manual only covers the interfaces needed to communicate with 
the XSC (S3B) 900 MHz RF Module. For an extensive guide on use of the XSC (S3B) 
900 MHz RF Module, see Appendix A of the XBee-PRO 900 HP/XBee-PRO XSC RF 
Modules Product Manual.

1.1. Features Overview

Long Range Data Integrity

Range

• Indoor/Urban:

 Up to 2000' (610 m)

• Outdoor line-of-sight: 

Up to

 

9 miles (14 

km)

Transmit Power: 

Up to

 

24 dBm (250 mW)

 

(software selectable)

Receiver Sensitivity: 

-109 dBm (@10kbps)

RF Data Rate: 

Up to 20kbps

Advanced Networking & Security

True peer-to-peer (no “master” required) com-
munications

Point-to-point & point-to-multipoint topologies 
supported

Retries and Acknowledgements

7 hopping channels, each with over 65,000 avail-
able network addresses

FHSS (Frequency Hopping Spread Spectrum)

Low Power

Receive Current: 

60 mA (@9V)

Transmit Current: 

140 mA (@9V)

 

Easy-to-Use

No configuration required for out-of-the-box RF 
data communications.

Free X-CTU Software (Testing and configuration 
software)

RS-232 and RS-485 variants configurable via the 
mini USB port. 

Advanced configurations available through stan-
dard AT & binary commands.

Built in RS-232/RS-485/USB interfacing

Small form factor

Software-selectable serial interface baud rates

Support for multiple data formats (parity, start 
and stop bits, etc.)

Free & Unlimited Technical Support

Содержание XBee-PRO XSC RS-232

Страница 1: ...4 or 877 912 3444 Fax 952 912 4952 XBee PRO XSC RS 232 RS 485 USB RF Modem Overview Interfacing Protocol Product Manual For XBee PRO XSC RF Modem Part Numbers XM C91 2P XM C92 2P XM C91 4P XM C92 4P X...

Страница 2: ...e transmitted or reproduced in any form or by any means without the written permission of Digi International Inc XBee PRO XSC RF Modem is a trademark of Digi International Inc Technical Support Phone...

Страница 3: ...10 Wiring Diagrams 11 RS 485 2 wire Operation 12 Pin Signals 13 Wiring Diagram 13 RS 485 4 wire Operation RS 422 Operation 14 Pin Signals 15 Wiring Diagrams 15 RS 485 422 Connection Guidelines 16 USB...

Страница 4: ...he XSC S3B 900 MHz RF Module see Appendix A of the XBee PRO 900 HP XBee PRO XSC RF Modules Product Manual 1 1 Features Overview Long Range Data Integrity Range Indoor Urban Up to 2000 610 m Outdoor li...

Страница 5: ...p to 24 dBm 250 mW software selectable Throughput Data Rate 9 6kbps or 19 2kbps RF Data Rate 10kbps or 20kbps Interface Data Rate 125 65 000 bps Software selectable includes non standard baud rates Re...

Страница 6: ...cate RF modem activity as follows Yellow top LED Serial Data Out to host Green middle Serial Data In from host Red bottom Power TX Indicator Red light is on when powered off briefly during RF transmis...

Страница 7: ...S485 1 04a RSSI LEDs Not applicable to XBee PRO XSC RF Modem 1 04b I O Power LEDs LEDs indicate RF modem activity as follows Yellow top LED Serial Data Out to host Green middle Serial Data In from hos...

Страница 8: ...06a RSSI LEDs Not applicable to XBee PRO XSC RF Modem 1 06b I O Power LEDs LEDs indicate RF modem activity as follows Yellow top LED Serial Data Out to host Green middle Serial Data In from host Red...

Страница 9: ...RO XSC RS 232 RS 485 USB RF Modem Product Manual 2013 Digi International Inc 9 1 4 RF Modem Symbols The following symbols are found on top of the RF Modem The description of the symbol is next to the...

Страница 10: ...default this pin is not used To configure this pin to support Sleep Mode refer to the Sleep Mode SM Command and PW Command Sections 5 GND Ground Signal Ground 6 DSR Data Set Ready Connected to DCD pi...

Страница 11: ...Inc 11 2 1 2 Wiring Diagrams Figure 2 02 RS 232 Device DTE Device male DB 9 connector wired to a DCE RF modem female DB 9 XBee PRORF Modem DCE RF Modem to an DCE RS 232 Device Figure 2 03 DCE RF Modem...

Страница 12: ...cable should be plugged into the modem to reconfigure it The reconfiguration can be done by using Digi s X CTU With the USB plugged in open X CTU and select the Com port of the USB Select the Termina...

Страница 13: ...2 2 2 Wiring Diagram Figure 2 06 RF Modem in an RS 485 2 wire half duplex Phoenix 6 Pin RS 485 Name Description Implementation 1 TX RX Negative Data Line Transmit serial data to and from the RF modem...

Страница 14: ...econfigure it The reconfiguration can be done by using Digi s X CTU With the USB plugged in open X CTU and select the Com port of the USB Select the Terminal tab and type The system will respond with...

Страница 15: ...an RS 485 4 wire environment Phoenix 6 Pin RS 485 Name Description Implementation 1 TX Transmit Positive Serial data sent from RF modem 2 TX Transmit Negative Data Line Serial data received by the RF...

Страница 16: ...for the positive and negative data lines An Ethernet cable is good for twisted pairs When using Ethernet twisted pair cabling Select wires so that TX and TX are connected to a twisted pair Likewise s...

Страница 17: ...plementation 1 VBUS Power Power the RF modem 2 D Negative Data Line Transmit data to and from the RF modem 3 D Positive Data Line Transmit data to and from the RF modem 4 GND Ground Signal Ground Pin...

Страница 18: ...ection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions...

Страница 19: ...be used at distances closer than 20cm to all persons the device may be required to undergo SAR testing Co location with other transmitting antennas closer than 20cm should be avoided RF Exposure This...

Страница 20: ...2 1 dBi Fixed 0dB A09 F3 Fiberglass Base RPSMA 3 1 dBi Fixed 0dB A09 F4 Fiberglass Base RPSMA 4 1 dBi Fixed 0dB A09 F5 Fiberglass Base RPSMA 5 1 dBi Fixed 0dB A09 F6 Fiberglass Base RPSMA 6 1 dBi Fixe...

Страница 21: ...0dB A09 QSPM 3 3 Straight screw Permanent 1 9 dBi Fixed Mobile 0dB A09 QAPM 3 3 Articulated screw Permanent 1 9 dBi Fixed Mobile 0dB A09 QAPM 3H 3 Articulated screw Permanent 1 9 dBi Fixed Mobile 0dB...

Страница 22: ...Conform ment la r glementation d Industrie Canada le pr sent metteur radio peut fonctionner avec une antenne d un type et d un gain maximal ou inf rieur approuv pour l metteur par Industrie Canada Dan...

Страница 23: ...TY OR FITNESS FOR A PARTICULAR PUR POSE IN NO EVENT SHALL DIGI ITS SUPPLIERS OR LICENSORS BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT FOR ANY LOSS OF USE LOSS OF TIME INCONVEN...

Отзывы: